Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image

被引:109
|
作者
Buhr, E
Günther-Kohfahl, S
Neitzel, U
机构
[1] PTB, D-38116 Braunschweig, Germany
[2] Philipps Med Syst, D-22335 Hamburg, Germany
关键词
modulation transfer function; digital radiography; edge image; image analysis;
D O I
10.1118/1.1598673
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Several methods for accurately deriving the presampled modulation transfer function (MTF) of a pixelated detector from the image of a slightly slanted edge have been described in the literature. In this paper we report on a simple variant of the edge method that produces sufficiently accurate MTF values for frequencies up to the Nyquist frequency limit of the detector with little effort in edge alignment and computation. The oversampled ESF is constructed in a very simple manner by rearranging the pixel data of N consecutive lines corresponding to a lateral shift of the edge by one pixel. A regular subsampling pitch is assumed for the oversampled ESF, which is given by the original pixel sampling distance divided by the integer number N. This allows the original data to be used for further computational analysis (differentiation and Fourier transform) without data preprocessing. Since the number of lines leading to an edge shift by one pixel generally is a fractional number rather than an integer, a systematic error may be introduced into the presampled MTF. Simulations and theoretical investigations show that this error is proportional to 1/N and increases with spatial frequency. For all frequencies up to the Nyquist limit, the relative error Delta MTF/MTF is smaller than 1/(2N). It can thus be kept below a given threshold by suitably selecting N, which furnishes a certain maximum edge angle. The method is especially useful for applications where the presampled MTF is needed only for frequencies up to the Nyquist frequency limit, such as the determination of the detective quantum efficiency (DQE). (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:2323 / 2331
页数:9
相关论文
共 50 条
  • [21] A NEW METHOD FOR DETERMINING THE MODULATION-TRANSFER FUNCTION FROM EDGE TRACES
    FANG, L
    TIZIANI, HJ
    OPTIK, 1986, 74 (01): : 17 - 21
  • [22] Measurement of the Modulation Transfer Function of Infrared Imaging System by Modified Slant Edge Method
    Li, Hang
    Yang, Changxiang
    Shao, Jianbing
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2016, 20 (03) : 381 - 388
  • [24] Measurement and analysis of modulation transfer function of digital image sensors
    Yi-chin Fang
    Yih-fong Tzeng
    Kuo-Ying Wu
    Ho-Lin Tsay
    Po-Ming Lin
    Microsystem Technologies, 2022, 28 : 137 - 142
  • [25] Measurement and analysis of modulation transfer function of digital image sensors
    Fang, Yi-Chin
    Tzeng, Yih-Fong
    Wu, Kuo-Ying
    Tsay, Ho-Lin
    Lin, Po-Ming
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2022, 28 (01): : 137 - 142
  • [26] Effect of the Edge Tool on Modulation Transfer Function Measurement in Digital Mammography
    Karaaslan, Melike Kaya
    Gundogdu, Ozcan
    Muzoglu, Nedim
    TIP TEKNOLOJILERI KONGRESI (TIPTEKNO'21), 2021,
  • [27] New method to improve measurement accuracy of modulation transfer function
    Song, Zongxi
    Gao, Wei
    Zhou, Yan
    Liu, Feng
    5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, 2010, 7656
  • [28] Modulation transfer function measurement of image motion of aerial camera based on slanted-edge method
    Sun, Chongshang
    Wang, Qi
    Ding, Yalin
    Wang, Dejiang
    Meng, Fanhao
    Zhang, Lei
    Guangxue Xuebao/Acta Optica Sinica, 2014, 34 (12):
  • [29] Investigating the impact of ghost images on the accuracy of modulation transfer function measurement using knife-edge method
    Ryu, Dongok
    Kim, Seonghui
    Seong, Sehyun
    Seo, Hyunju
    Youk, Youngchun
    Kim, Goeun
    Kim, Shinwook
    Yoon, Jeeyeon
    Lee, Deog Gyu
    Heo, Haeng Pal
    UV/OPTICAL/IR SPACE TELESCOPES AND INSTRUMENTS: INNOVATIVE TECHNOLOGIES AND CONCEPTS XI, 2023, 12676
  • [30] METHOD TO STUDY THE EFFECT OF CONTROLLED CHANGES OF BREAST IMAGE TOTAL SYSTEM MODULATION TRANSFER-FUNCTION (MTF) ON DIAGNOSTIC-ACCURACY
    BENCOMO, JA
    HAUS, AG
    PAULUS, DD
    HILL, CA
    LOGAN, WW
    JOHNSTON, DA
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 347 : 84 - 89