摘要
center dot PURPOSE: Flanged intrascleral haptic fixation (FISHF) is a useful method for securing intraocular lenses (IOLs) in eyes without capsular support. Biomechanical studies were conducted to support the use of this technique. center dot DESIGN: Laboratory investigation. center dot METHODS: Haptics of 3-piece IOLs were passed through cadaveric human sclera using 30-and 27-gauge needles. Flanges were created by melting 1.0 mm from the haptic ends using cautery. The forces required to remove the flanged haptic from the sclera and disinsert the haptic from the optic were measured using a mechanical tester and a custom-fabricated mount. center dot RESULTS: The mean FISHF dislocation force using 30-gauge needles was greatest with the CT Lucia 602 (2.04 +/- 0.24 newtons [N]) compared to the LI61AO (0.93 +/- 0.41 N; P = .001), ZA9003 (0.70 +/- 0.34 N; P = < .001), and MA60AC (0.27 +/- 0.19 N; P < .001). Using 27-gauge needles with the CT Lucia resulted in a lower dislocation force (0.56 +/- 0.36 N; P < .001). The FISHF dislocation force was correlated with the flange to-needle diameter ratio (r = 0.975). The FISHF dislocation forces of the CT Lucia and LI61AO using 30-gauge needles were not significantly different from their hapticoptic disinsertion forces ( P = .79 and .27, respectively). There were no differences in flange diameters between 1.0 mm and 2.0 mm haptic melt lengths across the IOLs ( P = .15-.85). center dot CONCLUSIONS: These data strongly support the biomechanical stability of FISHF with the polyvinylidene fluoride haptics of the CT Lucia using small diameter instruments for the creation of an intrascleral tunnel. 1.0 mm of haptic may be the optimal melt length
引用
收藏
页码:45 / 52
页数:8
相关论文
共 50 条
  • [41] Intraocular Lens Position Following In-the-Bag Implantation of Single-Piece Versus Three-Piece Acrylic Intraocular Lenses
    Robert, Marie-Claude
    Harasymowycz, Paul
    OPHTHALMIC SURGERY LASERS & IMAGING, 2012, 43 (06) : 472 - 478
  • [42] Potential role of the light-adjustable lens in flanged intrascleral haptic fixation
    Lobue, Stephen A.
    Saba, Nicholas
    Catapano, Thomas M.
    Martin, Curtis R.
    Shelby, Christopher L.
    Coleman III, Wyche T.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (07): : 754 - 759
  • [43] Sutureless Intrascleral Fixation of Intraocular Lenses: Three-Year Clinical Outcome Review
    Farley, Nathan
    Marlow, Elizabeth
    Gappy, Mavis
    Omar, Hamzeh
    Wolfe, Jeremy
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [44] ONE-YEAR OUTCOMES OF A NOVEL SURGICAL TECHNIQUE FOR SUTURELESS INTRASCLERAL FIXATION OF A THREE-PIECE INTRAOCULAR LENS USING A 30-GAUGE NEEDLE
    Bonnell, Alyssa C.
    Polo, Richard N.
    Shah, Sumit P.
    Fine, Howard F.
    Prenner, Jonathan L.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (06): : 1148 - 1152
  • [45] 4-Flanged intrascleral fixation of an intraocular lens through the dialing hole
    Vivekanandan, Vellam R.
    Nachiappan, Sivagami
    Benzy, Merlin
    Odayappan, Annamalai
    Venkatesh, Rengaraj
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (07) : 2897 - 2900
  • [46] Long-term follow-up of three-piece, looped, silicone intraocular lenses
    Milazzo, S
    Turut, P
    Artin, B
    Charlin, JF
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 : 1259 - 1262
  • [47] Intraocular lens implantation with flattened flanged intrascleral fixation technique in pediatric aphakia
    Ucar, Fikret
    JOURNAL OF AAPOS, 2022, 26 (01): : 8.e1 - 8.e7
  • [48] Intraocular Lens Formula Comparison of Flanged Intrascleral Intraocular Lens Fixation with Double Needle Technique
    Malach, Daniel S.
    Guest, John Michael
    Adam, Christopher
    Joffe, Jonah
    Le, Kim
    Kim, Chaesik
    Lin, Xihui
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 837 - 842
  • [49] Enhanced surgical technique for sutureless intrascleral fixation of intraocular lenses
    Gabai, Andrea
    Zeppieri, Marco
    Toneatto, Giacomo
    Salati, Carlo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (12): : E75 - E79
  • [50] Trocar-assisted flanged transconjunctival intrascleral sutureless intraocular lens fixation
    GamalElDin, Sherif A.
    ElShazly, Malak, I
    Salama, Marwa M.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (06) : 3699 - 3702