Early clinical results of St. Jude Medical Symmetry aortic connector

被引:3
|
作者
Toyama M. [1 ]
Usui A. [1 ]
Abe T. [1 ]
Yoshikawa M. [1 ]
Akita T. [1 ]
Ueda Y. [1 ]
机构
[1] Department of Cardiothoracic Surgery, Nagoya University, Graduate School of Medicine, Showa-ku, Nagoya 466-8550
关键词
Aortic connector; Graft flow; Hyperlipidemia; Patency; Saphenous vein graft;
D O I
10.1007/s10047-005-0293-0
中图分类号
学科分类号
摘要
An automated anastomosis device named St. Jude Medical symmetry aortic connector has been used worldwide for off-pump coronary artery bypass grafting. However, early graft obstruction was recently reported, and its predictors should be clarified. From April 2002 to March 2004, 38 patients in our institution underwent off-pump coronary artery bypass grafting using the St. Jude Medical Symmetry aortic connector for saphenous vein graft (SVG) procedures; measurement of intraoperative graft flow and postoperative coronary angiography was performed. Early SVG events occurred in 9 (24%) patients: 8 occlusion cases and 1 case of stenosis. Predictors of early SVG events were assessed from a comparative study. Univariate logistic regression identified hyperlipidemia as the only significant predictor of early SVG events (P = 0.02, odds ratio 7.78). Lower SVG flow rate and poor ejection fraction did not show statistical significance (P = 0.09, odds ratio 1.09 and P = 0.09, odds ratio 0.96). The SVG event rate was much higher for the left circumflex branch compared with other locations (31% vs. 9%, P = 0.03) and decreased with increasing aortic connector size (small, 32%; median, 14%; large, 0%). Multivariate analysis did not identify a predictor of SVG events. The aortic connector is associated with a high incidence of early SVG events. Patients should be cautiously selected and the procedure should not be used for left anterior descending coronary artery or culprit lesions. © The Japanese Society for Artificial Organs 2005.
引用
收藏
页码:95 / 99
页数:4
相关论文
共 50 条
  • [41] Performance of the St. Jude Medical Riata Leads
    Epstein, Andrew E.
    Baker, James H.
    Beau, Scott L.
    Deering, Thomas F.
    Greenberg, Steven M.
    Goldman, Daniel S.
    HEART RHYTHM, 2009, 6 (02) : 204 - 209
  • [42] St. Jude Medical Portico™ transapical technology
    Cheung, Anson
    Makkar, Raj
    Fontana, Gregory P.
    EUROINTERVENTION, 2013, 9 : S103 - S106
  • [43] Twenty-year experience with the St. Jude Medical Biocor bioprosthesis in the aortic position
    Eichinger, W.
    AORTIC ROOT SURGERY: THE BIOLOGICAL SOLUTION, 2010, : 452 - 462
  • [44] Twenty-year experience with the St. Jude Medical Biocor bioprosthesis in the aortic position
    Eichinger, Walter B.
    Hettich, Ina M.
    Ruzicka, Daniel J.
    Holper, Klaus
    Schricker, Carolin
    Bleiziffer, Sabine
    Lange, Ruediger
    ANNALS OF THORACIC SURGERY, 2008, 86 (04): : 1204 - 1211
  • [45] St. Jude Medical prosthetic aortic valve malfunction due to pannus formation.
    Naito Y.
    Hachida M.
    Shimabukuro T.
    Nonoyama M.
    Endo M.
    Koyanagi H.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2000, 48 (11): : 739 - 741
  • [46] St. jude medical trifecta ™ aortic bioprosthesis-an assessment of midterm haemodynamic function
    McCormack, D. J.
    Sepehripour, A. H.
    Lall, K. S.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 13 - 13
  • [47] Hemolysis parameters of St. Jude Medical hemodynamic Plus® and Regent® valves in aortic position
    Suedkamp, M
    Lercher, AJ
    Riemenschneider, FM
    LaRosee, K
    Tossios, P
    Mehlhorn, U
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2004, 95 (01) : 89 - 93
  • [48] Single Center Midterm Results from the FDA Trial of the St. Jude Medical Trifecta™ Pericardial Aortic Valve Bioprosthesis
    Bavaria, J. E.
    Szeto, W.
    Covington, C.
    Burtch, K.
    Blaskovich, V.
    Komlo, C.
    Desai, N.
    CARDIOLOGY, 2012, 121 (02) : 92 - 93
  • [49] Comparison of dobutamine-induced haemodynamic changes in 21 mm St. Jude medical prosthesis without aortic root enlargement and 23 mm St. Jude with aortic root enlargement
    Yetkin, E
    Kandemir, O
    Yscan, HZ
    Nisanoglu, V
    Fansa, I
    Tasdemir, O
    EUROPEAN HEART JOURNAL, 2001, 22 : 312 - 312
  • [50] An experimental model of saphenous vein-to-coronary artery anastomosis with the St. Jude medical stainless steel connector
    Schaff, HV
    Zehr, KJ
    Bonilla, LF
    Brennecke, LH
    Berg, T
    Cornelius, R
    Hindrichs, P
    Swanson, W
    ANNALS OF THORACIC SURGERY, 2002, 73 (03): : 830 - 835