Non-enzymatic detection of hydrogen peroxide based on Fenton-type reaction on poly(azure A)-chitosan/Cu modified electrode

被引:18
|
作者
Liu, Tong [1 ]
Luo, Yiqun [1 ]
Wang, Wen [1 ]
Kong, Liyan [1 ]
Zhu, Jiaming [1 ]
Tan, Liang [1 ]
机构
[1] Hunan Normal Univ, Coll Chem & Chem Engn, Minist Educ China, Key Lab Chem Biol & Tradit Chinese Med Res, Changsha 410081, Hunan, Peoples R China
关键词
Composite film modified electrode; Fenton-type reaction; Electrocatalysis; Hydrogen peroxide; Non-enzymatic sensor; KINETIC-SPECTROPHOTOMETRIC DETERMINATION; ENHANCED ELECTROCATALYTIC REDUCTION; CARBON NANOTUBES; TRACE AMOUNTS; PYROGALLOL RED; OXIDATION; NANOPARTICLES; COPPER(II); CHITOSAN; SENSOR;
D O I
10.1016/j.electacta.2015.09.063
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work, a sensitive electrochemical method for the detection of H2O2 was proposed based on Fenton-type reaction on the electrode surface. A glassy carbon electrode modified with poly(azure A) (PAA), chitosan (CS) and copper ions, displaying a good electrochemical activity, was fabricated by cyclic voltammetry and the adsorption of Cu2+. Scanning electron microscopy-Energy dispersive spectroscopy analysis, infrared and Raman spectral characterization and XPS measurement showed the stable complexation of Cu2+ with the PAA-CS film. Hydroxyl radicals derived from the Fenton-type reaction between Cu2+ and H2O2 could effectively oxidize poly(azure A), leading to the great reduction-current change of the dye polymer in the electrode process. Under the optimized conditions, the fabricated electrode displayed a linear response in the H2O2 concentration range from 0.002 to 0.5 mM and that from 2.56 to 25.0 mM with a detection limit of 0.7 mM estimated at a signal-to-noise ratio of 3. The good analytical performance including low detection limit, fast response time, low cost, good anti-interference performance, satisfying stability, acceptable repeatability and reliable reproducibility were found from the proposed amperometric sensor, suggesting that the current work could provide a feasible approach for the non-enzymatic H2O2 detection. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:742 / 750
页数:9
相关论文
共 50 条
  • [1] Crumpled Graphene/Poly (azure I) Modified Electrode for Non-enzymatic Detection of Hydrogen Peroxide Secreted from Tumor Cells
    Zhang, Keying
    Zhang, Ziqiang
    Ma, Shangshang
    Cheng, Deshun
    Fan, Mengdi
    Zhou, Xinyu
    Li, Fajun
    Zhang, Na
    [J]. ANALYTICAL SCIENCES, 2021, 37 (10) : 1367 - 1372
  • [2] Crumpled Graphene/Poly (azure I) Modified Electrode for Non-enzymatic Detection of Hydrogen Peroxide Secreted from Tumor Cells
    Keying Zhang
    Ziqiang Zhang
    Shangshang Ma
    Deshun Cheng
    Mengdi Fan
    Xinyu Zhou
    Fajun Li
    Na Zhang
    [J]. Analytical Sciences, 2021, 37 : 1367 - 1372
  • [3] Electrochemical behavior of Azure A/gold nanoclusters modified electrode and its application as non-enzymatic hydrogen peroxide sensor
    Priya, C.
    Sivasankari, G.
    Narayanan, S. Sriman
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2012, 97 : 90 - 96
  • [4] Non-enzymatic determination of hydrogen peroxide in milk samples using Graphite oxide/Nafion/Azure A modified electrode
    Priya, Chandrasekaran
    Anuja, Sriraman
    Devendiran, Mani
    Babu, Rajendran Suresh
    Narayanan, Sangilimuthu Sriman
    [J]. IONICS, 2024, 30 (05) : 2869 - 2880
  • [5] Non-enzymatic determination of hydrogen peroxide in milk samples using Graphite oxide/Nafion/Azure A modified electrode
    Chandrasekaran Priya
    Sriraman Anuja
    Mani Devendiran
    Rajendran Suresh Babu
    Sangilimuthu Sriman Narayanan
    [J]. Ionics, 2024, 30 : 2869 - 2880
  • [6] Non-enzymatic hydrogen peroxide sensor based on palladium-decorated poly(thionine) modified glassy carbon electrode
    Celebi, Mutlu Sonmez
    Kara, Songul Kirlak
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2024, 71 (05) : 482 - 492
  • [7] A simple non-enzymatic hydrogen peroxide sensor using gold nanoparticles-graphene-chitosan modified electrode
    Jia, Ningming
    Huang, Baozhen
    Chen, Lina
    Tan, Liang
    Yao, Shouzhuo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 195 : 165 - 170
  • [8] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Yin, Guang
    Xing, Ling
    Ma, Xiu-Ju
    Wan, Jun
    [J]. CHEMICAL PAPERS, 2014, 68 (04): : 435 - 441
  • [9] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Guang Yin
    Ling Xing
    Xiu-Ju Ma
    Jun Wan
    [J]. Chemical Papers, 2014, 68 : 435 - 441
  • [10] Non-enzymatic detection of glucose using poly(azure A)-nickel
    Liu, Tong
    Luo, Yiqun
    Zhu, Jiaming
    Kong, Liyan
    Wang, Wen
    Tan, Liang
    [J]. TALANTA, 2016, 156 : 134 - 140