Low-Dose Computed Tomography of the Chest Using Iterative Reconstruction Versus Filtered Back Projection: Comparison of Image Quality

被引:26
|
作者
Lee, Youkyung [1 ]
Jin, Kwang Nam [1 ]
Lee, Nyoung Keun [2 ]
机构
[1] Seoul Metropolitan Govt Seoul Natl Univ, Boramae Med Ctr, Dept Radiol, Seoul 156010, South Korea
[2] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
关键词
lung; computed tomography; iterative reconstruction; radiation dose; image quality; CT; REDUCTION;
D O I
10.1097/RCT.0b013e318260ce39
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The purpose of this study was to compare image quality of iterative reconstruction (IR) to filtered back projection (FBP) in low-dose computed tomography of the chest. Methods: Forty-three consecutive patients were retrospectively enrolled. Eight series of images were reconstructed using FBP and 7 levels of IR in each subject. Image noise, signal-to-noise ratio (SNR), and SNR improvement were measured. Two radiologists evaluated subjective artifact, image artificiality, and subjective overall image quality with 4- or 5-point scales. Results: Iterative reconstruction showed significantly lower image noise (135.5 +/- 36.6 vs 219.9 +/- 40.9) and higher SNR (0.36 +/- 0.12 vs 0.21 +/- 0.05) than FBP (P < 0.001). Signal-to-noise ratio improvement was 72.4% +/- 44.9%. Subjective artifact of FBP was significantly higher than IR images (P < 0.001). Image artificiality of IR was significantly higher than that of FBP (P < 0.001). Overall, subjective image quality was poor in FBP and acceptable or good in IR. Conclusions: With the use of IR, low-dose computed tomography of the chest would achieve less image noise and better image quality compared to the FBP.
引用
收藏
页码:512 / 517
页数:6
相关论文
共 50 条
  • [1] Low-Dose Chest Computed Tomography With Sinogram-Affirmed Iterative Reconstruction, Iterative Reconstruction in Image Space, and Filtered Back Projection: Studies on Image Quality
    Hwang, Hye Jeon
    Seo, Joon Beom
    Lee, Hyun Joo
    Lee, Sang Min
    Kim, Eun Young
    Oh, Sang Young
    Kim, Ji-Eun
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) : 610 - 617
  • [2] Raw-data-based iterative reconstruction versus filtered back projection: image quality of low-dose chest computed tomography examinations in 87 patients
    Wang, Haiyan
    Tan, Bingyi
    Zhao, Bin
    Liang, Changhu
    Xu, Zhuodong
    [J]. CLINICAL IMAGING, 2013, 37 (06) : 1024 - 1032
  • [3] Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients
    Pontana, Francois
    Duhamel, Alain
    Pagniez, Julien
    Flohr, Thomas
    Faivre, Jean-Baptiste
    Hachulla, Anne-Lise
    Remy, Jacques
    Remy-Jardin, Martine
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (03) : 636 - 643
  • [4] Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients
    François Pontana
    Alain Duhamel
    Julien Pagniez
    Thomas Flohr
    Jean-Baptiste Faivre
    Anne-Lise Hachulla
    Jacques Remy
    Martine Remy-Jardin
    [J]. European Radiology, 2011, 21 : 636 - 643
  • [5] Computed tomography of the cervical spine: comparison of image quality between a standard-dose and a low-dose protocol using filtered back-projection and iterative reconstruction
    Becce, Fabio
    Ben Salah, Yosr
    Verdun, Francis R.
    Vande Berg, Bruno C.
    Lecouvet, Frederic E.
    Meuli, Reto
    Omoumi, Patrick
    [J]. SKELETAL RADIOLOGY, 2013, 42 (07) : 937 - 945
  • [6] Computed tomography of the cervical spine: comparison of image quality between a standard-dose and a low-dose protocol using filtered back-projection and iterative reconstruction
    Fabio Becce
    Yosr Ben Salah
    Francis R. Verdun
    Bruno C. Vande Berg
    Frederic E. Lecouvet
    Reto Meuli
    Patrick Omoumi
    [J]. Skeletal Radiology, 2013, 42 : 937 - 945
  • [7] Comparison of image quality in pediatric head computed tomography reconstructed using blended iterative reconstruction versus filtered back projection
    Ho, Chang
    Oberle, Robert
    Wu, Isaac
    Kim, Eugene
    [J]. CLINICAL IMAGING, 2014, 38 (03) : 231 - 235
  • [8] Patient dose and image quality in low-dose abdominal CT: a comparison between iterative reconstruction and filtered back projection
    Kataria, Bharti
    Smedby, Orjan
    [J]. ACTA RADIOLOGICA, 2013, 54 (05) : 540 - 548
  • [9] Effects of Model-Based Iterative Reconstruction in Low-Dose Paranasal Computed Tomography: A Comparison with Filtered Back Projection and Hybrid Iterative Reconstruction
    Tomita, Hayato
    Kuramochi, Kenji
    Fujikawa, Atsuko
    Ikeda, Hirotaka
    Komita, Midori
    Kurihara, Yoshiko
    Kobayashi, Yasuyuki
    Mimura, Hidefumi
    [J]. ACTA MEDICA OKAYAMA, 2022, 76 (05) : 511 - 517
  • [10] Unenhanced computed tomography for normal appendix detection: comparison of low-dose with statistical iterative reconstruction and regular-dose with filtered back projection
    Park, Hwi Ryong
    Park, Sung Bin
    Lee, Eun Sun
    Park, Hyun Jeong
    Lee, Jong Beum
    Kim, Yang Soo
    [J]. CLINICAL IMAGING, 2017, 43 : 117 - 121