A Biomechanical Study of Flanged Intrascleral Haptic Fixation of Three-Piece Intraocular Lenses

被引:18
|
作者
Ma, Kevin K. [1 ,2 ,3 ]
Yuan, Amy [1 ,2 ,3 ]
Sharifi, Sina [1 ,2 ,3 ]
Pineda, Roberto [1 ,2 ,3 ]
机构
[1] Harvard Med Sch, Dept Ophthalmol, Massachusetts Eye & Ear, 243 Charles St, Boston, MA 02114 USA
[2] Univ Washington, Dept Ophthalmol, Seattle, WA USA
[3] Harvard Med Sch, Schepens Eye Res Inst, Boston, MA USA
关键词
SUTURELESS SCLERAL FIXATION; AMERICAN-ACADEMY; VISUAL OUTCOMES; DOUBLE-NEEDLE; CHAMBER; IMPLANTATION; SUPPORT; ABSENCE; EYES;
D O I
10.1016/j.ajo.2021.02.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: Flanged intrascleral haptic fixation (FISHF) is a useful method for securing intraocular lenses (IOLs) in eyes without capsular support. Biomechanical studies were conducted to support the use of this technique. center dot DESIGN: Laboratory investigation. center dot METHODS: Haptics of 3-piece IOLs were passed through cadaveric human sclera using 30-and 27-gauge needles. Flanges were created by melting 1.0 mm from the haptic ends using cautery. The forces required to remove the flanged haptic from the sclera and disinsert the haptic from the optic were measured using a mechanical tester and a custom-fabricated mount. center dot RESULTS: The mean FISHF dislocation force using 30-gauge needles was greatest with the CT Lucia 602 (2.04 +/- 0.24 newtons [N]) compared to the LI61AO (0.93 +/- 0.41 N; P = .001), ZA9003 (0.70 +/- 0.34 N; P = < .001), and MA60AC (0.27 +/- 0.19 N; P < .001). Using 27-gauge needles with the CT Lucia resulted in a lower dislocation force (0.56 +/- 0.36 N; P < .001). The FISHF dislocation force was correlated with the flange to-needle diameter ratio (r = 0.975). The FISHF dislocation forces of the CT Lucia and LI61AO using 30-gauge needles were not significantly different from their hapticoptic disinsertion forces ( P = .79 and .27, respectively). There were no differences in flange diameters between 1.0 mm and 2.0 mm haptic melt lengths across the IOLs ( P = .15-.85). center dot CONCLUSIONS: These data strongly support the biomechanical stability of FISHF with the polyvinylidene fluoride haptics of the CT Lucia using small diameter instruments for the creation of an intrascleral tunnel. 1.0 mm of haptic may be the optimal melt length
引用
收藏
页码:45 / 52
页数:8
相关论文
共 50 条
  • [21] Flattened flanged intrascleral intraocular lens fixation technique
    Ucar, Fikret
    Cetinkaya, Servet
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (06) : 1455 - 1460
  • [22] Short-term Clinical Outcomes after Flanged Intrascleral Fixation of Intraocular Lenses Using Oblique Intrascleral Tunnels
    Choi, Hyeon Gyu
    Kim, Yong-Kyu
    Park, Sung Pyo
    Kim, Yong Dae
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (07): : 557 - 565
  • [23] Flanged intrascleral intraocular lens fixation with a single needle
    Hwang, Eileen S.
    Warren, Clinton C.
    Koenig, Steven B.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (12): : 1526 - 1527
  • [24] Flattened flanged intrascleral intraocular lens fixation technique
    Fikret Ucar
    Servet Cetinkaya
    International Ophthalmology, 2020, 40 : 1455 - 1460
  • [25] Pars plana vitrectomy and scleral-fixated intraocular lenses: comparison of Gore-Tex suture and flanged intrascleral haptic fixation techniques
    Mahmoudzadeh, Raziyeh
    Oh, Glenn J.
    Patel, Neil
    Patel, Samir N.
    Tien, Thomas
    Xu, David
    Finklea, Brenton D.
    Gupta, Omesh P.
    Ayres, Brandon D.
    Khan, M. Ali
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2025, 60 (01): : e65 - e72
  • [26] Refractive Outcomes of the Yamane Flanged Intrascleral Haptic Fixation Technique
    Rocke, John R.
    McGuinness, Myra B.
    Atkins, William K.
    Fry, Lewis E.
    Kane, Jack X.
    Fabinyi, David C. A.
    Yeoh, Jonathan
    Chiu, Daniel
    Essex, Rohan W.
    Roufail, Edward
    Sheridan, Amy M.
    Allen, Penelope J.
    Edwards, Thomas L.
    OPHTHALMOLOGY, 2020, 127 (10) : 1429 - 1431
  • [27] Glued intrascleral haptic fixation of an intraocular lens
    Narang, Priya
    Agarwal, Amar
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (12) : 1370 - 1380
  • [28] Comparison of three different intraocular lens implantation techniques in the absence of capsular support: sutured scleral, haptic flanged intrascleral, and four flanged intrascleral fixations
    Ali Altan Ertan Boz
    Mahmut Atum
    Sedat Özmen
    İsa Yuvacı
    Erkan Çelik
    International Ophthalmology, 2023, 43 : 5045 - 5053
  • [29] Peripheral Intravascular Catheter-Assisted Sutureless Scleral Fixation of Three-Piece Intraocular Lenses: A Novel Technique
    Radice, Paolo
    Carini, Elisa
    Matteucci, Martina
    Ranno, Stefano
    Lucchini, Sara
    Govetto, Andrea
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2023, 43 (12): : 2096 - 2100
  • [30] Comparison of three different intraocular lens implantation techniques in the absence of capsular support: sutured scleral, haptic flanged intrascleral, and four flanged intrascleral fixations
    Boz, Ali Altan Ertan
    Atum, Mahmut
    Ozmen, Sedat
    Yuvaci, Isa
    Celik, Erkan
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (12) : 5045 - 5053