Early clinical results of St. Jude Medical Symmetry aortic connector

被引:3
|
作者
Toyama M. [1 ]
Usui A. [1 ]
Abe T. [1 ]
Yoshikawa M. [1 ]
Akita T. [1 ]
Ueda Y. [1 ]
机构
[1] Department of Cardiothoracic Surgery, Nagoya University, Graduate School of Medicine, Showa-ku, Nagoya 466-8550
关键词
Aortic connector; Graft flow; Hyperlipidemia; Patency; Saphenous vein graft;
D O I
10.1007/s10047-005-0293-0
中图分类号
学科分类号
摘要
An automated anastomosis device named St. Jude Medical symmetry aortic connector has been used worldwide for off-pump coronary artery bypass grafting. However, early graft obstruction was recently reported, and its predictors should be clarified. From April 2002 to March 2004, 38 patients in our institution underwent off-pump coronary artery bypass grafting using the St. Jude Medical Symmetry aortic connector for saphenous vein graft (SVG) procedures; measurement of intraoperative graft flow and postoperative coronary angiography was performed. Early SVG events occurred in 9 (24%) patients: 8 occlusion cases and 1 case of stenosis. Predictors of early SVG events were assessed from a comparative study. Univariate logistic regression identified hyperlipidemia as the only significant predictor of early SVG events (P = 0.02, odds ratio 7.78). Lower SVG flow rate and poor ejection fraction did not show statistical significance (P = 0.09, odds ratio 1.09 and P = 0.09, odds ratio 0.96). The SVG event rate was much higher for the left circumflex branch compared with other locations (31% vs. 9%, P = 0.03) and decreased with increasing aortic connector size (small, 32%; median, 14%; large, 0%). Multivariate analysis did not identify a predictor of SVG events. The aortic connector is associated with a high incidence of early SVG events. Patients should be cautiously selected and the procedure should not be used for left anterior descending coronary artery or culprit lesions. © The Japanese Society for Artificial Organs 2005.
引用
收藏
页码:95 / 99
页数:4
相关论文
共 50 条
  • [21] St. Jude Medical Trifecta aortic valve: results from a prospective regional multicentre registry
    Mariscalco, Giovanni
    Mariani, Silvia
    Bichi, Samuele
    Biondi, Andrea
    Blasio, Andrea
    Borsani, Paolo
    Corti, Fabrizio
    De Chiara, Benedetta
    Gherli, Riccardo
    Leva, Cristian
    Russo, Claudio Francesco
    Tasca, Giordano
    Vanelli, Paolo
    Alfieri, Ottavio
    Antona, Carlo
    Di Credico, Germano
    Esposito, Giampiero
    Gamba, Amando
    Martinelli, Luigi
    Menicanti, Lorenzo
    Paolini, Giovanni
    Beghi, Cesare
    JOURNAL OF CARDIOTHORACIC SURGERY, 2015, 10
  • [22] New St Jude Medical Portico™ transcatheter aortic valve: features and early results
    Spence, M. S.
    Lyons, K.
    Mcverry, F.
    Smith, B.
    Manoharan, G. B.
    Maguire, C.
    Doherty, R.
    Anderson, L.
    Morton, A.
    Hughes, S.
    Hoeritzauer, I.
    Manoharan, G.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (03): : 263 - 269
  • [23] Flow dynamics of the St Jude Medical Symmetry aortic connector vein graft anastomosis do not contribute to the risk of acute thrombosis
    Redaelli, A
    Maisano, F
    Ligorio, G
    Cattaneo, E
    Montevecchi, FM
    Alfieri, O
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 128 (01): : 117 - 123
  • [24] CLINICAL AND HEMODYNAMIC-RESULTS WITH THE ST JUDE MEDICAL AORTIC-VALVE PROSTHESIS
    EMERY, RW
    ANDERSON, RW
    LINDSAY, WG
    JORGENSEN, CR
    WANG, Y
    NICOLOFF, DM
    SURGICAL FORUM, 1979, 30 : 235 - 238
  • [25] Thrombogenicity and Reoperation of the St. Jude Medical Silzone® valve:: A comparison with the conventional St. Jude medical valve
    Stalenhoef, JE
    Mellema, EC
    Veeger, NJGM
    Ebels, T
    JOURNAL OF HEART VALVE DISEASE, 2003, 12 (05): : 635 - 639
  • [26] Long-term results with the St. Jude Medical aortic valve: A 25-year experience
    Emery, RW
    Arom, KV
    Krogh, C
    Joyce, LD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 429A - 429A
  • [27] Comprehensive Hemodynamic Evaluation and Early Performance of the St. Jude Medical Trifecta™ Aortic Valve Tissue Prosthesis
    Vorobiof, G.
    Diep, J.
    Barnes, M. J.
    Bethencourt, D. M.
    CARDIOLOGY, 2012, 121 (02) : 143 - 144
  • [28] Preliminary experience with the St. Jude Medical Regent mechanical heart valve in the aortic position: Early in vivo hemodynamic results - Invited commentary
    Jamieson, WRE
    ANNALS OF THORACIC SURGERY, 2002, 73 (06): : 1836 - 1836
  • [29] Mid-term follow up of patients using the St. Jude Medical Aortic Connector System for proximal vein graft in CABG
    Chung, Cheol Hyun
    Lee, Jae Won
    Kang, Joon Kyu
    Song, Hyun
    Choo, Suk Jung
    Song, Meong Gun
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2006, 21 (05) : 849 - 853
  • [30] Hemodynamic Performance of the St. Jude Medical Epic™ Supra Aortic Stented Valve
    Maitland, A.
    Hirsch, G. M.
    Pascoe, E. A.
    CARDIOLOGY, 2010, 115 (04) : 276 - 276