Half-dose abdominal CT with sinogram-affirmed iterative reconstruction technique in children — comparison with full-dose CT with filtered back projection

被引:0
|
作者
Minwook Lee
Myung-Joon Kim
Kyung Hwa Han
Mi-Jung Lee
机构
[1] Yonsei University College of Medicine,Department of Radiology and Research Institute of Radiological Science, Severance Children’s Hospital
[2] Yonsei University College of Medicine,Gangnam Medical Research Center, Biostatistics Collaboration Unit
来源
Pediatric Radiology | 2015年 / 45卷
关键词
Computed tomography; Radiation dose; Image quality; Iterative reconstruction; Children;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:188 / 193
页数:5
相关论文
共 50 条
  • [11] Comparison of Image Quality and Radiation Dose between Filtered Back Projection and Sinogram Affirmed Iterative Reconstruction in CT Head: A Cross-sectional Study
    Maggo, Kanchan
    Gupta, Rohini ghasi
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2024, 18 (10) : TC1 - TC6
  • [12] Low-Dose Chest Computed Tomography With Sinogram-Affirmed Iterative Reconstruction, Iterative Reconstruction in Image Space, and Filtered Back Projection: Studies on Image Quality
    Hwang, Hye Jeon
    Seo, Joon Beom
    Lee, Hyun Joo
    Lee, Sang Min
    Kim, Eun Young
    Oh, Sang Young
    Kim, Ji-Eun
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) : 610 - 617
  • [13] Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction
    Lee, So Won
    Kim, Yookyung
    Shim, Sung Shine
    Lee, Jeong Kyong
    Lee, Seok Jeong
    Ryu, Yon Ju
    Chang, Jung Hyun
    EUROPEAN RADIOLOGY, 2014, 24 (04) : 817 - 826
  • [14] Patient dose and image quality in low-dose abdominal CT: a comparison between iterative reconstruction and filtered back projection
    Kataria, Bharti
    Smedby, Orjan
    ACTA RADIOLOGICA, 2013, 54 (05) : 540 - 548
  • [15] Low-Dose CT With the Adaptive Statistical Iterative Reconstruction V Technique in Abdominal Organ Injury: Comparison With Routine-Dose CT With Filtered Back Projection
    Lee, Nam Kyung
    Kim, Suk
    Hong, Seung BaeK
    Kim, Tae Un
    Ryu, Hwaseong
    Lee, Ji Won
    Kim, Jin You
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (03) : 659 - 666
  • [16] Abdominal CT: Comparison of Low-Dose CT With Adaptive Statistical Iterative Reconstruction and Routine-Dose CT With Filtered Back Projection in 53 Patients
    Sagara, Yoshiko
    Hara, Amy K.
    Pavlicek, William
    Silva, Alvin C.
    Paden, Robert G.
    Wu, Qing
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 713 - 719
  • [17] Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction
    So Won Lee
    Yookyung Kim
    Sung Shine Shim
    Jeong Kyong Lee
    Seok Jeong Lee
    Yon Ju Ryu
    Jung Hyun Chang
    European Radiology, 2014, 24 : 817 - 826
  • [18] What is the preferred strength setting of the sinogram-affirmed iterative reconstruction algorithm in abdominal CT imaging?
    Hardie A.D.
    Nelson R.M.
    Egbert R.
    Rieter W.J.
    Tipnis S.V.
    Radiological Physics and Technology, 2015, 8 (1) : 60 - 63
  • [19] Low-Dose High-Pitch CT Angiography of the Supraaortic Arteries Using Sinogram-Affirmed Iterative Reconstruction
    Beitzke, Dietrich
    Nolz, Richard
    Unterhumer, Sylvia
    Plank, Christina
    Weber, Michael
    Schernthaner, Ruediger
    Schoepf, Veronika
    Wolf, Florian
    Loewe, Christian
    PLOS ONE, 2014, 9 (06):
  • [20] Physician Preference Between Low-Dose Computed Tomography With a Sinogram-Affirmed Iterative Reconstruction Algorithm and Routine-Dose Computed Tomography With Filtered Back Projection in Abdominopelvic Imaging
    Hardie, Andrew D.
    Tipnis, Sameer V.
    Rieter, William J.
    Rissing, Michael S.
    De Cecco, Carlo N.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (06) : 932 - 936