Application of a variable filter for presampled modulation transfer function analysis with the edge method

被引:3
|
作者
Higashide R. [1 ,3 ]
Ichikawa K. [2 ]
Kunitomo H. [3 ]
Ohashi K. [3 ]
机构
[1] Graduate School of Medical Science, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, 920-0942, Ishikawa
[2] Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, 920-0942, Ishikawa
[3] Department of Radiology, Nagoya City University Hospital, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-0001, Aichi
关键词
Digital radiography; Edge method; Noise-reduction technique; Presampled modulation transfer function (MTF); Variable filter;
D O I
10.1007/s12194-015-0325-2
中图分类号
学科分类号
摘要
We devised a new noise filtering method to reduce the noise in the line spread function (LSF) for presampled modulation transfer function (MTF) analysis with the edge method. A filter was designed to reduce noise effectively using a position-dependent filter controlled by the boundary frequency b for low-pass filtering, which is calculated by 1/2d (d: distance from the LSF center). In this filtering process, strong filters with very low b can be applied to regions distant from the LSF center, and the region near the LSF center can be maintained simultaneously by a correspondingly high b. Presampled MTF accuracies derived by use of the proposed method and an edge spread function (ESF)-fitting method were compared by use of simulated ESFs with and without noise, resembling a computed radiography (CR) and an indirect-type flat panel detector (FPD), respectively. In addition, the edge images of clinical CR, indirect-type FPD, and direct-type FPD systems were examined. For a simulated ESF without noise, the calculated MTFs of the variable filtering method agreed precisely with the true MTFs. The excellent noise-reduction ability of the variable filter was demonstrated for all simulated noisy ESFs and those of three clinical systems. Although the ESF-fitting method provided excellent noise reduction only for the CR-like simulated ESF with noise, its noise elimination performance could not be demonstrated due to the lesser robustness of the fitting. © 2015, Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:320 / 330
页数:10
相关论文
共 50 条
  • [1] Effects of processing steps with an edge image on determining the presampled modulation transfer function
    Ye-seul Kim
    Hye-Suk Park
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2012, 61 : 135 - 140
  • [2] Effects of processing steps with an edge image on determining the presampled modulation transfer function
    Kim, Ye-seul
    Park, Hye-Suk
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (01) : 135 - 140
  • [3] Effect of noise levels of an edge image on determining the presampled modulation transfer function
    Wan, Wenbo
    Gao, Feng
    Zhao, Huijuan
    Zhang, Lixin
    Zhou, Zhongxing
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES VII, 2014, 8936
  • [4] Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image
    Buhr, E
    Günther-Kohfahl, S
    Neitzel, U
    MEDICAL PHYSICS, 2003, 30 (09) : 2323 - 2331
  • [5] An Improved Slanted-edge Method for Measuring Modulation Transfer Function Based on Edge-preserving Filter
    Nie, Saisai
    Ruan, Xiukai
    Cui, Guihua
    Lu, Weikuan
    FOURTEENTH INTERNATIONAL CONFERENCE ON GRAPHICS AND IMAGE PROCESSING, ICGIP 2022, 2022, 12705
  • [6] Edge-based modulation transfer function measurement method using a variable oversampling ratio
    Masaoka, Kenichiro
    OPTICS EXPRESS, 2021, 29 (23) : 37628 - 37638
  • [7] Analysis of Edge Method Accuracy and Practical Multidirectional Modulation Transfer Function Measurement
    Wu, Yongjie
    Xu, Wei
    Piao, Yongjie
    Yue, Wei
    APPLIED SCIENCES-BASEL, 2022, 12 (24):
  • [8] Influence of readout process on presampled modulation transfer function in computed radiography system
    Kawaji, Yasuyuki
    Toyofuku, Fukai
    Ideguchi, Tadamitsu
    Higashida, Yoshiharu
    OPTICAL ENGINEERING, 2012, 51 (11)
  • [10] A Simple Approach of Presampled Modulation Transfer Function Measurement Tested on the Phoenix Nanotom Scanner
    Ivashkov, D.
    Batranin, A.
    Mamyrbayev, T.
    III ALL-RUSSIAN SCIENTIFIC AND PRACTICAL CONFERENCE ON INNOVATIONS IN NON-DESTRUCTIVE TESTING (SIBTEST 2015), 2016, 671