Hemolysis parameters of St. Jude Medical hemodynamic Plus® and Regent® valves in aortic position

被引:5
|
作者
Suedkamp, M
Lercher, AJ
Riemenschneider, FM
LaRosee, K
Tossios, P
Mehlhorn, U
机构
[1] Univ Cologne, Dept Cardiothorac Surg, D-50924 Cologne, Germany
[2] Univ Cologne, Dept Cardiol, D-50924 Cologne, Germany
关键词
hemolysis; prosthetic heart valves; plasma lactate dehydrogenase; St. Jude Medical Regent (R) prosthesis;
D O I
10.1016/j.ijcard.2003.05.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Elevated plasma lactate dehydrogenase (LDH) concentration may reflect hemolysis due to mechanical heart valve dysfunction. Thus, knowledge of LDH levels in patients with properly working prostheses is required. Because hemolysis parameters for the SJM Hemodynamic Plus((R)) (HP(R)) and Regent((R)) series are currently not available, the purpose of our study was to determine these data. Methods: At 12-19 months follow-up after isolated aortic valve replacement with SJM HP(R) or Regent 101 prostheses, we examined 102 patients by transthoracic echocardiography and determined plasma LDH, haptoglobin, bilirubin and hemoglobin. Results: Five patients with properly working prostheses were excluded because of increased LDH due to non-cardiac reasons. In four patients with paravalvular leakage, LDH was 244, 307, 446 and 628 U/l, respectively. In patients with properly working prostheses, LDH was 287 +/- 52 (range: 163-374) U/l for HP(R) (n = 33) and 274 +/- 48 (151-386) U/l for Regent((R)) valves (n = 60, p = 0.2). Haptoglobin was < 1 g/l in all patients; in 91% of HP and 75% of Regent((R)) valves, haptoglobin was below detection limit. Bilirubin and hemoglobin as well as red blood cell count (RBC) were normal in all patients except for five patients with renal anemia, two patients with paravalvular leakage and four patients with macrocytosis due to alcohol abuse. There was no correlation between LDH and transvalvular gradient (r = -0.02) or valve size (r = 0.25). Conclusions: In patients with SJM HP(R) or Regent((R)) valves in aortic position, LDH values > 400 U/l indicate valvular dysfunction or leakage if non-cardiac causes for hemolysis are excluded. However, paravalvular leakage can be present without substantially increased LDH. Haptoglobin has no diagnostic value as it is almost always markedly reduced. Hemolysis does not correlate with transvalvular gradient or prosthesis size. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:89 / 93
页数:5
相关论文
共 50 条
  • [21] Hemodynamic performance of the St Jude Medical Hemodynamic Plus Valve
    Hayashida, N
    Isomura, T
    Hisatomi, K
    Sato, T
    Maruyama, H
    Kosuga, K
    Aoyagi, S
    ARTIFICIAL ORGANS, 1997, 21 (08) : 916 - 921
  • [22] Acute leaflet arrest in St Jude Medical Regent aortic valve
    Ovrum, E
    Tangen, G
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 129 (06): : 1446 - 1446
  • [23] Obstruction of St Jude Medical valves in the aortic position: Significance of a combination of cineradiography and echocardiography
    Aoyagi, S
    Nishimi, M
    Kawano, H
    Tayama, E
    Fukunaga, S
    Hayashida, N
    Akashi, H
    Kawara, T
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 120 (01): : 142 - 147
  • [24] St Jude Medical Regent valve
    Emery, RW
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (03): : 760 - 761
  • [25] COMPREHENSIVE HEMODYNAMIC COMPARISON AND FREQUENCY OF PATIENT PROSTHESIS MISMATCH BETWEEN THE ST. JUDE MEDICAL EPIC AND TRIFECTA BIOPROSTHETIC AORTIC VALVES
    Yadlapati, Ajay
    Barnes, Mary Jo
    Diep, Jimmy
    Bethencourt, Daniel
    Vorobiof, Gabriel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1986 - E1986
  • [26] Mitral and mitro-aortic valve replacement with Sorin Bicarbon valves compared with St. Jude Medical valves
    Camilleri, LF
    Bailly, P
    Legault, BJ
    Miguel, B
    D'Agrosa-Boiteux, MD
    de Riberolles, CM
    CARDIOVASCULAR SURGERY, 2001, 9 (03): : 272 - 280
  • [27] Mid-term results of small-sized St. Jude Medical Regent prosthetic valves (21 mm or less) for small aortic annulus
    Hiroki Mizoguchi
    Masayuki Sakaki
    Kazushige Inoue
    Takashi Iwata
    Keikou Tei
    Takuya Miura
    Heart and Vessels, 2013, 28 : 769 - 774
  • [28] Mid-term results of small-sized St. Jude Medical Regent prosthetic valves (21 mm or less) for small aortic annulus
    Mizoguchi, Hiroki
    Sakaki, Masayuki
    Inoue, Kazushige
    Iwata, Takashi
    Tei, Keikou
    Miura, Takuya
    HEART AND VESSELS, 2013, 28 (06) : 769 - 774
  • [29] The 17-mm St. Jude Medical Regent Valve Is a Valid Option for Patients With a Small Aortic Annulus
    Okamura, Homare
    Yamaguchi, Atsushi
    Tanaka, Masashi
    Naito, Kazuhiro
    Kimura, Naoyuki
    Kimura, Chieri
    Kobinata, Toshiyuki
    Ino, Takashi
    Adachi, Hideo
    ANNALS OF THORACIC SURGERY, 2009, 87 (01): : 90 - 94
  • [30] Twenty-year experience with the St. Jude Medical Biocor bioprosthesis in the aortic position
    Eichinger, W.
    AORTIC ROOT SURGERY: THE BIOLOGICAL SOLUTION, 2010, : 452 - 462