Hemolysis parameters of St. Jude Medical hemodynamic Plus® and Regent® valves in aortic position

被引:5
|
作者
Suedkamp, M
Lercher, AJ
Riemenschneider, FM
LaRosee, K
Tossios, P
Mehlhorn, U
机构
[1] Univ Cologne, Dept Cardiothorac Surg, D-50924 Cologne, Germany
[2] Univ Cologne, Dept Cardiol, D-50924 Cologne, Germany
关键词
hemolysis; prosthetic heart valves; plasma lactate dehydrogenase; St. Jude Medical Regent (R) prosthesis;
D O I
10.1016/j.ijcard.2003.05.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Elevated plasma lactate dehydrogenase (LDH) concentration may reflect hemolysis due to mechanical heart valve dysfunction. Thus, knowledge of LDH levels in patients with properly working prostheses is required. Because hemolysis parameters for the SJM Hemodynamic Plus((R)) (HP(R)) and Regent((R)) series are currently not available, the purpose of our study was to determine these data. Methods: At 12-19 months follow-up after isolated aortic valve replacement with SJM HP(R) or Regent 101 prostheses, we examined 102 patients by transthoracic echocardiography and determined plasma LDH, haptoglobin, bilirubin and hemoglobin. Results: Five patients with properly working prostheses were excluded because of increased LDH due to non-cardiac reasons. In four patients with paravalvular leakage, LDH was 244, 307, 446 and 628 U/l, respectively. In patients with properly working prostheses, LDH was 287 +/- 52 (range: 163-374) U/l for HP(R) (n = 33) and 274 +/- 48 (151-386) U/l for Regent((R)) valves (n = 60, p = 0.2). Haptoglobin was < 1 g/l in all patients; in 91% of HP and 75% of Regent((R)) valves, haptoglobin was below detection limit. Bilirubin and hemoglobin as well as red blood cell count (RBC) were normal in all patients except for five patients with renal anemia, two patients with paravalvular leakage and four patients with macrocytosis due to alcohol abuse. There was no correlation between LDH and transvalvular gradient (r = -0.02) or valve size (r = 0.25). Conclusions: In patients with SJM HP(R) or Regent((R)) valves in aortic position, LDH values > 400 U/l indicate valvular dysfunction or leakage if non-cardiac causes for hemolysis are excluded. However, paravalvular leakage can be present without substantially increased LDH. Haptoglobin has no diagnostic value as it is almost always markedly reduced. Hemolysis does not correlate with transvalvular gradient or prosthesis size. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:89 / 93
页数:5
相关论文
共 50 条
  • [1] Preliminary experience with the St. Jude Medical Regent mechanical heart valve in the aortic position: Early in vivo hemodynamic results
    Gelsomino, S
    Morocutti, G
    Da Col, P
    Frassani, R
    Carella, R
    Minen, G
    Livi, U
    ANNALS OF THORACIC SURGERY, 2002, 73 (06): : 1830 - 1836
  • [2] Hemodynamic performance of the St. Jude Medical Hemodynamic Plus valve
    Second Department of Surgery, Kurume University Hospital, Kurume, Japan
    不详
    ARTIF. ORGANS, 8 (916-921):
  • [3] Obstruction of St Jude Medical valves in the aortic position
    Baciewicz, FA
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (06): : 1851 - 1851
  • [4] Preliminary experience with the St. Jude Medical Regent mechanical heart valve in the aortic position: Early in vivo hemodynamic results - Invited commentary
    Jamieson, WRE
    ANNALS OF THORACIC SURGERY, 2002, 73 (06): : 1836 - 1836
  • [5] Standard versus hemodynamic plus 19-MM St Jude Medical aortic valves
    Ismeno, G
    Renzulli, A
    De Feo, M
    Della Corte, A
    Covino, FE
    Cotrufo, M
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (04): : 723 - 728
  • [6] Hemodynamics and early performance of the St. Jude Medical Regent™ aortic valve prosthesis
    Bach, DS
    Goldbach, M
    Sakwa, MP
    Petracek, M
    Errett, L
    Mohr, F
    JOURNAL OF HEART VALVE DISEASE, 2001, 10 (04): : 436 - 442
  • [7] Hemodynamics and early clinical performance of the St. Jude Medical Regent mechanical aortic valve
    Bach, DS
    Sakwa, MP
    Goldbach, M
    Petracek, MR
    Emery, RW
    Mohr, FW
    ANNALS OF THORACIC SURGERY, 2002, 74 (06): : 2003 - 2009
  • [8] Reference Doppler echocardiographic values for St. Jude Medical, Omnicarbon, and Biocor prosthetic valves in the aortic position
    Bech-Hanssen, O
    Wallentin, I
    Larsson, S
    Caidahl, K
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (05) : 466 - 477
  • [9] Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography
    Minardi, Giovanni
    Manzara, Carla
    Creazzo, Vittorio
    Maselli, Daniele
    Casali, Giovanni
    Pulignano, Giovanni
    Musumeci, Francesco
    JOURNAL OF CARDIOTHORACIC SURGERY, 2006, 1 (1)
  • [10] Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography
    Giovanni Minardi
    Carla Manzara
    Vittorio Creazzo
    Daniele Maselli
    Giovanni Casali
    Giovanni Pulignano
    Francesco Musumeci
    Journal of Cardiothoracic Surgery, 1