A Biomechanical Study of Flanged Intrascleral Haptic Fixation of Three-Piece Intraocular Lenses

被引:18
|
作者
Ma, Kevin K. [1 ,2 ,3 ]
Yuan, Amy [1 ,2 ,3 ]
Sharifi, Sina [1 ,2 ,3 ]
Pineda, Roberto [1 ,2 ,3 ]
机构
[1] Harvard Med Sch, Dept Ophthalmol, Massachusetts Eye & Ear, 243 Charles St, Boston, MA 02114 USA
[2] Univ Washington, Dept Ophthalmol, Seattle, WA USA
[3] Harvard Med Sch, Schepens Eye Res Inst, Boston, MA USA
关键词
SUTURELESS SCLERAL FIXATION; AMERICAN-ACADEMY; VISUAL OUTCOMES; DOUBLE-NEEDLE; CHAMBER; IMPLANTATION; SUPPORT; ABSENCE; EYES;
D O I
10.1016/j.ajo.2021.02.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: Flanged intrascleral haptic fixation (FISHF) is a useful method for securing intraocular lenses (IOLs) in eyes without capsular support. Biomechanical studies were conducted to support the use of this technique. center dot DESIGN: Laboratory investigation. center dot METHODS: Haptics of 3-piece IOLs were passed through cadaveric human sclera using 30-and 27-gauge needles. Flanges were created by melting 1.0 mm from the haptic ends using cautery. The forces required to remove the flanged haptic from the sclera and disinsert the haptic from the optic were measured using a mechanical tester and a custom-fabricated mount. center dot RESULTS: The mean FISHF dislocation force using 30-gauge needles was greatest with the CT Lucia 602 (2.04 +/- 0.24 newtons [N]) compared to the LI61AO (0.93 +/- 0.41 N; P = .001), ZA9003 (0.70 +/- 0.34 N; P = < .001), and MA60AC (0.27 +/- 0.19 N; P < .001). Using 27-gauge needles with the CT Lucia resulted in a lower dislocation force (0.56 +/- 0.36 N; P < .001). The FISHF dislocation force was correlated with the flange to-needle diameter ratio (r = 0.975). The FISHF dislocation forces of the CT Lucia and LI61AO using 30-gauge needles were not significantly different from their hapticoptic disinsertion forces ( P = .79 and .27, respectively). There were no differences in flange diameters between 1.0 mm and 2.0 mm haptic melt lengths across the IOLs ( P = .15-.85). center dot CONCLUSIONS: These data strongly support the biomechanical stability of FISHF with the polyvinylidene fluoride haptics of the CT Lucia using small diameter instruments for the creation of an intrascleral tunnel. 1.0 mm of haptic may be the optimal melt length
引用
收藏
页码:45 / 52
页数:8
相关论文
共 50 条
  • [31] Comparison of flanged intrascleral intraocular lens fixation versus iris claw intraocular lens fixation: A retrospective study
    Kelkar, Aditya S.
    Kelkar, Jai A.
    Kothari, Akshay A.
    Kelkar, Shreekant B.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (11) : 1838 - 1842
  • [32] A clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lenses
    Wallin, TR
    Hinckley, M
    Nilson, C
    Olson, RJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (04) : 614 - 619
  • [33] Modified Flanged Intrascleral Fixation of Intraocular Lens for Vitreoretinal Surgeons
    Najafi, Mehdi
    Yamane, Shin
    Johnston, Richard H.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2020, 51 (02): : 125 - 127
  • [34] Transconjunctival sutureless intrascleral fixation of 3-piece intraocular lenses using a curved needle
    Genc, Selim
    Cakir, Hanefi
    Baykara, Mehmet
    Esen, Fehim
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (08): : 969 - 970
  • [35] Commentary: Comprehending haptic exteriorization in intrascleral haptic fixation of an intraocular lens
    Narang, Priya
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (08) : 750 - +
  • [36] Late-Onset Spontaneous Haptic Disinsertion from a Three-Piece Intraocular Lens
    Chuang, Chih-Chun
    Lee, Jiahn-Shing
    Lin, Ken-Kuo
    Hsiao, Ching-Hsi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2010, 54 (05) : 500 - 502
  • [37] Late-onset spontaneous haptic disinsertion from a three-piece intraocular lens
    Chih-Chun Chuang
    Jiahn-Shing Lee
    Ken-Kuo Lin
    Ching-Hsi Hsiao
    Japanese Journal of Ophthalmology, 2010, 54 : 500 - 502
  • [38] Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique
    Yamane, Shin
    Sato, Shimpei
    Maruyama-Inoue, Maiko
    Kadonosono, Kazuaki
    OPHTHALMOLOGY, 2017, 124 (08) : 1136 - 1142
  • [39] Haptic stability of intrascleral fixated posterior chamber intraocular lenses
    Kane, Steven
    Khurshid, Gibran Syed
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (09): : 2034 - 2034
  • [40] The Efficacy and Safety of Flanged Needleless Sutureless Intrascleral Intraocular Lens Fixation
    Wa, Christianne A.
    Walsh, Mark K.
    Stem, Maxwell
    Todorich, Bozho
    Wolfe, Jeremy D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)