Effects of processing steps with an edge image on determining the presampled modulation transfer function

被引:2
|
作者
Kim, Ye-seul [1 ]
Park, Hye-Suk
Kim, Hee-Joung
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju 220710, South Korea
关键词
Modulation transfer function (MTF); Edge spread function (ESF); Slanted edge device; Digital radiography system; DIGITAL RADIOGRAPHIC SYSTEMS; ACQUISITION DEVICES; QUANTUM EFFICIENCY; MTF; SLIT;
D O I
10.3938/jkps.61.135
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Several methods are available to measuring the presampled modulation transfer function (MTF) of a digital radiography system by using a slit camera, a slanted edge test device or a bar phantom. Many studies demonstrated the advantages of the edge method compared to the slit method. However, the method of processing to estimate the MTF is slightly different for each publication. The purpose of this study is to compare the effects of various processing steps with an edge image on estimating the presampled MTF. A digital image of a slanted edge test device was acquired and then examined using different image processing such as windowing the edge spread function (ESF), determining a region of interest (ROI) and locally smoothing the ESF data. The results of this study indicated that the impact of determining a ROI on the MTF is relatively modest and that the truncation of the ESF due to a finite window width causes an incorrect inflation error in the MTF estimate and loss of detail at high frequency. Moreover, the influence of ESF smoothing on the MTF is demonstrated, and more rigorous smoothing of the ESF produces a less noisy MTF and, consequently, a high data loss at high-frequency. In conclusion, an ESF processing technique can moderately impact the MTF estimates, and an adequate ROI and window width without a smoothing process is suggested.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 50 条
  • [1] Effects of processing steps with an edge image on determining the presampled modulation transfer function
    Ye-seul Kim
    Hye-Suk Park
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2012, 61 : 135 - 140
  • [2] Effect of noise levels of an edge image on determining the presampled modulation transfer function
    Wan, Wenbo
    Gao, Feng
    Zhao, Huijuan
    Zhang, Lixin
    Zhou, Zhongxing
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES VII, 2014, 8936
  • [3] Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image
    Buhr, E
    Günther-Kohfahl, S
    Neitzel, U
    MEDICAL PHYSICS, 2003, 30 (09) : 2323 - 2331
  • [4] Application of a variable filter for presampled modulation transfer function analysis with the edge method
    Higashide R.
    Ichikawa K.
    Kunitomo H.
    Ohashi K.
    Radiological Physics and Technology, 2015, 8 (2) : 320 - 330
  • [5] Influence of readout process on presampled modulation transfer function in computed radiography system
    Kawaji, Yasuyuki
    Toyofuku, Fukai
    Ideguchi, Tadamitsu
    Higashida, Yoshiharu
    OPTICAL ENGINEERING, 2012, 51 (11)
  • [6] Image processing in seawater based on measured modulation transfer function
    Yu, YF
    Lu, XL
    Wang, XM
    2003 IEEE PACIFIC RIM CONFERENCE ON COMMUNICATIONS, COMPUTERS, AND SIGNAL PROCESSING, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 2003, : 712 - 715
  • [7] A NEW METHOD FOR DETERMINING THE MODULATION-TRANSFER FUNCTION FROM EDGE TRACES
    FANG, L
    TIZIANI, HJ
    OPTIK, 1986, 74 (01): : 17 - 21
  • [8] A Simple Approach of Presampled Modulation Transfer Function Measurement Tested on the Phoenix Nanotom Scanner
    Ivashkov, D.
    Batranin, A.
    Mamyrbayev, T.
    III ALL-RUSSIAN SCIENTIFIC AND PRACTICAL CONFERENCE ON INNOVATIONS IN NON-DESTRUCTIVE TESTING (SIBTEST 2015), 2016, 671
  • [9] Measurement of the presampled two-dimensional modulation transfer function of digital imaging systems
    Fetterly, KA
    Hangiandreou, NJ
    Schueler, BA
    Ritenour, ER
    MEDICAL PHYSICS, 2002, 29 (05) : 913 - 921