Non-enzymatic hydrogen peroxide sensor based on a gold electrode modified with granular cuprous oxide nanowires

被引:2
|
作者
Zhongke Yan
Jianwei Zhao
Lirong Qin
Fan Mu
Ping Wang
Xining Feng
机构
[1] Southwest University,School of Physical Science and Technology
来源
Microchimica Acta | 2013年 / 180卷
关键词
Template method; Cu; O; Nanowires; Hydrogen peroxide; Sensor;
D O I
暂无
中图分类号
学科分类号
摘要
Granular nanowires with a diameter of about 60 nm were fabricated from cuprous oxide (Cu2O) by an electrochemical method using anodic aluminium oxide as the template. A non-enzymatic sensor for hydrogen peroxide (H2O2) was then developed on the basis of a gold electrode modified with Cu2O nanowires and Nafion. The resulting sensor enables the determination of H2O2 with a sensitivity of 745 μA mM−1 cm−2, over a wide linear range (0.25 μM to 5.0 mM), and with a low detection limit (0.12 μM). The results demonstrate that the use of such granular nanowires provides a promising tool for the design of non-enzymatic chemical sensors.
引用
收藏
页码:145 / 150
页数:5
相关论文
共 50 条
  • [1] Non-enzymatic hydrogen peroxide sensor based on a gold electrode modified with granular cuprous oxide nanowires
    Yan, Zhongke
    Zhao, Jianwei
    Qin, Lirong
    Mu, Fan
    Wang, Ping
    Feng, Xining
    [J]. MICROCHIMICA ACTA, 2013, 180 (1-2) : 145 - 150
  • [2] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Yin, Guang
    Xing, Ling
    Ma, Xiu-Ju
    Wan, Jun
    [J]. CHEMICAL PAPERS, 2014, 68 (04): : 435 - 441
  • [3] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Guang Yin
    Ling Xing
    Xiu-Ju Ma
    Jun Wan
    [J]. Chemical Papers, 2014, 68 : 435 - 441
  • [4] A non-enzymatic hydrogen peroxide sensor based on a glassy carbon electrode modified with cuprous oxide and nitrogen-doped graphene in a nafion matrix
    Jiang, Bin-Bin
    Wei, Xian-Wen
    Wu, Fang-Hui
    Wu, Kong-Lin
    Chen, Le
    Yuan, Guo-Zan
    Dong, Chao
    Ye, Yin
    [J]. MICROCHIMICA ACTA, 2014, 181 (11-12) : 1463 - 1470
  • [5] A non-enzymatic hydrogen peroxide sensor based on a glassy carbon electrode modified with cuprous oxide and nitrogen-doped graphene in a nafion matrix
    Bin-Bin Jiang
    Xian-Wen Wei
    Fang-Hui Wu
    Kong-Lin Wu
    Le Chen
    Guo-Zan Yuan
    Chao Dong
    Yin Ye
    [J]. Microchimica Acta, 2014, 181 : 1463 - 1470
  • [6] Nanoporous gold as non-enzymatic sensor for hydrogen peroxide
    Meng, Fanhui
    Yan, Xiuling
    Liu, Jianguo
    Gu, Jun
    Zou, Zhigang
    [J]. ELECTROCHIMICA ACTA, 2011, 56 (12) : 4657 - 4662
  • [7] A non-enzymatic sensor for hydrogen peroxide based on polyaniline, multiwalled carbon nanotubes and gold nanoparticles modified Au electrode
    Narang, Jagriti
    Chauhan, Nidhi
    Pundir, C. S.
    [J]. ANALYST, 2011, 136 (21) : 4460 - 4466
  • [8] Electrochemical behavior of Azure A/gold nanoclusters modified electrode and its application as non-enzymatic hydrogen peroxide sensor
    Priya, C.
    Sivasankari, G.
    Narayanan, S. Sriman
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2012, 97 : 90 - 96
  • [9] A simple non-enzymatic hydrogen peroxide sensor using gold nanoparticles-graphene-chitosan modified electrode
    Jia, Ningming
    Huang, Baozhen
    Chen, Lina
    Tan, Liang
    Yao, Shouzhuo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 195 : 165 - 170
  • [10] Preparation and performance of non-enzymatic glucose sensor electrode based on nanometer cuprous oxide
    Yu, Xiaojiao
    Zhang, Jie
    Tang, Xiyan
    Wei, Yuchen
    Kou, Song
    Niu, Jinfen
    Yao, Binghua
    [J]. NANOMATERIALS AND NANOTECHNOLOGY, 2018, 8