Crumpled Graphene/Poly (azure I) Modified Electrode for Non-enzymatic Detection of Hydrogen Peroxide Secreted from Tumor Cells

被引:2
|
作者
Zhang, Keying [1 ,2 ]
Zhang, Ziqiang [1 ]
Ma, Shangshang [1 ]
Cheng, Deshun [1 ]
Fan, Mengdi [1 ]
Zhou, Xinyu [1 ]
Li, Fajun [1 ]
Zhang, Na [1 ]
机构
[1] Suzhou Univ, Sch Chem & Chem Engn, Anhui Key Lab Spin Electron & Nanomat, Suzhou 234000, Anhui, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Transducer Technol, Shanghai 200050, Peoples R China
关键词
Graphene; hydrogen peroxide; poly (azure I); modified electrode; ELECTROCHEMICAL DETECTION; H2O2; DETECTION; OXIDE; ENZYME; NANOCOMPOSITES; NANOPARTICLES; FABRICATION; NANOFIBERS;
D O I
10.2116/analsci.21P003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrogen peroxide (H2O2), an important representatives of reactive oxygen species, its aberrant expression is related to many diseases, including cancers. Therefore, it is very significant to design a reliable method for the real-time detection of endogenous H2O2. Herein, we describe preparing a poly (azure I)/crumpled graphene (cGN) modified electrode by an electro-polymerization method. The results showed that this electrode presented obvious electrocatalytic effect on the reduction of H2O2. Amperometric method was employed to monitor H2O2, and the amperometric response exhibited a good linear relationship with its concentration in the range of 8.0 x 10(-6) - 1.25 x 10(-3) mol/L; the detection limit reached to 6.7 x 10(-7) mol/L (S/N = 3). Furthermore, this modified also displayed good selectivity, long-term stability and a high anti-interference ability. Excitingly, the established method could be successfully used to detect H2O2 in human serum samples, and measured H2O2 secreted from living MCF-7 cells. It could have potential use in cancer diagnosis.
引用
收藏
页码:1367 / 1372
页数:6
相关论文
共 50 条
  • [1] Crumpled Graphene/Poly (azure I) Modified Electrode for Non-enzymatic Detection of Hydrogen Peroxide Secreted from Tumor Cells
    Keying Zhang
    Ziqiang Zhang
    Shangshang Ma
    Deshun Cheng
    Mengdi Fan
    Xinyu Zhou
    Fajun Li
    Na Zhang
    [J]. Analytical Sciences, 2021, 37 : 1367 - 1372
  • [2] Non-enzymatic detection of hydrogen peroxide based on Fenton-type reaction on poly(azure A)-chitosan/Cu modified electrode
    Liu, Tong
    Luo, Yiqun
    Wang, Wen
    Kong, Liyan
    Zhu, Jiaming
    Tan, Liang
    [J]. ELECTROCHIMICA ACTA, 2015, 182 : 742 - 750
  • [3] Electrochemical behavior of Azure A/gold nanoclusters modified electrode and its application as non-enzymatic hydrogen peroxide sensor
    Priya, C.
    Sivasankari, G.
    Narayanan, S. Sriman
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2012, 97 : 90 - 96
  • [4] Non-enzymatic determination of hydrogen peroxide in milk samples using Graphite oxide/Nafion/Azure A modified electrode
    Priya, Chandrasekaran
    Anuja, Sriraman
    Devendiran, Mani
    Babu, Rajendran Suresh
    Narayanan, Sangilimuthu Sriman
    [J]. IONICS, 2024, 30 (05) : 2869 - 2880
  • [5] Non-enzymatic determination of hydrogen peroxide in milk samples using Graphite oxide/Nafion/Azure A modified electrode
    Chandrasekaran Priya
    Sriraman Anuja
    Mani Devendiran
    Rajendran Suresh Babu
    Sangilimuthu Sriman Narayanan
    [J]. Ionics, 2024, 30 : 2869 - 2880
  • [6] Biosensor based on bimetallic/graphene composite for non-enzymatic detection of hydrogen peroxide in living tumor cells
    Zhang, Qiyan
    Guo, Lianshan
    Li, Haoyu
    Huang, Jianfeng
    Li, Zhengzhao
    Hong, Wenzhong
    Wang, Jian
    Bai, Zhihao
    Zhu, Jianmeng
    [J]. BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2023, 70 (03) : 1024 - 1034
  • [7] Non-enzymatic detection of hydrogen peroxide using a functionalized three-dimensional graphene electrode
    Xi, Fengna
    Zhao, Dongjiao
    Wang, Xuewan
    Chen, Peng
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2013, 26 : 81 - 84
  • [8] Non-enzymatic detection of glucose using poly(azure A)-nickel
    Liu, Tong
    Luo, Yiqun
    Zhu, Jiaming
    Kong, Liyan
    Wang, Wen
    Tan, Liang
    [J]. TALANTA, 2016, 156 : 134 - 140
  • [9] A simple non-enzymatic hydrogen peroxide sensor using gold nanoparticles-graphene-chitosan modified electrode
    Jia, Ningming
    Huang, Baozhen
    Chen, Lina
    Tan, Liang
    Yao, Shouzhuo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 195 : 165 - 170
  • [10] Electrochemically Prepared Three-dimensional Porous Nitrogen-doped Graphene Modified Electrode for Non-enzymatic Detection of Hydrogen Peroxide
    Qi, Yamin
    Bai, Jie
    Ding, Xiaoteng
    Zhang, Hui-Min
    [J]. ELECTROANALYSIS, 2017, 29 (09) : 2083 - 2089