A new modified electrode based on Ag-doped mesoporous SBA-16 nanoparticles as non-enzymatic sensor for hydrogen peroxide

被引:43
|
作者
Azizi, Seyed Naser [1 ]
Ghasemi, Shahram [2 ]
Samadi-Maybodi, Abdolraoof [1 ]
Ranjbar-Azad, Mohammad [1 ]
机构
[1] Univ Mazandaran, Fac Chem, Analyt Div, Babol Sar 4741695447, Iran
[2] Univ Mazandaran, Fac Chem, Babol Sar 4741695447, Iran
来源
关键词
Stem cane ash; Mesoporous silica nanoparticles; Ag-doped SBA-16; H2O2; Electrocatalytic reduction; GLASSY-CARBON ELECTRODE; ELECTROCHEMICAL-BEHAVIOR; PASTE ELECTRODE; SOLVENT-FREE; H2O2; SILICA; NANOTUBES; REDUCTION; LIQUID; PD;
D O I
10.1016/j.snb.2015.03.078
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new electrode based on carbon paste (CP) modified with Ag-doped SBA-16 mesoporous silica was used to determine H2O2 concentration in phosphate buffer solution (PBS). Mesoporous silica SBA-16 nanoparticles were synthesized hydrothermally under the acidic medium using SiO2/F127/BuOH/HCl/H2O gel. Pure SiO2 powder is prepared from inexpensive and environmentally friendly silica source of stem cane ash (SCA). The physico-chemical characteristics of the mesoporous silica SBA-16 such as surface area, pore size distribution, pore volume, chemical composition and crystallite size were studied using various techniques such as X-ray diffraction (XRD), scanning electronic microscopy (SEM), transmission electron microscopy (TEM), Brumauer-Emmett-Teller (BET) and FT-IR techniques. The sizes of mesoporous silica SBA-16 nanoparticles are in the range of 30-60 nm. The modified electrode was used to investigate the electrocatalytic reduction of H2O2 by cyclic voltammetry and amperometry. Cyclic voltammetry method indicates that the current intensity of H2O2 reduction on the surface of modified electrode is higher than that on nonmodified CPE. This sensor could detect H2O2 in two linear ranges of 20 mu M to 8 mM and 8 to 20 mM with a detection limit of 2.95 mu M at a signal-to-noise ratio of 3 and a response time of 2 s. Furthermore, this sensor exhibits good anti-interference property and selectivity. The Ag/SBA-16/CPE has good reproducibility and long term stability, and it was successfully applied for the determination of H2O2 in pharmaceutical sample: a hair dying cream. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [1] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Yin, Guang
    Xing, Ling
    Ma, Xiu-Ju
    Wan, Jun
    [J]. CHEMICAL PAPERS, 2014, 68 (04): : 435 - 441
  • [2] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Guang Yin
    Ling Xing
    Xiu-Ju Ma
    Jun Wan
    [J]. Chemical Papers, 2014, 68 : 435 - 441
  • [3] Non-enzymatic hydrogen peroxide sensor using an electrode modified with iron pentacyanonitrosylferrate nanoparticles
    Habib Razmi
    Rahim Mohammad-Rezaei
    [J]. Microchimica Acta, 2010, 171 : 257 - 265
  • [4] Non-enzymatic hydrogen peroxide sensor using an electrode modified with iron pentacyanonitrosylferrate nanoparticles
    Razmi, Habib
    Mohammad-Rezaei, Rahim
    [J]. MICROCHIMICA ACTA, 2010, 171 (3-4) : 257 - 265
  • [5] Non-enzymatic sensor based on a glassy carbon electrode modified with Ag nanoparticles/polyaniline/halloysite nanotube nanocomposites for hydrogen peroxide sensing
    Yang, Ziyin
    Zheng, Xiaohui
    Zheng, Jianbin
    [J]. RSC ADVANCES, 2016, 6 (63) : 58329 - 58335
  • [6] Non-enzymatic hydrogen peroxide sensor based on MnO2-ordered mesoporous carbon composite modified electrode
    Luo, Liqiang
    Li, Fang
    Zhu, Limei
    Zhang, Zhao
    Ding, Yaping
    Deng, Dongmei
    [J]. ELECTROCHIMICA ACTA, 2012, 77 : 179 - 183
  • [7] A Non-Enzymatic Hydrogen Peroxide Sensor Based on Ag/MnOOH Nanocomposites
    Bai, Wushuang
    Zheng, Jianbin
    Sheng, Qinglin
    [J]. ELECTROANALYSIS, 2013, 25 (10) : 2305 - 2311
  • [8] A non-enzymatic sensor for hydrogen peroxide based on polyaniline, multiwalled carbon nanotubes and gold nanoparticles modified Au electrode
    Narang, Jagriti
    Chauhan, Nidhi
    Pundir, C. S.
    [J]. ANALYST, 2011, 136 (21) : 4460 - 4466
  • [9] A simple non-enzymatic hydrogen peroxide sensor using gold nanoparticles-graphene-chitosan modified electrode
    Jia, Ningming
    Huang, Baozhen
    Chen, Lina
    Tan, Liang
    Yao, Shouzhuo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 195 : 165 - 170
  • [10] A Non-enzymatic Hydrogen Peroxide Sensor Based on CuO Nanoparticles/polyaniline on Flexible CNT Fiber Electrode
    Song, Min-Jung
    [J]. KOREAN CHEMICAL ENGINEERING RESEARCH, 2023, 61 (02): : 196 - 201