A Biomechanical Study of Flanged Intrascleral Haptic Fixation of Three-Piece Intraocular Lenses

被引:18
|
作者
Ma, Kevin K. [1 ,2 ,3 ]
Yuan, Amy [1 ,2 ,3 ]
Sharifi, Sina [1 ,2 ,3 ]
Pineda, Roberto [1 ,2 ,3 ]
机构
[1] Harvard Med Sch, Dept Ophthalmol, Massachusetts Eye & Ear, 243 Charles St, Boston, MA 02114 USA
[2] Univ Washington, Dept Ophthalmol, Seattle, WA USA
[3] Harvard Med Sch, Schepens Eye Res Inst, Boston, MA USA
关键词
SUTURELESS SCLERAL FIXATION; AMERICAN-ACADEMY; VISUAL OUTCOMES; DOUBLE-NEEDLE; CHAMBER; IMPLANTATION; SUPPORT; ABSENCE; EYES;
D O I
10.1016/j.ajo.2021.02.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: Flanged intrascleral haptic fixation (FISHF) is a useful method for securing intraocular lenses (IOLs) in eyes without capsular support. Biomechanical studies were conducted to support the use of this technique. center dot DESIGN: Laboratory investigation. center dot METHODS: Haptics of 3-piece IOLs were passed through cadaveric human sclera using 30-and 27-gauge needles. Flanges were created by melting 1.0 mm from the haptic ends using cautery. The forces required to remove the flanged haptic from the sclera and disinsert the haptic from the optic were measured using a mechanical tester and a custom-fabricated mount. center dot RESULTS: The mean FISHF dislocation force using 30-gauge needles was greatest with the CT Lucia 602 (2.04 +/- 0.24 newtons [N]) compared to the LI61AO (0.93 +/- 0.41 N; P = .001), ZA9003 (0.70 +/- 0.34 N; P = < .001), and MA60AC (0.27 +/- 0.19 N; P < .001). Using 27-gauge needles with the CT Lucia resulted in a lower dislocation force (0.56 +/- 0.36 N; P < .001). The FISHF dislocation force was correlated with the flange to-needle diameter ratio (r = 0.975). The FISHF dislocation forces of the CT Lucia and LI61AO using 30-gauge needles were not significantly different from their hapticoptic disinsertion forces ( P = .79 and .27, respectively). There were no differences in flange diameters between 1.0 mm and 2.0 mm haptic melt lengths across the IOLs ( P = .15-.85). center dot CONCLUSIONS: These data strongly support the biomechanical stability of FISHF with the polyvinylidene fluoride haptics of the CT Lucia using small diameter instruments for the creation of an intrascleral tunnel. 1.0 mm of haptic may be the optimal melt length
引用
收藏
页码:45 / 52
页数:8
相关论文
共 50 条
  • [1] Outcomes of Flanged Intrascleral Haptic Fixation with CT Lucia Three-Piece Intraocular Lens
    Fan, Kenneth C.
    Patel, Nimesh A.
    Al-Khersan, Hasenin
    Townsend, Justin H.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2021, 52 (12): : 658 - 662
  • [2] Clinical observation of a modified technique for intrascleral fixation of flanged three-piece foldable intraocular lenses through a Hoffman pocket
    Ye, Hongfei
    Wu, Mengxiao
    Sun, Wan
    Lyu, Jiao
    Xu, Yu
    Fei, Ping
    Peng, Jie
    Jin, Haiying
    Zhao, Peiquan
    FRONTIERS IN MEDICINE, 2024, 11
  • [3] Intrascleral haptic fixation of intraocular lenses
    Scharioth, G. B.
    OPHTHALMOLOGE, 2014, 111 (03): : 224 - 228
  • [4] Intrascleral sutureless fixation of three-piece intraocular lens for aphakia management
    Ciloglu, Emine
    Unal, Fikret
    CUKUROVA MEDICAL JOURNAL, 2018, 43 (04): : 951 - 957
  • [5] Impact of scleral tunnel length on the position of intraocular lenses in flanged intrascleral haptic fixation
    Jun, Jong Hwa
    Kwak, Joon-Ho
    Park, Chang-Hyun
    Lee, Jiyeon
    Seong, Jueun
    Shim, Kyu Young
    Afshari, Natalie A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (08): : 840 - 846
  • [6] Three-point flanged optic piercing intrascleral fixation of multifocal intraocular lenses
    Eom, Youngsub
    Jeon, Hyun Sun
    Kim, Seong-Jae
    Kim, Dong Hyun
    Song, Jong Suk
    Kim, Dooho Brian
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2025, 73 (03) : 455 - 461
  • [7] Flanged Sutureless Intrascleral Fixation of Dislocated Hard 1-Piece Polymethyl Methacrylate Intraocular Lenses
    Walsh, Mark K.
    Williams, Mark T.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2023, 43 (06): : 1035 - 1038
  • [8] Refractive outcome and lens power calculation after intrascleral intraocular lens fixation: a comparison of three-piece and one-piece intrascleral fixation technique
    Schranz, Markus
    Reumueller, Adrian
    Kostolna, Klaudia
    Novotny, Caroline
    Schartmueller, Daniel
    Abela-Formanek, Claudette
    EYE AND VISION, 2023, 10 (01)
  • [9] Refractive outcome and lens power calculation after intrascleral intraocular lens fixation: a comparison of three-piece and one-piece intrascleral fixation technique
    Markus Schranz
    Adrian Reumüller
    Klaudia Kostolna
    Caroline Novotny
    Daniel Schartmüller
    Claudette Abela-Formanek
    Eye and Vision, 10
  • [10] Trocar-assisted intrascleral sutureless fixation of a dislocated three-piece sulcus intraocular lens
    Karadag, Remzi
    Gunes, Bahar
    Demiorok, Ahmet
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2017, 80 (06) : 393 - 395