Hemolysis parameters of St. Jude Medical hemodynamic Plus® and Regent® valves in aortic position

被引:5
|
作者
Suedkamp, M
Lercher, AJ
Riemenschneider, FM
LaRosee, K
Tossios, P
Mehlhorn, U
机构
[1] Univ Cologne, Dept Cardiothorac Surg, D-50924 Cologne, Germany
[2] Univ Cologne, Dept Cardiol, D-50924 Cologne, Germany
关键词
hemolysis; prosthetic heart valves; plasma lactate dehydrogenase; St. Jude Medical Regent (R) prosthesis;
D O I
10.1016/j.ijcard.2003.05.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Elevated plasma lactate dehydrogenase (LDH) concentration may reflect hemolysis due to mechanical heart valve dysfunction. Thus, knowledge of LDH levels in patients with properly working prostheses is required. Because hemolysis parameters for the SJM Hemodynamic Plus((R)) (HP(R)) and Regent((R)) series are currently not available, the purpose of our study was to determine these data. Methods: At 12-19 months follow-up after isolated aortic valve replacement with SJM HP(R) or Regent 101 prostheses, we examined 102 patients by transthoracic echocardiography and determined plasma LDH, haptoglobin, bilirubin and hemoglobin. Results: Five patients with properly working prostheses were excluded because of increased LDH due to non-cardiac reasons. In four patients with paravalvular leakage, LDH was 244, 307, 446 and 628 U/l, respectively. In patients with properly working prostheses, LDH was 287 +/- 52 (range: 163-374) U/l for HP(R) (n = 33) and 274 +/- 48 (151-386) U/l for Regent((R)) valves (n = 60, p = 0.2). Haptoglobin was < 1 g/l in all patients; in 91% of HP and 75% of Regent((R)) valves, haptoglobin was below detection limit. Bilirubin and hemoglobin as well as red blood cell count (RBC) were normal in all patients except for five patients with renal anemia, two patients with paravalvular leakage and four patients with macrocytosis due to alcohol abuse. There was no correlation between LDH and transvalvular gradient (r = -0.02) or valve size (r = 0.25). Conclusions: In patients with SJM HP(R) or Regent((R)) valves in aortic position, LDH values > 400 U/l indicate valvular dysfunction or leakage if non-cardiac causes for hemolysis are excluded. However, paravalvular leakage can be present without substantially increased LDH. Haptoglobin has no diagnostic value as it is almost always markedly reduced. Hemolysis does not correlate with transvalvular gradient or prosthesis size. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:89 / 93
页数:5
相关论文
共 50 条
  • [41] Mid-term results of 17-mm St. Jude Medical Regent prosthetic valves in elder patients with small aortic annuli: comparison with 19-mm bioprosthetic valves
    Teshima, Hideki
    Ikebuchi, Masahiko
    Sano, Toshikazu
    Tai, Ryuta
    Horio, Naohiro
    Irie, Hiroyuki
    JOURNAL OF ARTIFICIAL ORGANS, 2014, 17 (03) : 258 - 264
  • [42] Comprehensive Hemodynamic Evaluation and Early Performance of the St. Jude Medical Trifecta™ Aortic Valve Tissue Prosthesis
    Vorobiof, G.
    Diep, J.
    Barnes, M. J.
    Bethencourt, D. M.
    CARDIOLOGY, 2012, 121 (02) : 143 - 144
  • [43] Effect of heart rate on the hemodynamics of bileaflet mechanical heart valves' prostheses (St. Jude Medical) in the aortic position and in the opening phase: A computational study
    Jahandardoost, Mehdi
    Fradet, Guy
    Mohammadi, Hadi
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (03) : 175 - 190
  • [44] St. Jude medical trifecta ™ aortic bioprosthesis - the training perspective
    Sepehripour, A. H.
    McCormack, D. J.
    Lall, K. S.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 165 - 165
  • [45] Hemodynamic study of the elliptic St. Jude Medical valve: A computational study
    Jahandardoost, Mehdi
    Fradet, Guy
    Mohammadi, Hadi
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (02) : 85 - 96
  • [46] Mid-Term Outcomes After Aortic Valve Replacement With the 17-mm St. Jude Medical Regent Valve
    Okamura, Homare
    Yamaguchi, Atsushi
    Nagano, Hiroshi
    Itoh, Satoshi
    Morita, Hideki
    Naito, Kazuhiro
    Yuri, Koichi
    Adachi, Hideo
    CIRCULATION JOURNAL, 2012, 76 (02) : 365 - 371
  • [47] Doppler echocardiographic evaluation of St. Jude Medical valves in the tricuspid position - Criteria for normal and abnormal valve function
    Sezai, A
    Shiono, M
    Akiyama, K
    Orime, Y
    Hata, H
    Yagi, S
    Tsukamoto, S
    Nakata, K
    Hata, M
    Negishi, N
    Sezai, Y
    JOURNAL OF CARDIOVASCULAR SURGERY, 2001, 42 (03): : 303 - 309
  • [48] Left ventricular mass regression after implantation of St. Jude Medical cardiac valves in small aortic roots
    Dept. Thorac. and Cardiovasc. Surg., Kawasaki Medical School, Kurashiki, Japan
    不详
    Artif. Organs, 9 (740-745):
  • [49] The new St. Jude Medical Regent™ mechanical heart valve:: Laboratory measurements of hydrodynamic performance
    Walker, DK
    Brendzel, AM
    Scotten, LN
    JOURNAL OF HEART VALVE DISEASE, 1999, 8 (06): : 687 - 696
  • [50] Laser texturing of a St. Jude Medical Regent™ mechanical heart valve prosthesis: the proof of concept
    Vigano, Giorgio
    ten Brink, Gert H.
    Groenendijk, Max
    Sipkema, Ronald
    Pollack, Daniel K. M.
    Mariani, Massimo A.
    Kooi, Bart J.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2021, 33 (06) : 986 - 991