Refractive outcome and lens power calculation after intrascleral intraocular lens fixation: a comparison of three-piece and one-piece intrascleral fixation technique

被引:11
|
作者
Schranz, Markus [1 ]
Reumueller, Adrian [1 ]
Kostolna, Klaudia [1 ]
Novotny, Caroline [1 ]
Schartmueller, Daniel [1 ]
Abela-Formanek, Claudette [1 ]
机构
[1] Med Univ Vienna, Dept Ophthalmol & Optometry, Wahringer Gurtel 18-20, A-1090 Vienna, Austria
关键词
Secondary IOL; Refractive prediction error; IOL subluxation; Scleral IOL fixation; IOL power formulae; Secondary IOL tilt; Secondary IOL decentration; IMPLANTATION; ACCURACY; ABSENCE;
D O I
10.1186/s40662-023-00341-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo evaluate the refractive prediction error of common intraocular lens (IOL) power calculation formulae in patients who underwent intrascleral IOL fixation using two different techniques.MethodsThis is a prospective, randomized, longitudinal, single-site, single-surgeon study. Patients who underwent intrascleral IOL implantation using the Yamane or the Carlevale technique were followed up for a period of six months postoperatively. Refraction was measured using the best-corrected visual acuity at 4 m (EDTRS chart). Lens decentration, tilt and effective lens position (ELP) were assessed using an anterior segment optical coherence tomography (AS-OCT). The prediction error (PE) and the absolute error (AE) were evaluated for the SRK/T, Hollayday1 and Hoffer Q formula. Subsequently, correlations between the PE and axial length, keratometry, white to white and ELP were assessed.ResultsIn total, 53 eyes of 53 patients were included in the study. Twenty-four eyes of 24 patients were in the Yamane group (YG) and 29 eyes of 29 patients were in the Carlevale group (CG). In the YG, the Holladay 1 and Hoffer Q formulae resulted in a hyperopic PE (0.02 +/- 0.56 D, and 0.13 +/- 0.64 D, respectively) while in the SRK/T formula the PE was slightly myopic (- 0.16 +/- 0.56 D). In the CG, SRK/T and Holladay 1 formulae led to a myopic PE (- 0.1 +/- 0.80 D and - 0.04 +/- 0.74 D, respectively), Hoffer Q to a hyperopic PE (0.04 +/- 0.75 D). There was no difference between the PE of the same formulae across both groups (P > 0.05). In both groups the AE differed significantly from zero in each evaluated formula. The AE error was within +/- 0.50 D in 45%-71% and was within +/- 1.00 D in 72%-92% of eyes depending on the formula and surgical method used. No significant differences were found between formulae within and across groups (P > 0.05). Intraocular lens tilt was lower in the CG (6.45 +/- 2.03 degrees) compared to the YG (7.67 +/- 3.70 degrees) (P < 0.001). Lens decentration was higher in the YG (0.57 +/- 0.37 mm) than in the CG (0.38 +/- 0.21 mm), though the difference was not statistically significant (P = 0.9996).ConclusionsRefractive predictability was similar in both groups. IOL tilt was better in the CG, however this did not influence the refractive predictability. Though not significant, Holladay 1 formula seemed to be more probable than the SRK/T and Hoffer Q formulae. However, significant outliers were observed in all three different formulae and therefore remain a challenging task in secondary fixated IOLs.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Refractive outcome and lens power calculation after intrascleral intraocular lens fixation: a comparison of three-piece and one-piece intrascleral fixation technique
    Markus Schranz
    Adrian Reumüller
    Klaudia Kostolna
    Caroline Novotny
    Daniel Schartmüller
    Claudette Abela-Formanek
    Eye and Vision, 10
  • [2] Intrascleral sutureless fixation of three-piece intraocular lens for aphakia management
    Ciloglu, Emine
    Unal, Fikret
    CUKUROVA MEDICAL JOURNAL, 2018, 43 (04): : 951 - 957
  • [3] Visual and refractive outcomes of trocar-assisted intrascleral three-piece intraocular lens fixation
    Pellegrini, Marco
    Adamo, Ginevra
    Nardella, Michele
    Sarti, Laura
    Talli, Pietro Maria
    Nasini, Francesco
    Mura, Marco
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024,
  • [4] Outcomes of Flanged Intrascleral Haptic Fixation with CT Lucia Three-Piece Intraocular Lens
    Fan, Kenneth C.
    Patel, Nimesh A.
    Al-Khersan, Hasenin
    Townsend, Justin H.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2021, 52 (12): : 658 - 662
  • [5] Trocar-assisted intrascleral sutureless fixation of a dislocated three-piece sulcus intraocular lens
    Karadag, Remzi
    Gunes, Bahar
    Demiorok, Ahmet
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2017, 80 (06) : 393 - 395
  • [6] A Biomechanical Study of Flanged Intrascleral Haptic Fixation of Three-Piece Intraocular Lenses
    Ma, Kevin K.
    Yuan, Amy
    Sharifi, Sina
    Pineda, Roberto
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 227 : 45 - 52
  • [7] Refractive errors after sutureless intrascleral fixation of intraocular lens
    Kakisu, Masato
    Baba, Takayuki
    Tatsumi, Tomoaki
    Iwase, Takehito
    Nizawa, Tomohiro
    Miura, Gen
    Yamamoto, Shuichi
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (10) : 3003 - 3009
  • [8] Refractive Outcome, Lens Power Calculation, and Surgically Induced Astigmatism After Four-Flanged Intrascleral Intraocular Lens Fixation
    Schranz, Markus
    Lisy, Marcus
    Dimakopoulou, Ioanna
    Danzinger, Victor
    Schartmueller, Daniel
    Abela-Formanek, Claudette
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (12) : e985 - e993
  • [9] Refractive errors after sutureless intrascleral fixation of intraocular lens
    Masato Kakisu
    Takayuki Baba
    Tomoaki Tatsumi
    Takehito Iwase
    Tomohiro Nizawa
    Gen Miura
    Shuichi Yamamoto
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 3003 - 3009
  • [10] Refractive error induced by intraocular lens tilt after intrascleral intraocular lens fixation
    Tokuhisa, Teruaki
    Watanabe, Tomoyuki
    Watanabe, Akira
    Nakano, Tadashi
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (04) : 1213 - 1220