Half-dose abdominal CT with sinogram-affirmed iterative reconstruction technique in children — comparison with full-dose CT with filtered back projection

被引:0
|
作者
Minwook Lee
Myung-Joon Kim
Kyung Hwa Han
Mi-Jung Lee
机构
[1] Yonsei University College of Medicine,Department of Radiology and Research Institute of Radiological Science, Severance Children’s Hospital
[2] Yonsei University College of Medicine,Gangnam Medical Research Center, Biostatistics Collaboration Unit
来源
Pediatric Radiology | 2015年 / 45卷
关键词
Computed tomography; Radiation dose; Image quality; Iterative reconstruction; Children;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:188 / 193
页数:5
相关论文
共 50 条
  • [21] Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography
    Chen, Guo Zhong
    Zhang, Long Jiang
    Schoepf, U. Joseph
    Wichmann, Julian L.
    Milliken, Cole M.
    Zhou, Chang Sheng
    Qi, Li
    Luo, Song
    Lu, Guang Ming
    EUROPEAN RADIOLOGY, 2015, 25 (05) : 1453 - 1463
  • [22] Radiation Dose Reduction With Sinogram Affirmed Iterative Reconstruction Technique for Abdominal Computed Tomography
    Kalra, Mannudeep K.
    Woisetschlager, Mischa
    Dahlstrom, Nils
    Singh, Sarabjeet
    Lindblom, Maria
    Choy, Garry
    Quick, Petter
    Schmidt, Bernhard
    Sedlmair, Martin
    Blake, Michael A.
    Persson, Anders
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (03) : 339 - 346
  • [23] Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography
    Guo Zhong Chen
    Long Jiang Zhang
    U. Joseph Schoepf
    Julian L. Wichmann
    Cole M. Milliken
    Chang Sheng Zhou
    Li Qi
    Song Luo
    Guang Ming Lu
    European Radiology, 2015, 25 : 1453 - 1463
  • [24] Evaluation of dose reduction and image quality in CT colonography: Comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection
    Koichi Nagata
    Masanori Fujiwara
    Hidenori Kanazawa
    Tomohiro Mogi
    Nao Iida
    Toru Mitsushima
    Alan T. Lefor
    Hideharu Sugimoto
    European Radiology, 2015, 25 : 221 - 229
  • [25] Evaluation of dose reduction and image quality in CT colonography: Comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection
    Nagata, Koichi
    Fujiwara, Masanori
    Kanazawa, Hidenori
    Mogi, Tomohiro
    Iida, Nao
    Mitsushima, Toru
    Lefor, Alan T.
    Sugimoto, Hideharu
    EUROPEAN RADIOLOGY, 2015, 25 (01) : 221 - 229
  • [26] Coronary plaque detection in low-dose CT: comparison of iterative reconstruction and filtered back projection
    Schmid, J.
    Layritz, C.
    Marwan, M.
    Mitschke, M.
    Pflederer, T.
    Ropers, D.
    Achenbach, S.
    Schuhbaeck, A.
    EUROPEAN HEART JOURNAL, 2014, 35 : 624 - 624
  • [27] Abdominal CT: Comparison of Adaptive Statistical Iterative and Filtered Back Projection Reconstruction Techniques
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Hsieh, Jiang
    Licato, Paul E.
    Do, Synho
    Pien, Homer H.
    Blake, Michael A.
    RADIOLOGY, 2010, 257 (02) : 373 - 383
  • [28] CARE Dose 4D combined with sinogram-affirmed iterative reconstruction improved the image quality and reduced the radiation dose in low dose CT of the small intestine
    Wang, Lin
    Gong, Shenchu
    Yang, Jushun
    Zhou, Jie
    Xiao, Jing
    Gu, Jin-hua
    Yang, Hong
    Zhu, Jianfeng
    He, Bosheng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 293 - 307
  • [29] Validation of Dual-Source Single-Tube Reconstruction as a Method to Obtain Half-Dose Images to Evaluate Radiation Dose and Noise Reduction: Phantom and Human Assessment Using CT Colonography and Sinogram-Affirmed Iterative Reconstruction (SAFIRE)
    Fletcher, Joel G.
    Grant, Katharine L. R.
    Fidler, Jeff L.
    Shiung, Maria
    Yu, Lifeng
    Wang, Jia
    Schmidt, Bernhard
    Allmendinger, Thomas
    McCollough, Cynthia H.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (05) : 560 - 569
  • [30] Dose Reduction in CT Trauma Brain Imaging Using Sinogram-Affirmed Iterative Reconstruction While Still Maintaining Diagnostic Image Quality
    Heaslip, I
    Hou, D.
    Keer, D.
    Hegarty, C.
    Louis, L.
    Nicolaou, S.