Electrochemical behavior of Azure A/gold nanoclusters modified electrode and its application as non-enzymatic hydrogen peroxide sensor

被引:34
|
作者
Priya, C. [1 ]
Sivasankari, G. [1 ]
Narayanan, S. Sriman [1 ,2 ]
机构
[1] Univ Madras, Dept Analyt Chem, Madras 600025, Tamil Nadu, India
[2] Univ Madras, Natl Ctr Nanosci & Nanotechnol, Madras 600025, Tamil Nadu, India
关键词
Non-enzymatic; Azure A; Gold; Nanoclusters; H2O2; HORSERADISH-PEROXIDASE; GOLD NANOPARTICLES; MICROELECTRODE-ARRAYS; CARBON; VOLTAMMETRY; H2O2; FILM; DOPAMINE; OXIDASE; MATRIX;
D O I
10.1016/j.colsurfb.2012.04.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel non-enzymatic hydrogen peroxide sensor was developed using Azure A/gold nanoclusters modified graphite electrode. The method of preparation of Azure A/gold nanoclusters was simple and it was characterized by UV-visible spectroscopy, field emission scanning electron microscopy (FESEM) and confocal Raman microscopy. The electrochemical properties of Azure A/gold nanoclusters modified graphite electrode was characterized by cyclic voltammetry. In 0.1 M H2SO4 the modified electrode showed redox peaks which correspond to the redox behavior of gold nanoparticle. In 0.1 M PBS the modified electrode exhibited well defined redox peaks with the formal potential of -0.253 V which is analogous to the redox reaction of Azure A. The results have shown that the gold nanoclusters has reduced the formal potential of Azure A and enhanced the current due to the fast charge transfer kinetics. Also the modified electrode showed an enhanced electrocatalytic activity towards the reduction of H2O2 in the concentration range of 3.26 x 10(-6) M to 3.2 x 10(-3) M with a detection limit of 1.08 x 10(-6) M (S/N = 3). The proposed electrode exhibited good stability and reproducibility, and it has the potential application as a sensor for other biologically significant compounds. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 96
页数:7
相关论文
共 50 条
  • [21] Copper oxide nanoparticles and ionic liquid modified carbon electrode for the non-enzymatic electrochemical sensing of hydrogen peroxide
    Ping, Jianfeng
    Ru, Shiping
    Fan, Kai
    Wu, Jian
    Ying, Yibin
    [J]. MICROCHIMICA ACTA, 2010, 171 (1-2) : 117 - 123
  • [22] Copper oxide nanoparticles and ionic liquid modified carbon electrode for the non-enzymatic electrochemical sensing of hydrogen peroxide
    Ping, Jianfeng
    Ru, Shiping
    Fan, Kai
    Wu, Jian
    Ying, Yibin
    [J]. Microchimica Acta, 2010, 171 (02) : 117 - 123
  • [23] Copper oxide nanoparticles and ionic liquid modified carbon electrode for the non-enzymatic electrochemical sensing of hydrogen peroxide
    Jianfeng Ping
    Shiping Ru
    Kai Fan
    Jian Wu
    Yibin Ying
    [J]. Microchimica Acta, 2010, 171 : 117 - 123
  • [24] Electrosynthesis of gold nanoparticles/porous GaN electrode for non-enzymatic hydrogen peroxide detection
    Zhang, Miao-Rong
    Chen, Xue-Qing
    Pan, Ge-Bo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 142 - 147
  • [25] Non-enzymatic amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with gold nanoparticles deposited on CVD-grown graphene
    Yawen Yuan
    Yiqun Zheng
    Jinglei Liu
    Hua Wang
    Shifeng Hou
    [J]. Microchimica Acta, 2017, 184 : 4723 - 4729
  • [26] Non-enzymatic amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with gold nanoparticles deposited on CVD-grown graphene
    Yuan, Yawen
    Zheng, Yiqun
    Liu, Jinglei
    Wang, Hua
    Hou, Shifeng
    [J]. MICROCHIMICA ACTA, 2017, 184 (12) : 4723 - 4729
  • [27] A Non-enzymatic Hydrogen Peroxide Photoelectrochemical Sensor Based on a BiVO4 Electrode
    Liu, Min
    Yu, Yu-Xiang
    Zhang, Wei-De
    [J]. ELECTROANALYSIS, 2017, 29 (01) : 305 - 311
  • [28] Electrochemical sensor for the non-enzymatic reduction of hydrogen peroxide and oxidation of gallic acid using a polyamidoblack-10B (PAB)-modified electrode
    Manoranjitham, J. Jayadevi
    Narayanan, S. Sriman
    [J]. NEW JOURNAL OF CHEMISTRY, 2022, 46 (31) : 14979 - 14991
  • [29] Non-enzymatic hydrogen peroxide detection using gold nanoclusters-modified phosphorus incorporated tetrahedral amorphous carbon electrodes
    Liu, Aiping
    Dong, Wenjun
    Liu, Erjia
    Tang, Weihua
    Zhu, Jiaqi
    Han, Jiecai
    [J]. ELECTROCHIMICA ACTA, 2010, 55 (06) : 1971 - 1977
  • [30] Non-Enzymatic Electrochemical Hydrogen Peroxide Sensor Based on Copper Oxide Hollow Microspheres
    Shuai, Ying
    Liu, Chuanghua
    Wang, Jia
    Ma, Jun
    Cui, Xiaoyan
    [J]. SENSOR LETTERS, 2013, 11 (10) : 1945 - 1949