Non-enzymatic determination of hydrogen peroxide in milk samples using Graphite oxide/Nafion/Azure A modified electrode

被引:0
|
作者
Chandrasekaran Priya
Sriraman Anuja
Mani Devendiran
Rajendran Suresh Babu
Sangilimuthu Sriman Narayanan
机构
[1] University of Madras,Department of Analytical Chemistry
[2] Guindy Campus,Department of Chemistry
[3] Loyola College,Laboratory of Experimental and Applied Physics
[4] Centro Federal de Educação Tecnológica Celso Suckow da Fonseca,undefined
来源
Ionics | 2024年 / 30卷
关键词
Amperometry; Azure A; Hydrogen peroxide, modified electrode, cyclic voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:2869 / 2880
页数:11
相关论文
共 50 条
  • [1] Non-enzymatic determination of hydrogen peroxide in milk samples using Graphite oxide/Nafion/Azure A modified electrode
    Priya, Chandrasekaran
    Anuja, Sriraman
    Devendiran, Mani
    Babu, Rajendran Suresh
    Narayanan, Sangilimuthu Sriman
    [J]. IONICS, 2024, 30 (05) : 2869 - 2880
  • [2] Electrochemical behavior of Azure A/gold nanoclusters modified electrode and its application as non-enzymatic hydrogen peroxide sensor
    Priya, C.
    Sivasankari, G.
    Narayanan, S. Sriman
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2012, 97 : 90 - 96
  • [3] Non-enzymatic hydrogen peroxide sensor using an electrode modified with iron pentacyanonitrosylferrate nanoparticles
    Habib Razmi
    Rahim Mohammad-Rezaei
    [J]. Microchimica Acta, 2010, 171 : 257 - 265
  • [4] Non-enzymatic hydrogen peroxide sensor using an electrode modified with iron pentacyanonitrosylferrate nanoparticles
    Razmi, Habib
    Mohammad-Rezaei, Rahim
    [J]. MICROCHIMICA ACTA, 2010, 171 (3-4) : 257 - 265
  • [5] Graphene oxide-Cu(II) composite electrode for non-enzymatic determination of hydrogen peroxide
    Muralikrishna, S.
    Cheunkar, Sarawut
    Lertanantawong, Benchaporn
    Ramakrishnappa, T.
    Nagaraju, D. H.
    Surareungchai, Werasak
    Balakrishna, R. Geetha
    Reddy, K. Ramakrishna
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 776 : 59 - 65
  • [6] Non-enzymatic amperometric detection of hydrogen peroxide in human blood serum samples using a modified silver nanowire electrode
    Thirumalraj, Balamurugan
    Zhao, Duo-Han
    Chen, Shen-Ming
    Palanisamy, Selvakumar
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2016, 470 : 117 - 122
  • [7] A non-enzymatic hydrogen peroxide sensor based on a glassy carbon electrode modified with cuprous oxide and nitrogen-doped graphene in a nafion matrix
    Jiang, Bin-Bin
    Wei, Xian-Wen
    Wu, Fang-Hui
    Wu, Kong-Lin
    Chen, Le
    Yuan, Guo-Zan
    Dong, Chao
    Ye, Yin
    [J]. MICROCHIMICA ACTA, 2014, 181 (11-12) : 1463 - 1470
  • [8] A non-enzymatic hydrogen peroxide sensor based on a glassy carbon electrode modified with cuprous oxide and nitrogen-doped graphene in a nafion matrix
    Bin-Bin Jiang
    Xian-Wen Wei
    Fang-Hui Wu
    Kong-Lin Wu
    Le Chen
    Guo-Zan Yuan
    Chao Dong
    Yin Ye
    [J]. Microchimica Acta, 2014, 181 : 1463 - 1470
  • [9] Non-enzymatic detection of hydrogen peroxide based on Fenton-type reaction on poly(azure A)-chitosan/Cu modified electrode
    Liu, Tong
    Luo, Yiqun
    Wang, Wen
    Kong, Liyan
    Zhu, Jiaming
    Tan, Liang
    [J]. ELECTROCHIMICA ACTA, 2015, 182 : 742 - 750
  • [10] Crumpled Graphene/Poly (azure I) Modified Electrode for Non-enzymatic Detection of Hydrogen Peroxide Secreted from Tumor Cells
    Zhang, Keying
    Zhang, Ziqiang
    Ma, Shangshang
    Cheng, Deshun
    Fan, Mengdi
    Zhou, Xinyu
    Li, Fajun
    Zhang, Na
    [J]. ANALYTICAL SCIENCES, 2021, 37 (10) : 1367 - 1372