Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image

被引:110
|
作者
Buhr, E
Günther-Kohfahl, S
Neitzel, U
机构
[1] PTB, D-38116 Braunschweig, Germany
[2] Philipps Med Syst, D-22335 Hamburg, Germany
关键词
modulation transfer function; digital radiography; edge image; image analysis;
D O I
10.1118/1.1598673
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Several methods for accurately deriving the presampled modulation transfer function (MTF) of a pixelated detector from the image of a slightly slanted edge have been described in the literature. In this paper we report on a simple variant of the edge method that produces sufficiently accurate MTF values for frequencies up to the Nyquist frequency limit of the detector with little effort in edge alignment and computation. The oversampled ESF is constructed in a very simple manner by rearranging the pixel data of N consecutive lines corresponding to a lateral shift of the edge by one pixel. A regular subsampling pitch is assumed for the oversampled ESF, which is given by the original pixel sampling distance divided by the integer number N. This allows the original data to be used for further computational analysis (differentiation and Fourier transform) without data preprocessing. Since the number of lines leading to an edge shift by one pixel generally is a fractional number rather than an integer, a systematic error may be introduced into the presampled MTF. Simulations and theoretical investigations show that this error is proportional to 1/N and increases with spatial frequency. For all frequencies up to the Nyquist limit, the relative error Delta MTF/MTF is smaller than 1/(2N). It can thus be kept below a given threshold by suitably selecting N, which furnishes a certain maximum edge angle. The method is especially useful for applications where the presampled MTF is needed only for frequencies up to the Nyquist frequency limit, such as the determination of the detective quantum efficiency (DQE). (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:2323 / 2331
页数:9
相关论文
共 50 条
  • [1] Effects of processing steps with an edge image on determining the presampled modulation transfer function
    Ye-seul Kim
    Hye-Suk Park
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2012, 61 : 135 - 140
  • [2] Effects of processing steps with an edge image on determining the presampled modulation transfer function
    Kim, Ye-seul
    Park, Hye-Suk
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (01) : 135 - 140
  • [3] Effect of noise levels of an edge image on determining the presampled modulation transfer function
    Wan, Wenbo
    Gao, Feng
    Zhao, Huijuan
    Zhang, Lixin
    Zhou, Zhongxing
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES VII, 2014, 8936
  • [4] Application of a variable filter for presampled modulation transfer function analysis with the edge method
    Higashide R.
    Ichikawa K.
    Kunitomo H.
    Ohashi K.
    Radiological Physics and Technology, 2015, 8 (2) : 320 - 330
  • [5] Simple method for modulation transfer function determination of digital imaging detectors from edge images
    Buhr, E
    Günther-Kohfahl, S
    Neitzel, U
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 877 - 884
  • [6] A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    Samei, E
    Flynn, MJ
    Reimann, DA
    MEDICAL PHYSICS, 1998, 25 (01) : 102 - 113
  • [7] A Simple Approach of Presampled Modulation Transfer Function Measurement Tested on the Phoenix Nanotom Scanner
    Ivashkov, D.
    Batranin, A.
    Mamyrbayev, T.
    III ALL-RUSSIAN SCIENTIFIC AND PRACTICAL CONFERENCE ON INNOVATIONS IN NON-DESTRUCTIVE TESTING (SIBTEST 2015), 2016, 671
  • [8] Deriving the modulation transfer function of CT from extremely noisy edge profiles
    Mori I.
    MacHida Y.
    Radiological Physics and Technology, 2009, 2 (1) : 22 - 32
  • [9] Measurement of the presampled two-dimensional modulation transfer function of digital imaging systems
    Fetterly, KA
    Hangiandreou, NJ
    Schueler, BA
    Ritenour, ER
    MEDICAL PHYSICS, 2002, 29 (05) : 913 - 921
  • [10] Influence of readout process on presampled modulation transfer function in computed radiography system
    Kawaji, Yasuyuki
    Toyofuku, Fukai
    Ideguchi, Tadamitsu
    Higashida, Yoshiharu
    OPTICAL ENGINEERING, 2012, 51 (11)