Refractive outcome and lens power calculation after intrascleral intraocular lens fixation: a comparison of three-piece and one-piece intrascleral fixation technique

被引:11
|
作者
Schranz, Markus [1 ]
Reumueller, Adrian [1 ]
Kostolna, Klaudia [1 ]
Novotny, Caroline [1 ]
Schartmueller, Daniel [1 ]
Abela-Formanek, Claudette [1 ]
机构
[1] Med Univ Vienna, Dept Ophthalmol & Optometry, Wahringer Gurtel 18-20, A-1090 Vienna, Austria
关键词
Secondary IOL; Refractive prediction error; IOL subluxation; Scleral IOL fixation; IOL power formulae; Secondary IOL tilt; Secondary IOL decentration; IMPLANTATION; ACCURACY; ABSENCE;
D O I
10.1186/s40662-023-00341-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo evaluate the refractive prediction error of common intraocular lens (IOL) power calculation formulae in patients who underwent intrascleral IOL fixation using two different techniques.MethodsThis is a prospective, randomized, longitudinal, single-site, single-surgeon study. Patients who underwent intrascleral IOL implantation using the Yamane or the Carlevale technique were followed up for a period of six months postoperatively. Refraction was measured using the best-corrected visual acuity at 4 m (EDTRS chart). Lens decentration, tilt and effective lens position (ELP) were assessed using an anterior segment optical coherence tomography (AS-OCT). The prediction error (PE) and the absolute error (AE) were evaluated for the SRK/T, Hollayday1 and Hoffer Q formula. Subsequently, correlations between the PE and axial length, keratometry, white to white and ELP were assessed.ResultsIn total, 53 eyes of 53 patients were included in the study. Twenty-four eyes of 24 patients were in the Yamane group (YG) and 29 eyes of 29 patients were in the Carlevale group (CG). In the YG, the Holladay 1 and Hoffer Q formulae resulted in a hyperopic PE (0.02 +/- 0.56 D, and 0.13 +/- 0.64 D, respectively) while in the SRK/T formula the PE was slightly myopic (- 0.16 +/- 0.56 D). In the CG, SRK/T and Holladay 1 formulae led to a myopic PE (- 0.1 +/- 0.80 D and - 0.04 +/- 0.74 D, respectively), Hoffer Q to a hyperopic PE (0.04 +/- 0.75 D). There was no difference between the PE of the same formulae across both groups (P > 0.05). In both groups the AE differed significantly from zero in each evaluated formula. The AE error was within +/- 0.50 D in 45%-71% and was within +/- 1.00 D in 72%-92% of eyes depending on the formula and surgical method used. No significant differences were found between formulae within and across groups (P > 0.05). Intraocular lens tilt was lower in the CG (6.45 +/- 2.03 degrees) compared to the YG (7.67 +/- 3.70 degrees) (P < 0.001). Lens decentration was higher in the YG (0.57 +/- 0.37 mm) than in the CG (0.38 +/- 0.21 mm), though the difference was not statistically significant (P = 0.9996).ConclusionsRefractive predictability was similar in both groups. IOL tilt was better in the CG, however this did not influence the refractive predictability. Though not significant, Holladay 1 formula seemed to be more probable than the SRK/T and Hoffer Q formulae. However, significant outliers were observed in all three different formulae and therefore remain a challenging task in secondary fixated IOLs.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Influence of sclerotomy size on intraocular lens tilt after intrascleral intraocular lens fixation
    Matsumura, Takehiro
    Takamura, Yoshihiro
    Makita, Jun
    Kobori, Akira
    Inatani, Masaru
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1446 - 1451
  • [32] Comparison of flanged intrascleral intraocular lens fixation versus iris claw intraocular lens fixation: A retrospective study
    Kelkar, Aditya S.
    Kelkar, Jai A.
    Kothari, Akshay A.
    Kelkar, Shreekant B.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (11) : 1838 - 1842
  • [33] Surgical Technique for Sutureless Intrascleral Fixation of a 3-Piece Intraocular Lens Using a 30-Gauge Needle
    Bonnell, Alyssa C.
    Mantopoulos, Dimosthenis
    Wheatley, H. Matthew
    Prenner, Jonathan L.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 : 13 - 15
  • [34] Comparison of Refractive Prediction Error by Axial Length in Flanged Intrascleral Intraocular Lens Fixation
    Kabata, Yoshiaki
    Oki, Tetsutaro
    Nakano, Tadashi
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 895 - 900
  • [35] Facilitated trailing haptic externalization technique for intrascleral intraocular lens fixation
    Ucar, Fikret
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (01) : 615 - 620
  • [36] Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique
    Yamane, Shin
    Sato, Shimpei
    Maruyama-Inoue, Maiko
    Kadonosono, Kazuaki
    OPHTHALMOLOGY, 2017, 124 (08) : 1136 - 1142
  • [37] Sutureless transconjunctival intrascleral intraocular lens fixation: the modified Yamane technique
    Yavuzer, Kamil
    Evcimen, Yusuf
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2019, 82 (05) : 389 - 393
  • [38] IMPACT OF GAS/AIR TAMPONADE ON REFRACTIVE OUTCOMES AFTER FLANGED INTRASCLERAL INTRAOCULAR LENS FIXATION
    Tanaka, Yui
    Inoue, Tatsuya
    Mohamed, Shaheeda
    Yamaguchi, Takefumi
    Iwashita, Yume
    Hirono, Kazushi
    Nakamura, Kentaro
    Asaoka, Ryo
    Kobayashi, Shinobu
    Yamane, Shin
    Yanagi, Yasuo
    Maruyama-Inoue, Maiko
    Kadonosono, Kazuaki
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2023, 43 (10): : 1745 - 1749
  • [39] Modified Intraocular Lens Intrascleral Fixation Technique Using Two Vitrectomy Ports as Lens Haptic Fixation Sites
    Suzuki, Yukihiko
    Tando, Toshio
    Adachi, Kobu
    Kudo, Takashi
    Nakazawa, Mitsuru
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 1223 - 1228
  • [40] One-Year Outcomes of Modified Technique for Scleral Fixation of a Three-Piece Intraocular Lens Without Conjunctival Opening
    Ye, Hongfei
    Zhang, Shiguang
    Mi, Wei
    Fei, Ping
    Zhao, Peiquan
    FRONTIERS IN MEDICINE, 2022, 9