Refractive outcome and lens power calculation after intrascleral intraocular lens fixation: a comparison of three-piece and one-piece intrascleral fixation technique

被引:11
|
作者
Schranz, Markus [1 ]
Reumueller, Adrian [1 ]
Kostolna, Klaudia [1 ]
Novotny, Caroline [1 ]
Schartmueller, Daniel [1 ]
Abela-Formanek, Claudette [1 ]
机构
[1] Med Univ Vienna, Dept Ophthalmol & Optometry, Wahringer Gurtel 18-20, A-1090 Vienna, Austria
关键词
Secondary IOL; Refractive prediction error; IOL subluxation; Scleral IOL fixation; IOL power formulae; Secondary IOL tilt; Secondary IOL decentration; IMPLANTATION; ACCURACY; ABSENCE;
D O I
10.1186/s40662-023-00341-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo evaluate the refractive prediction error of common intraocular lens (IOL) power calculation formulae in patients who underwent intrascleral IOL fixation using two different techniques.MethodsThis is a prospective, randomized, longitudinal, single-site, single-surgeon study. Patients who underwent intrascleral IOL implantation using the Yamane or the Carlevale technique were followed up for a period of six months postoperatively. Refraction was measured using the best-corrected visual acuity at 4 m (EDTRS chart). Lens decentration, tilt and effective lens position (ELP) were assessed using an anterior segment optical coherence tomography (AS-OCT). The prediction error (PE) and the absolute error (AE) were evaluated for the SRK/T, Hollayday1 and Hoffer Q formula. Subsequently, correlations between the PE and axial length, keratometry, white to white and ELP were assessed.ResultsIn total, 53 eyes of 53 patients were included in the study. Twenty-four eyes of 24 patients were in the Yamane group (YG) and 29 eyes of 29 patients were in the Carlevale group (CG). In the YG, the Holladay 1 and Hoffer Q formulae resulted in a hyperopic PE (0.02 +/- 0.56 D, and 0.13 +/- 0.64 D, respectively) while in the SRK/T formula the PE was slightly myopic (- 0.16 +/- 0.56 D). In the CG, SRK/T and Holladay 1 formulae led to a myopic PE (- 0.1 +/- 0.80 D and - 0.04 +/- 0.74 D, respectively), Hoffer Q to a hyperopic PE (0.04 +/- 0.75 D). There was no difference between the PE of the same formulae across both groups (P > 0.05). In both groups the AE differed significantly from zero in each evaluated formula. The AE error was within +/- 0.50 D in 45%-71% and was within +/- 1.00 D in 72%-92% of eyes depending on the formula and surgical method used. No significant differences were found between formulae within and across groups (P > 0.05). Intraocular lens tilt was lower in the CG (6.45 +/- 2.03 degrees) compared to the YG (7.67 +/- 3.70 degrees) (P < 0.001). Lens decentration was higher in the YG (0.57 +/- 0.37 mm) than in the CG (0.38 +/- 0.21 mm), though the difference was not statistically significant (P = 0.9996).ConclusionsRefractive predictability was similar in both groups. IOL tilt was better in the CG, however this did not influence the refractive predictability. Though not significant, Holladay 1 formula seemed to be more probable than the SRK/T and Hoffer Q formulae. However, significant outliers were observed in all three different formulae and therefore remain a challenging task in secondary fixated IOLs.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Positive dysphotopsia after intrascleral intraocular lens fixation: a case report
    Mito, Tsuyoshi
    Kawakami, Honoka
    Ikoma, Toru
    Ukai, Yuki
    Tsuchiya, Mizuho
    Kubo, Eri
    Sasaki, Hiroshi
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [42] Positive dysphotopsia after intrascleral intraocular lens fixation: a case report
    Tsuyoshi Mito
    Honoka Kawakami
    Toru Ikoma
    Yuki Ukai
    Mizuho Tsuchiya
    Eri Kubo
    Hiroshi Sasaki
    BMC Ophthalmology, 22
  • [43] Refractive Outcomes after Sutureless Intrascleral Fixation of Secondary Intraocular Lens with Pars Plana Vitrectomy
    Lee, Ramon
    Farley, Nathan
    Abbey, Ashkan M.
    Stem, Maxwell S.
    Williams, George A.
    Faia, Lisa F.
    Hassan, Tarek S.
    Ruby, Alan J.
    Randhawa, Sandeep
    Wolfe, Jeremy D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [44] COMPARISON OF SCLERAL FIXATION OF INTRAOCULAR LENS Sutureless Intrascleral Fixation Versus Conventional Sutured Scleral Fixation
    Jang, Kyu Hwan
    Kong, Mingui
    Moon, Byung Gil
    Son, Gisung
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (04): : 761 - 767
  • [45] Intraocular lens implantation with flattened flanged intrascleral fixation technique in pediatric aphakia
    Ucar, Fikret
    JOURNAL OF AAPOS, 2022, 26 (01): : 8.e1 - 8.e7
  • [46] Intrascleral fixation of intraocular lens haptics: histological advantages in a comparison with scleral suture fixation in rabbits
    Hanemoto, Tsukasa
    Mukai, Koichiro
    Matsushima, Hiroyuki
    Senoo, Tadashi
    Kozawa, Tadahiko
    Takahashi, Yasuhiro
    Kakizaki, Hirohiko
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 257 (03) : 465 - 472
  • [47] Intrascleral fixation of intraocular lens haptics: histological advantages in a comparison with scleral suture fixation in rabbits
    Tsukasa Hanemoto
    Koichiro Mukai
    Hiroyuki Matsushima
    Tadashi Senoo
    Tadahiko Kozawa
    Yasuhiro Takahashi
    Hirohiko Kakizaki
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 : 465 - 472
  • [48] Sutureless Intrascleral Intraocular Lens Fixation Using a Microtube-assisted Technique
    Yuda, Kentaro
    Shimizu, Toshiki
    Hayashi, Takahiko
    Yuda, Kenji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [49] Assessing Refractive Stability after Cataract Surgery in Axial Myopes: One-piece and Three-piece Intraocular Lenses
    Lee, Ji Hye
    Cho, Yang Kyung
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (02): : 150 - 159
  • [50] Handshake technique for glued intrascleral haptic fixation of a posterior chamber intraocular lens
    Agarwal, Amar
    Jacob, Soosan
    Kumar, Dhivya Ashok
    Agarwal, Ashvin
    Narasimhan, Smita
    Agarwal, Athiya
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (03): : 317 - 322