A Biomechanical Study of Flanged Intrascleral Haptic Fixation of Three-Piece Intraocular Lenses

被引:18
|
作者
Ma, Kevin K. [1 ,2 ,3 ]
Yuan, Amy [1 ,2 ,3 ]
Sharifi, Sina [1 ,2 ,3 ]
Pineda, Roberto [1 ,2 ,3 ]
机构
[1] Harvard Med Sch, Dept Ophthalmol, Massachusetts Eye & Ear, 243 Charles St, Boston, MA 02114 USA
[2] Univ Washington, Dept Ophthalmol, Seattle, WA USA
[3] Harvard Med Sch, Schepens Eye Res Inst, Boston, MA USA
关键词
SUTURELESS SCLERAL FIXATION; AMERICAN-ACADEMY; VISUAL OUTCOMES; DOUBLE-NEEDLE; CHAMBER; IMPLANTATION; SUPPORT; ABSENCE; EYES;
D O I
10.1016/j.ajo.2021.02.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: Flanged intrascleral haptic fixation (FISHF) is a useful method for securing intraocular lenses (IOLs) in eyes without capsular support. Biomechanical studies were conducted to support the use of this technique. center dot DESIGN: Laboratory investigation. center dot METHODS: Haptics of 3-piece IOLs were passed through cadaveric human sclera using 30-and 27-gauge needles. Flanges were created by melting 1.0 mm from the haptic ends using cautery. The forces required to remove the flanged haptic from the sclera and disinsert the haptic from the optic were measured using a mechanical tester and a custom-fabricated mount. center dot RESULTS: The mean FISHF dislocation force using 30-gauge needles was greatest with the CT Lucia 602 (2.04 +/- 0.24 newtons [N]) compared to the LI61AO (0.93 +/- 0.41 N; P = .001), ZA9003 (0.70 +/- 0.34 N; P = < .001), and MA60AC (0.27 +/- 0.19 N; P < .001). Using 27-gauge needles with the CT Lucia resulted in a lower dislocation force (0.56 +/- 0.36 N; P < .001). The FISHF dislocation force was correlated with the flange to-needle diameter ratio (r = 0.975). The FISHF dislocation forces of the CT Lucia and LI61AO using 30-gauge needles were not significantly different from their hapticoptic disinsertion forces ( P = .79 and .27, respectively). There were no differences in flange diameters between 1.0 mm and 2.0 mm haptic melt lengths across the IOLs ( P = .15-.85). center dot CONCLUSIONS: These data strongly support the biomechanical stability of FISHF with the polyvinylidene fluoride haptics of the CT Lucia using small diameter instruments for the creation of an intrascleral tunnel. 1.0 mm of haptic may be the optimal melt length
引用
收藏
页码:45 / 52
页数:8
相关论文
共 50 条
  • [11] Visual and refractive outcomes of trocar-assisted intrascleral three-piece intraocular lens fixation
    Pellegrini, Marco
    Adamo, Ginevra
    Nardella, Michele
    Sarti, Laura
    Talli, Pietro Maria
    Nasini, Francesco
    Mura, Marco
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024,
  • [12] Postoperative decentration of three-piece silicone intraocular lenses
    Kimura, W
    Kimura, T
    Sawada, T
    Taguchi, H
    Hirokane, C
    Ohte, A
    Hitani, H
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 : 1277 - 1280
  • [13] Iris suture fixation of out-of-the-bag dislocated three-piece intraocular lenses
    Armonaite, Laura
    Lofgren, Stefan
    Behndig, Anders
    ACTA OPHTHALMOLOGICA, 2019, 97 (06) : 583 - 588
  • [14] Long-term outcomes of modified glued versus flanged intrascleral haptic fixation techniques for secondary intraocular lenses
    Amy Yuan
    Debarshi Mustafi
    Michael R. Banitt
    Kasra A. Rezaei
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 2887 - 2895
  • [15] Long-term outcomes of modified glued versus flanged intrascleral haptic fixation techniques for secondary intraocular lenses
    Yuan, Amy
    Mustafi, Debarshi
    Banitt, Michael R.
    Rezaei, Kasra A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (09) : 2887 - 2895
  • [16] Intrascleral haptic fixation of intraocular lenses [Intrasklerale Haptikfixation von Intraokularlinsen]
    Scharioth G.B.
    Der Ophthalmologe, 2014, 111 (3): : 224 - 228
  • [17] Outcomes of one hundred and fifteen consecutive scleral fixated intraocular lenses using the 'yamane' flanged intrascleral haptic fixation technique
    Rocke, John
    Atkins, William
    McGuinness, Myra
    Fry, Lewis
    Kane, Jack
    Fabinyi, David
    Yeoh, Jonathan
    Chiu, Daniel
    Essex, Rohan
    Roufail, Edward
    Sheridan, Amy
    Edwards, Thomas
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 47 : 46 - 47
  • [18] A Modified Flanged Intrascleral Intraocular Lens Fixation Technique Using an Externalized Needle for Haptic Docking
    Ifantides, Cristos
    Naids, Steven M.
    Muttuvelu, Danson, V
    Mian, Shahzad, I
    Christopher, Karen L.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 2047 - 2050
  • [19] Sutureless intrascleral fixation using different three-piece posterior chamber intraocular lenses: a literature review of surgical techniques in cases of insufficient capsular support and a retrospective multicentre study
    Czajka, Marcin Piotr
    Frajdenberg, Agata
    Stopa, Marcin
    Pabin, Tomasz
    Johansson, Bjorn
    Jakobsson, Gunnar
    ACTA OPHTHALMOLOGICA, 2020, 98 (03) : 224 - 236
  • [20] Late spontaneous haptic disinsertion from a three-piece intraocular lens
    Solano, Joel M.
    Baratz, Keith H.
    Mahr, Michael A.
    Erie, Jay C.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (03) : 521 - 522