Non-enzymatic detection of hydrogen peroxide based on Fenton-type reaction on poly(azure A)-chitosan/Cu modified electrode

被引:18
|
作者
Liu, Tong [1 ]
Luo, Yiqun [1 ]
Wang, Wen [1 ]
Kong, Liyan [1 ]
Zhu, Jiaming [1 ]
Tan, Liang [1 ]
机构
[1] Hunan Normal Univ, Coll Chem & Chem Engn, Minist Educ China, Key Lab Chem Biol & Tradit Chinese Med Res, Changsha 410081, Hunan, Peoples R China
关键词
Composite film modified electrode; Fenton-type reaction; Electrocatalysis; Hydrogen peroxide; Non-enzymatic sensor; KINETIC-SPECTROPHOTOMETRIC DETERMINATION; ENHANCED ELECTROCATALYTIC REDUCTION; CARBON NANOTUBES; TRACE AMOUNTS; PYROGALLOL RED; OXIDATION; NANOPARTICLES; COPPER(II); CHITOSAN; SENSOR;
D O I
10.1016/j.electacta.2015.09.063
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work, a sensitive electrochemical method for the detection of H2O2 was proposed based on Fenton-type reaction on the electrode surface. A glassy carbon electrode modified with poly(azure A) (PAA), chitosan (CS) and copper ions, displaying a good electrochemical activity, was fabricated by cyclic voltammetry and the adsorption of Cu2+. Scanning electron microscopy-Energy dispersive spectroscopy analysis, infrared and Raman spectral characterization and XPS measurement showed the stable complexation of Cu2+ with the PAA-CS film. Hydroxyl radicals derived from the Fenton-type reaction between Cu2+ and H2O2 could effectively oxidize poly(azure A), leading to the great reduction-current change of the dye polymer in the electrode process. Under the optimized conditions, the fabricated electrode displayed a linear response in the H2O2 concentration range from 0.002 to 0.5 mM and that from 2.56 to 25.0 mM with a detection limit of 0.7 mM estimated at a signal-to-noise ratio of 3. The good analytical performance including low detection limit, fast response time, low cost, good anti-interference performance, satisfying stability, acceptable repeatability and reliable reproducibility were found from the proposed amperometric sensor, suggesting that the current work could provide a feasible approach for the non-enzymatic H2O2 detection. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:742 / 750
页数:9
相关论文
共 50 条
  • [41] Copper oxide nanoparticles and ionic liquid modified carbon electrode for the non-enzymatic electrochemical sensing of hydrogen peroxide
    Jianfeng Ping
    Shiping Ru
    Kai Fan
    Jian Wu
    Yibin Ying
    [J]. Microchimica Acta, 2010, 171 : 117 - 123
  • [42] A glassy carbon electrode modified with a nanocomposite consisting of carbon nanohorns and poly(2-aminopyridine) for non-enzymatic amperometric determination of hydrogen peroxide
    Chen, Jingchao
    He, Ping
    Bai, Hongmei
    Lei, Hong
    Zhang, Guangli
    Dong, Faqin
    Ma, Yongjun
    [J]. MICROCHIMICA ACTA, 2016, 183 (12) : 3237 - 3242
  • [43] A glassy carbon electrode modified with a nanocomposite consisting of carbon nanohorns and poly(2-aminopyridine) for non-enzymatic amperometric determination of hydrogen peroxide
    Jingchao Chen
    Ping He
    Hongmei Bai
    Hong Lei
    Guangli Zhang
    Faqin Dong
    Yongjun Ma
    [J]. Microchimica Acta, 2016, 183 : 3237 - 3242
  • [44] Synthesis of a CuNP/chitosan/black phosphorus nanocomposite for non-enzymatic hydrogen peroxide sensing
    Zhao, Yun
    Zhuge, Zhen
    Tang, Yi-Hong
    Tao, Jian-Wei
    [J]. ANALYST, 2020, 145 (22) : 7260 - 7266
  • [45] Copper Oxide Chitosan Nanocomposite: Characterization and Application in Non-Enzymatic Hydrogen Peroxide Sensing
    Arena, Antonella
    Scandurra, Graziella
    Ciofi, Carmine
    [J]. SENSORS, 2017, 17 (10)
  • [46] A Non-enzymatic Hydrogen Peroxide Sensor Based on CuO Nanoparticles/polyaniline on Flexible CNT Fiber Electrode
    Song, Min-Jung
    [J]. KOREAN CHEMICAL ENGINEERING RESEARCH, 2023, 61 (02): : 196 - 201
  • [47] Functionalized graphene oxide–polypyrrole–chitosan (fGO–PPy–CS) modified screen-printed electrodes for non-enzymatic hydrogen peroxide detection
    Muhammad Asim Akhtar
    Akhtar Hayat
    Naseer Iqbal
    Jean Louis Marty
    Mian Hasnain Nawaz
    [J]. Journal of Nanoparticle Research, 2017, 19
  • [48] A novel non-enzymatic glucose sensor based on Cu nanoparticle modified graphene sheets electrode
    Luo, Jing
    Jiang, Sisi
    Zhang, Hongyan
    Jiang, Jinqiang
    Liu, Xiaoya
    [J]. ANALYTICA CHIMICA ACTA, 2012, 709 : 47 - 53
  • [49] An improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrode
    Zhuang, Zhenjing
    Su, Xiaodong
    Yuan, Hongyan
    Sun, Qun
    Xiao, Dan
    Choi, Martin M. F.
    [J]. ANALYST, 2008, 133 (01) : 126 - 132
  • [50] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    [J]. MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395