摘要
We report on a non-enzymatic hydrogen peroxide (H2O2) sensor which makes use of a nanocomposite consisting of platinum nanoparticles (PtNPs) and chitosan-encapsulated graphite (graphite-CS). The composite was prepared by sonication of pristine graphite in chitosan (CS) in 5 % acetic acid. The PtNP decorated graphite-CS (graphite-CS/PtNPs) composite was prepared by electrodeposition of PtNPs on the graphite-CS modified glassy carbon electrode. The graphite-CS/PtNP composite was characterized by scanning electron microscopy, elemental analysis and FTIR spectroscopy. The modified electrode displays an enhanced reduction peak current for H2O2 when compared with electrodes modified with graphite/PtNPs and PtNPs. The modified electrode exhibits excellent electrocatalytic activity towards the reduction of H2O2, and the amperometric response is linear over the concentration range from 0.25 to 2890 μM. The sensitivity and the detection limit are 0.465 μA⋅μM‾1 ⋅ cm‾2 and 66 nM, respectively. The sensor shows fast response (3 s) in detecting H2O2. It is also highly selective in the presence of potentially interfering compounds, and may therefore be used as a feasible platform for sensing H2O2 in real samples.
引用
收藏
页码:2861 / 2869
页数:8
相关论文
共 50 条
  • [1] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a composite consisting of chitosanaEuroencapsulated graphite and platinum nanoparticles
    Chen, Tse-Wei
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    [J]. MICROCHIMICA ACTA, 2016, 183 (11) : 2861 - 2869
  • [2] Non-enzymatic sensing of glucose and hydrogen peroxide using a glassy carbon electrode modified with a nanocomposite consisting of nanoporous copper, carbon black and nafion
    Ling Mei
    Pengcheng Zhang
    Jiyun Chen
    Dandan Chen
    Ying Quan
    Ning Gu
    Genhua Zhang
    Rongjing Cui
    [J]. Microchimica Acta, 2016, 183 : 1359 - 1365
  • [3] Non-enzymatic sensing of glucose and hydrogen peroxide using a glassy carbon electrode modified with a nanocomposite consisting of nanoporous copper, carbon black and nafion
    Mei, Ling
    Zhang, Pengcheng
    Chen, Jiyun
    Chen, Dandan
    Quan, Ying
    Gu, Ning
    Zhang, Genhua
    Cui, Rongjing
    [J]. MICROCHIMICA ACTA, 2016, 183 (04) : 1359 - 1365
  • [4] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    [J]. MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395
  • [5] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Huaan Zhong
    Ruo Yuan
    Yaqin Chai
    Yu Zhang
    Chengyan Wang
    Feng Jia
    [J]. Microchimica Acta, 2012, 176 : 389 - 395
  • [6] Electroless deposition of Gold-Platinum Core@Shell Nanoparticles on Glassy Carbon Electrode for Non-Enzymatic Hydrogen Peroxide sensing
    Gowthaman, N. S. K.
    John, S. Abraham
    [J]. JOURNAL OF CHEMICAL SCIENCES, 2016, 128 (03) : 331 - 338
  • [7] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a nanocomposite made from carbon nanotubes and molybdenum disulfide
    Lin, Yuping
    Chen, Xian
    Lin, Youxiu
    Zhou, Qian
    Tang, Dianping
    [J]. MICROCHIMICA ACTA, 2015, 182 (9-10) : 1803 - 1809
  • [8] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a nanocomposite made from carbon nanotubes and molybdenum disulfide
    Yuping Lin
    Xian Chen
    Youxiu Lin
    Qian Zhou
    Dianping Tang
    [J]. Microchimica Acta, 2015, 182 : 1803 - 1809
  • [9] Non-enzymatic sensor based on a glassy carbon electrode modified with Ag nanoparticles/polyaniline/halloysite nanotube nanocomposites for hydrogen peroxide sensing
    Yang, Ziyin
    Zheng, Xiaohui
    Zheng, Jianbin
    [J]. RSC ADVANCES, 2016, 6 (63) : 58329 - 58335
  • [10] Electroless deposition of Gold-Platinum Core@Shell Nanoparticles on Glassy Carbon Electrode for Non-Enzymatic Hydrogen Peroxide sensing#
    N S K GOWTHAMAN
    S ABRAHAM JOHN
    [J]. Journal of Chemical Sciences, 2016, 128 : 331 - 338