Dose reduction in chest CT: Comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques

被引:128
|
作者
Yamada, Yoshitake [1 ]
Jinzaki, Masahiro [1 ]
Hosokawa, Takahiro [1 ]
Tanami, Yutaka [1 ]
Sugiura, Hiroaki [1 ]
Abe, Takayuki [2 ]
Kuribayashi, Sachio [1 ]
机构
[1] Keio Univ, Sch Med, Dept Diagnost Radiol, Shinjuku Ku, Tokyo 1608582, Japan
[2] Keio Univ, Sch Med, Clin Res Ctr, Shinjuku Ku, Tokyo 1608582, Japan
关键词
Iterative reconstruction; Chest; Computed tomography (CT); Image quality; Low dose; Radiation exposure; COMPUTED-TOMOGRAPHY; FEASIBILITY;
D O I
10.1016/j.ejrad.2012.07.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To assess the effectiveness of adaptive iterative dose reduction (AIDR) and AIDR 3D in improving the image quality in low-dose chest CT (LDCT). Materials and methods: Fifty patients underwent standard-dose chest CT (SDCT) and LDCT simultaneously, performed under automatic exposure control with noise index of 19 and 38 (for a 2-mm slice thickness), respectively. The SDCT images were reconstructed with filtered back projection (SDCT-FBP images), and the LDCT images with FBP, AIDR and AIDR 3D (LDCT-FBP, LDCT-AIDR and LDCT-AIDR 3D images, respectively). On all the 200 lung and 200 mediastinal image series, objective image noise and signal-to-noise ratio (SNR) were measured in several regions, and two blinded radiologists independently assessed the subjective image quality. Wilcoxon's signed rank sum test with Bonferroni's correction was used for the statistical analyses. Results: The mean dose reduction in LDCT was 64.2% as compared with the dose in SDCT. LDCT-AIDR 3D images showed significantly reduced objective noise and significantly increased SNR in all regions as compared to the SDCT-FBP, LDCT-FBP and LDCT-AIDR images (all, P <= 0.003). In all assessments of the image quality, LDCT-AIDR 3D images were superior to LDCT-AIDR and LDCT-FBP images. The overall diagnostic acceptability of both the lung and mediastinal LDCT-AIDR 3D images was comparable to that of the lung and mediastinal SDCT-FBP images. Conclusions: AIDR 3D is superior to AIDR. Intra-individual comparisons between SDCT and LDCT suggest that AIDR 3D allows a 64.2% reduction of the radiation dose as compared to SDCT, by substantially reducing the objective image noise and increasing the SNR, while maintaining the overall diagnostic acceptability. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:4185 / 4195
页数:11
相关论文
共 50 条
  • [1] A comparison of adaptive iterative dose reduction 3D and filtered back projection in craniocervical CT angiography
    Yu, S.
    Zhang, L.
    Zheng, J.
    Xu, Y.
    Chen, Y.
    Song, Z.
    [J]. CLINICAL RADIOLOGY, 2017, 72 (01) : 96.e1 - 96.e6
  • [2] Adaptive Iterative Dose Reduction 3D Versus Filtered Back Projection in CT: Evaluation of Image Quality
    Joemai, Raoul M. S.
    Veldkamp, Wouter J. H.
    Kroft, Lucia J. M.
    Hernandez-Giron, Irene
    Geleijns, Jacob
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (06) : 1291 - 1297
  • [3] Impact of adaptive iterative dose reduction (AIDR) 3D on low-dose abdominal CT: comparison with routine-dose CT using filtered back projection
    Matsuki, Mitsuru
    Murakami, Takamichi
    Juri, Hiroshi
    Yoshikawa, Shushi
    Narumi, Yoshifumi
    [J]. ACTA RADIOLOGICA, 2013, 54 (08) : 869 - 875
  • [4] Standard dose versus low-dose abdominal and pelvic CT: Comparison between filtered back projection versus adaptive iterative dose reduction 3D
    Gervaise, A.
    Osemont, B.
    Louis, M.
    Lecocq, S.
    Teixeira, P.
    Blum, A.
    [J]. DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2014, 95 (01) : 47 - 53
  • [5] Dose reduction for chest CT: comparison of two iterative reconstruction techniques
    Pourjabbar, Sarvenaz
    Singh, Sarabjeet
    Kulkarni, Naveen
    Muse, Victorine
    Digumarthy, Subba R.
    Deedar, Ranish
    Khawaja, Ali
    Padole, Atul
    Do, Synho
    Kalra, Mannudeep K.
    [J]. ACTA RADIOLOGICA, 2015, 56 (06) : 688 - 695
  • [6] Comparison study of image quality between filtered back projection and iterative reconstruction algorithm for dose reduction in chest CT
    Son, Junyoung
    Lee, Donghoon
    Jeon, Pil-Hyun
    Choi, Sunghoon
    Kim, Hyemi
    Kim, Hee-Joung
    [J]. INTERNATIONAL FORUM ON MEDICAL IMAGING IN ASIA 2019, 2019, 11050
  • [7] Forward-Projected Model-Based Iterative Reconstruction in Screening Low-Dose Chest CT: Comparison With Adaptive Iterative Dose Reduction 3D
    Hassani, Cameron
    Ronco, Anthony
    Prosper, Ashley E.
    Dissanayake, Sumudu
    Cen, Steven Y.
    Lee, Christopher
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (03) : 548 - 556
  • [8] Adaptive iterative dose reduction 3D (AIDR 3D) vs. filtered back projection: radiation dose reduction capabilities of wide volume and helical scanning techniques on area-detector CT in a chest phantom study
    Seki, Shinichiro
    Koyama, Hisanobu
    Ohno, Yoshiharu
    Matsumoto, Sumiaki
    Inokawa, Hiroyasu
    Sugihara, Naoki
    Sugimura, Kazuro
    [J]. ACTA RADIOLOGICA, 2016, 57 (06) : 684 - 690
  • [9] Image quality of Adaptive Iterative Dose Reduction 3D of coronary CT angiography of 640-slice CT: comparison with filtered back-projection
    Roh-Eul Yoo
    Eun-Ah Park
    Whal Lee
    Hackjoon Shim
    Yeo Koon Kim
    Jin Wook Chung
    Jae Hyung Park
    [J]. The International Journal of Cardiovascular Imaging, 2013, 29 : 669 - 676
  • [10] Image quality of Adaptive Iterative Dose Reduction 3D of coronary CT angiography of 640-slice CT: comparison with filtered back-projection
    Yoo, Roh-Eul
    Park, Eun-Ah
    Lee, Whal
    Shim, Hackjoon
    Kim, Yeo Koon
    Chung, Jin Wook
    Park, Jae Hyung
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (03): : 669 - 676