Comparison study of image quality between filtered back projection and iterative reconstruction algorithm for dose reduction in chest CT

被引:0
|
作者
Son, Junyoung [1 ]
Lee, Donghoon [1 ]
Jeon, Pil-Hyun [2 ,3 ]
Choi, Sunghoon [3 ]
Kim, Hyemi [3 ]
Kim, Hee-Joung [1 ,3 ]
机构
[1] Yonsei Univ, Dept Radiat Convergence Engn, Wonju, South Korea
[2] Yonsei Univ, Wonju Severance Christian Hosp, Dept Radiol, Wonju, South Korea
[3] Radiol Sci Coll Hlth Sci Wonju, Wonju, South Korea
关键词
RADIATION;
D O I
10.1117/12.2521248
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Many studies have shown that iterative reconstruction (IR) algorithm is possible to make the tube current and/or voltage in CT imaging lower without a major loss of image quality. However, there are not many studies on the acquisition conditions for low dose CT images using IR algorithm to achieve the same image quality as routine dose images using FBP algorithm. The aim of this study was to investigate the image quality of low dose CT images obtained with IR algorithm. Images were reconstructed with filtered back projection (FBP) and iDose(4) hybrid IR algorithm (Philips Healthcare, Cleveland, OH). CTDIvol for routine protocol and low dose protocol were 5.2 mGy, and 2 mGy, respectively. Images were quantitatively assessed through Hounsfield unit (HU), noise power spectrum (NPS) and contrast to noise ratio (CNR). The results showed that image quality of iDose4 algorithm was improved than that of FBP algorithm. When the same low-dose protocol is used, the IR algorithm provided improved imaging performance compared with the FBP algorithm, and also demonstrated that IR algorithm provides potential for maintaining or improving image quality with much less radiation dose than FBP algorithm with routine dose.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Patient dose and image quality in low-dose abdominal CT: a comparison between iterative reconstruction and filtered back projection
    Kataria, Bharti
    Smedby, Orjan
    [J]. ACTA RADIOLOGICA, 2013, 54 (05) : 540 - 548
  • [2] Dose reduction in chest CT: Comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques
    Yamada, Yoshitake
    Jinzaki, Masahiro
    Hosokawa, Takahiro
    Tanami, Yutaka
    Sugiura, Hiroaki
    Abe, Takayuki
    Kuribayashi, Sachio
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) : 4185 - 4195
  • [3] Evaluation of dose reduction and image quality in CT colonography: Comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection
    Koichi Nagata
    Masanori Fujiwara
    Hidenori Kanazawa
    Tomohiro Mogi
    Nao Iida
    Toru Mitsushima
    Alan T. Lefor
    Hideharu Sugimoto
    [J]. European Radiology, 2015, 25 : 221 - 229
  • [4] Evaluation of dose reduction and image quality in CT colonography: Comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection
    Nagata, Koichi
    Fujiwara, Masanori
    Kanazawa, Hidenori
    Mogi, Tomohiro
    Iida, Nao
    Mitsushima, Toru
    Lefor, Alan T.
    Sugimoto, Hideharu
    [J]. EUROPEAN RADIOLOGY, 2015, 25 (01) : 221 - 229
  • [5] Low-Dose Computed Tomography of the Chest Using Iterative Reconstruction Versus Filtered Back Projection: Comparison of Image Quality
    Lee, Youkyung
    Jin, Kwang Nam
    Lee, Nyoung Keun
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (05) : 512 - 517
  • [6] Submillisievert Chest CT With Filtered Back Projection and Iterative Reconstruction Techniques
    Padole, Atul
    Singh, Sarabjeet
    Ackman, Jeanne B.
    Wu, Carol
    Do, Synho
    Pourjabbar, Sarvenaz
    Khawaja, Ranish Deedar Ali
    Otrakji, Alexi
    Digumarthy, Subba
    Shepard, Jo-Anne
    Kalra, Mannudeep
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (04) : 772 - 781
  • [7] Image quality and radiation dose of CT venography with double dose reduction using model based iterative reconstruction: comparison with conventional CT venography using filtered back projection
    Jeong, Yeo-Jin
    Choo, Ki Seok
    Nam, Kyung Jin
    Lee, Ji Won
    Kim, Jin You
    Jung, Hyuk Jae
    Lim, Soo Jin
    [J]. ACTA RADIOLOGICA, 2018, 59 (05) : 546 - 552
  • [8] A comparison between filtered back projection SPECT reconstruction and a new iterative reconstruction algorithm: A phantom study
    Zoccarato, O.
    Campini, R.
    Marcassa, C.
    Calza, P.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S237 - S237
  • [9] Pediatric Head CT Image Quality With Iterative Reconstruction Versus Filtered Back Projection
    Oberle, R.
    Kim, E.
    Wu, I.
    Ho, C.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [10] Adaptive Iterative Dose Reduction Algorithm in CT: Effect on Image Quality Compared with Filtered Back Projection in Body Phantoms of Different Sizes
    Kim, Milim
    Lee, Jeong Min
    Yoon, Jeong Hee
    Son, Hyoshin
    Choi, Jin Woo
    Han, Joon Koo
    Choi, Byung Ihn
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (02) : 195 - 204