Non-enzymatic detection of hydrogen peroxide based on Fenton-type reaction on poly(azure A)-chitosan/Cu modified electrode

被引:18
|
作者
Liu, Tong [1 ]
Luo, Yiqun [1 ]
Wang, Wen [1 ]
Kong, Liyan [1 ]
Zhu, Jiaming [1 ]
Tan, Liang [1 ]
机构
[1] Hunan Normal Univ, Coll Chem & Chem Engn, Minist Educ China, Key Lab Chem Biol & Tradit Chinese Med Res, Changsha 410081, Hunan, Peoples R China
关键词
Composite film modified electrode; Fenton-type reaction; Electrocatalysis; Hydrogen peroxide; Non-enzymatic sensor; KINETIC-SPECTROPHOTOMETRIC DETERMINATION; ENHANCED ELECTROCATALYTIC REDUCTION; CARBON NANOTUBES; TRACE AMOUNTS; PYROGALLOL RED; OXIDATION; NANOPARTICLES; COPPER(II); CHITOSAN; SENSOR;
D O I
10.1016/j.electacta.2015.09.063
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work, a sensitive electrochemical method for the detection of H2O2 was proposed based on Fenton-type reaction on the electrode surface. A glassy carbon electrode modified with poly(azure A) (PAA), chitosan (CS) and copper ions, displaying a good electrochemical activity, was fabricated by cyclic voltammetry and the adsorption of Cu2+. Scanning electron microscopy-Energy dispersive spectroscopy analysis, infrared and Raman spectral characterization and XPS measurement showed the stable complexation of Cu2+ with the PAA-CS film. Hydroxyl radicals derived from the Fenton-type reaction between Cu2+ and H2O2 could effectively oxidize poly(azure A), leading to the great reduction-current change of the dye polymer in the electrode process. Under the optimized conditions, the fabricated electrode displayed a linear response in the H2O2 concentration range from 0.002 to 0.5 mM and that from 2.56 to 25.0 mM with a detection limit of 0.7 mM estimated at a signal-to-noise ratio of 3. The good analytical performance including low detection limit, fast response time, low cost, good anti-interference performance, satisfying stability, acceptable repeatability and reliable reproducibility were found from the proposed amperometric sensor, suggesting that the current work could provide a feasible approach for the non-enzymatic H2O2 detection. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:742 / 750
页数:9
相关论文
共 50 条
  • [21] A novel non-enzymatic hydrogen peroxide sensor based on poly-melamine film modified with platinum nanoparticles
    He, Sijing
    Chen, Zuanguang
    Yu, Yanyan
    Shi, Lijuan
    [J]. RSC ADVANCES, 2014, 4 (85): : 45185 - 45190
  • [22] Non-enzymatic electrochemical sensor based on Cu2O/AuCu/Cu composite for hydrogen peroxide detection
    Liang, Xiaoyu
    Li, Weixiang
    Han, Hongliang
    Ma, Zhanfang
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 834 : 43 - 48
  • [23] Radical generation by the non-enzymatic reaction of methylglyoxal and hydrogen peroxide
    Nakayama, Masaaki
    Saito, Keita
    Sato, Emiko
    Nakayama, Keisuke
    Terawaki, Hiroyuki
    Ito, Sadayoshi
    Kohno, Masahiro
    [J]. REDOX REPORT, 2007, 12 (03) : 125 - 133
  • [24] A Non-enzymatic Hydrogen Peroxide Photoelectrochemical Sensor Based on a BiVO4 Electrode
    Liu, Min
    Yu, Yu-Xiang
    Zhang, Wei-De
    [J]. ELECTROANALYSIS, 2017, 29 (01) : 305 - 311
  • [25] Non-Enzymatic Glucose Sensor Based on Cu Electrode Modified with CuO Nanoflowers
    Song, Min-Jung
    Lee, Seung-Koo
    Kim, Jong-Hoon
    Lim, Dae-Soon
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (04) : B43 - B46
  • [26] A nanocomposite-based electrochemical sensor for non-enzymatic detection of hydrogen peroxide
    Du, Xin
    Chen, Yuan
    Dong, Wenhao
    Han, Bingkai
    Liu, Min
    Chen, Qiang
    Zhou, Jun
    [J]. ONCOTARGET, 2017, 8 (08) : 13039 - 13047
  • [27] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a composite consisting of chitosan‐encapsulated graphite and platinum nanoparticles
    Tse-Wei Chen
    Selvakumar Palanisamy
    Shen-Ming Chen
    [J]. Microchimica Acta, 2016, 183 : 2861 - 2869
  • [28] Non-enzymatic detection of hydrogen peroxide using a functionalized three-dimensional graphene electrode
    Xi, Fengna
    Zhao, Dongjiao
    Wang, Xuewan
    Chen, Peng
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2013, 26 : 81 - 84
  • [29] Non-enzymatic polyamic acid sensors for hydrogen peroxide detection
    Zamfir, Lucian-Gabriel
    Rotariu, Lucian
    Marinescu, Virgil Emanuel
    Simelane, Xolani T.
    Baker, Priscilla G. L.
    Iwuoha, Emmanuel I.
    Bala, Camelia
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 226 : 525 - 533
  • [30] Non-enzymatic hydrogen peroxide sensor based on MnO2-ordered mesoporous carbon composite modified electrode
    Luo, Liqiang
    Li, Fang
    Zhu, Limei
    Zhang, Zhao
    Ding, Yaping
    Deng, Dongmei
    [J]. ELECTROCHIMICA ACTA, 2012, 77 : 179 - 183