Electrochemical behavior of Azure A/gold nanoclusters modified electrode and its application as non-enzymatic hydrogen peroxide sensor

被引:34
|
作者
Priya, C. [1 ]
Sivasankari, G. [1 ]
Narayanan, S. Sriman [1 ,2 ]
机构
[1] Univ Madras, Dept Analyt Chem, Madras 600025, Tamil Nadu, India
[2] Univ Madras, Natl Ctr Nanosci & Nanotechnol, Madras 600025, Tamil Nadu, India
关键词
Non-enzymatic; Azure A; Gold; Nanoclusters; H2O2; HORSERADISH-PEROXIDASE; GOLD NANOPARTICLES; MICROELECTRODE-ARRAYS; CARBON; VOLTAMMETRY; H2O2; FILM; DOPAMINE; OXIDASE; MATRIX;
D O I
10.1016/j.colsurfb.2012.04.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel non-enzymatic hydrogen peroxide sensor was developed using Azure A/gold nanoclusters modified graphite electrode. The method of preparation of Azure A/gold nanoclusters was simple and it was characterized by UV-visible spectroscopy, field emission scanning electron microscopy (FESEM) and confocal Raman microscopy. The electrochemical properties of Azure A/gold nanoclusters modified graphite electrode was characterized by cyclic voltammetry. In 0.1 M H2SO4 the modified electrode showed redox peaks which correspond to the redox behavior of gold nanoparticle. In 0.1 M PBS the modified electrode exhibited well defined redox peaks with the formal potential of -0.253 V which is analogous to the redox reaction of Azure A. The results have shown that the gold nanoclusters has reduced the formal potential of Azure A and enhanced the current due to the fast charge transfer kinetics. Also the modified electrode showed an enhanced electrocatalytic activity towards the reduction of H2O2 in the concentration range of 3.26 x 10(-6) M to 3.2 x 10(-3) M with a detection limit of 1.08 x 10(-6) M (S/N = 3). The proposed electrode exhibited good stability and reproducibility, and it has the potential application as a sensor for other biologically significant compounds. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 96
页数:7
相关论文
共 50 条
  • [1] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Yin, Guang
    Xing, Ling
    Ma, Xiu-Ju
    Wan, Jun
    [J]. CHEMICAL PAPERS, 2014, 68 (04): : 435 - 441
  • [2] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Guang Yin
    Ling Xing
    Xiu-Ju Ma
    Jun Wan
    [J]. Chemical Papers, 2014, 68 : 435 - 441
  • [3] Non-enzymatic hydrogen peroxide sensor based on a gold electrode modified with granular cuprous oxide nanowires
    Yan, Zhongke
    Zhao, Jianwei
    Qin, Lirong
    Mu, Fan
    Wang, Ping
    Feng, Xining
    [J]. MICROCHIMICA ACTA, 2013, 180 (1-2) : 145 - 150
  • [4] Non-enzymatic hydrogen peroxide sensor based on a gold electrode modified with granular cuprous oxide nanowires
    Zhongke Yan
    Jianwei Zhao
    Lirong Qin
    Fan Mu
    Ping Wang
    Xining Feng
    [J]. Microchimica Acta, 2013, 180 : 145 - 150
  • [5] Nanoporous gold as non-enzymatic sensor for hydrogen peroxide
    Meng, Fanhui
    Yan, Xiuling
    Liu, Jianguo
    Gu, Jun
    Zou, Zhigang
    [J]. ELECTROCHIMICA ACTA, 2011, 56 (12) : 4657 - 4662
  • [6] A simple non-enzymatic hydrogen peroxide sensor using gold nanoparticles-graphene-chitosan modified electrode
    Jia, Ningming
    Huang, Baozhen
    Chen, Lina
    Tan, Liang
    Yao, Shouzhuo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 195 : 165 - 170
  • [7] Non-enzymatic hydrogen peroxide sensor using an electrode modified with iron pentacyanonitrosylferrate nanoparticles
    Habib Razmi
    Rahim Mohammad-Rezaei
    [J]. Microchimica Acta, 2010, 171 : 257 - 265
  • [8] Non-enzymatic hydrogen peroxide sensor using an electrode modified with iron pentacyanonitrosylferrate nanoparticles
    Razmi, Habib
    Mohammad-Rezaei, Rahim
    [J]. MICROCHIMICA ACTA, 2010, 171 (3-4) : 257 - 265
  • [9] Non-enzymatic determination of hydrogen peroxide in milk samples using Graphite oxide/Nafion/Azure A modified electrode
    Priya, Chandrasekaran
    Anuja, Sriraman
    Devendiran, Mani
    Babu, Rajendran Suresh
    Narayanan, Sangilimuthu Sriman
    [J]. IONICS, 2024, 30 (05) : 2869 - 2880
  • [10] Non-enzymatic determination of hydrogen peroxide in milk samples using Graphite oxide/Nafion/Azure A modified electrode
    Chandrasekaran Priya
    Sriraman Anuja
    Mani Devendiran
    Rajendran Suresh Babu
    Sangilimuthu Sriman Narayanan
    [J]. Ionics, 2024, 30 : 2869 - 2880