Measurement of the Modulation Transfer Function of Infrared Imaging System by Modified Slant Edge Method

被引:24
|
作者
Li, Hang [1 ,2 ]
Yang, Changxiang [1 ]
Shao, Jianbing [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
Modulation transfer function; Slant edge method; Infrared imaging system; Edge angle; Edge spread function; ARRAY;
D O I
10.3807/JOSK.2016.20.3.381
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The performance of a staring infrared imaging system can be characterized based on estimating the modulation transfer function (MTF). The slant edge method is a widely used MTF estimation method, which can effectively solve the aliasing problem caused by the discrete undersampling of the infrared focal plane array. However, the traditional slant edge method has some limitations such as the low precision of the edge angle extraction and using the approximate function to fit the edge spread function (ESF), which affects the accuracy of the MTF estimation. In this paper, we propose a modified slant edge method, including an edge angle extraction method that can improve the precision of the edge angle extraction and an ESF fitting algorithm which is based on the transfer function model of the imaging system, to enhance the accuracy of the MTF estimation. This modified slant edge method presents higher estimation accuracy and better immunity to noise and edge angle than other traditional methods, which is demonstrated by the simulation and application experiments operated in our study.
引用
收藏
页码:381 / 388
页数:8
相关论文
共 50 条
  • [1] The research on Modulation Transfer Function of underwater imaging system based on Edge Method
    Li, Dailin
    Li, Guilei
    Yang, Dan
    Xing, Yi
    Wang, Ning
    Zhu, Huafeng
    Jiao, Zhiyong
    OCEAN OPTICS AND INFORMATION TECHNOLOGY, 2018, 10850
  • [2] Automatic measurement method for modulation transfer function in infrared imaging system based on non-specific images
    Tang D.
    Cui R.
    Di J.
    Yu J.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2022, 43 (07): : 267 - 278
  • [3] Modulation transfer function measurement method of electro-optical imaging system
    Xu B.
    Shi Z.
    Feng B.
    Guangxue Xuebao/Acta Optica Sinica, 2011, 31 (11): : 1111004 - 1
  • [4] MODULATION TRANSFER-FUNCTION (MTF) MEASUREMENT OF THERMAL IMAGING-SYSTEM FROM THE EDGE RESPONSE FUNCTION
    ZAJA, M
    PERSIN, A
    OPTICAL ENGINEERING, 1983, 22 (06) : 743 - 745
  • [5] Modified slanted-edge method and multidirectional modulation transfer function estimation
    Masaoka, Kenichiro
    Yamashita, Takayuki
    Nishida, Yukihiro
    Sugawara, Masayuki
    OPTICS EXPRESS, 2014, 22 (05): : 6040 - 6046
  • [6] Modified slanted-edge method to measure the modulation transfer function of camera
    Zhang, Haosu
    Li, Chuang
    Duan, Yaxuan
    OPTIK, 2018, 157 : 635 - 643
  • [7] An experimental study of the accuracy in measurement of modulation transfer function using an edge method
    Lee, Dong-Hoon
    Kim, Ye-seul
    Park, Hye-Suk
    Lee, Young-Jin
    Kim, Hee-Joung
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [8] Analysis of Edge Method Accuracy and Practical Multidirectional Modulation Transfer Function Measurement
    Wu, Yongjie
    Xu, Wei
    Piao, Yongjie
    Yue, Wei
    APPLIED SCIENCES-BASEL, 2022, 12 (24):
  • [9] Modulation transfer function measurement method for fiber optic imaging bundles
    Li, Hongsheng
    Chen, Bingquan
    Feng, Keyan
    Ma, Hongyang
    OPTICS AND LASER TECHNOLOGY, 2008, 40 (02): : 415 - 419
  • [10] Error of the slanted edge method for measuring the modulation transfer function of imaging systems
    Xie, Xufen
    Fan, Hongda
    Wang, Hongyuan
    Wang, Zebin
    Zou, Nianyu