Half-dose abdominal CT with sinogram-affirmed iterative reconstruction technique in children — comparison with full-dose CT with filtered back projection

被引:0
|
作者
Minwook Lee
Myung-Joon Kim
Kyung Hwa Han
Mi-Jung Lee
机构
[1] Yonsei University College of Medicine,Department of Radiology and Research Institute of Radiological Science, Severance Children’s Hospital
[2] Yonsei University College of Medicine,Gangnam Medical Research Center, Biostatistics Collaboration Unit
来源
Pediatric Radiology | 2015年 / 45卷
关键词
Computed tomography; Radiation dose; Image quality; Iterative reconstruction; Children;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:188 / 193
页数:5
相关论文
共 50 条
  • [41] Dose reduction in chest CT: Comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques
    Yamada, Yoshitake
    Jinzaki, Masahiro
    Hosokawa, Takahiro
    Tanami, Yutaka
    Sugiura, Hiroaki
    Abe, Takayuki
    Kuribayashi, Sachio
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) : 4185 - 4195
  • [42] Diagnostic Accuracy of CT Enterography for Active Inflammatory Terminal Ileal Crohn Disease: Comparison of Full-Dose and Half-Dose Images Reconstructed with FBP and Half-Dose Images with SAFIRE
    Gandhi, Namita S.
    Baker, Mark E.
    Goenka, Ajit H.
    Bullen, Jennifer A.
    Obuchowski, Nancy A.
    Remer, Erick M.
    Coppa, Christopher P.
    Einstein, David
    Feldman, Myra K.
    Kanmaniraja, Devaraju
    Purysko, Andrei S.
    Vahdat, Noushin
    Primak, Andrew N.
    Karim, Wadih
    Herts, Brian R.
    RADIOLOGY, 2016, 280 (02) : 436 - 445
  • [43] Comparison study of image quality between filtered back projection and iterative reconstruction algorithm for dose reduction in chest CT
    Son, Junyoung
    Lee, Donghoon
    Jeon, Pil-Hyun
    Choi, Sunghoon
    Kim, Hyemi
    Kim, Hee-Joung
    INTERNATIONAL FORUM ON MEDICAL IMAGING IN ASIA 2019, 2019, 11050
  • [44] Low-Dose Abdominal CT Using a Deep Learning-Based Denoising Algorithm: A Comparison with CT Reconstructed with Filtered Back Projection or Iterative Reconstruction Algorithm
    Shin, Yoon Joo
    Chang, Won
    Ye, Jong Chul
    Kang, Eunhee
    Oh, Dong Yul
    Lee, Yoon Jin
    Park, Ji Hoon
    Kim, Young Hoon
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (03) : 356 - 364
  • [45] Impact of adaptive iterative dose reduction (AIDR) 3D on low-dose abdominal CT: comparison with routine-dose CT using filtered back projection
    Matsuki, Mitsuru
    Murakami, Takamichi
    Juri, Hiroshi
    Yoshikawa, Shushi
    Narumi, Yoshifumi
    ACTA RADIOLOGICA, 2013, 54 (08) : 869 - 875
  • [46] Ultra-low dose CT colonography with automatic tube current modulation and sinogram-affirmed iterative reconstruction: Effects on radiation exposure and image quality
    Cianci, Roberta
    Pizzi, Andrea Delli
    Esposito, Gianliugi
    Timpani, Mauro
    Tavoletta, Alessandra
    Pulsone, Pierluigi
    Basilico, Raffaella
    Cotroneo, Antonio Raffaele
    Filippone, Antonella
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 321 - 330
  • [47] Reducing Radiation Dose at Chest CT: Comparison Among Model-based Type Iterative Reconstruction, Hybrid Iterative Reconstruction, and Filtered Back Projection
    de Margerie-Mellon, Constance
    de Bazelaire, Cedric
    Montlahuc, Claire
    Lambert, Jerome
    Martineau, Antoine
    Coulon, Philippe
    de Kerviler, Eric
    Beigeman, Catherine
    ACADEMIC RADIOLOGY, 2016, 23 (10) : 1246 - 1254
  • [48] Image quality of CT angiography in young children with congenital heart disease: a comparison between the sinogram-affirmed iterative reconstruction (SAFIRE) and advanced modelled iterative reconstruction (ADMIRE) algorithms
    Nam, S. B.
    Jeong, D. W.
    Choo, K. S.
    Nam, K. J.
    Hwang, J. -Y.
    Lee, J. W.
    Kim, J. Y.
    Lim, S. J.
    CLINICAL RADIOLOGY, 2017, 72 (12) : 1060 - 1065
  • [49] Reaching for better image quality and lower radiation dose in head and neck CT: advanced modeled and sinogram-affirmed iterative reconstruction in combination with tube voltage adaptation
    Schmid, Andrea I.
    Uder, Michael
    Lell, Michael M.
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 46 (01)
  • [50] Image quality and radiation dose of CT venography with double dose reduction using model based iterative reconstruction: comparison with conventional CT venography using filtered back projection
    Jeong, Yeo-Jin
    Choo, Ki Seok
    Nam, Kyung Jin
    Lee, Ji Won
    Kim, Jin You
    Jung, Hyuk Jae
    Lim, Soo Jin
    ACTA RADIOLOGICA, 2018, 59 (05) : 546 - 552