The efficacy of the arrow staple device for securing central venous catheters to human skin

被引:7
|
作者
Motonaga, GK [1 ]
Lee, KK [1 ]
Kirsch, JR [1 ]
机构
[1] Johns Hopkins Med Inst, Dept Anesthesiol & Crit Care Med, Baltimore, MD 21287 USA
来源
ANESTHESIA AND ANALGESIA | 2004年 / 99卷 / 05期
关键词
D O I
10.1213/01.ANE.0000132544.15467.10
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We tested the hypothesis that the force necessary to dislodge a central venous catheter from human skin is related to its method of attachment. Specifically, we compared the peak axial force and torque required to remove a catheter hub attached to human skin with 2 3-0 silk sutures, 4 0.022-in. staples, or 4 0.025-in. staples. We used the tissue from the proximal end of discarded extremities after below-knee amputations to serve as a surrogate for the skin of living humans that would normally be the site for catheter stabilization. Central venous catheter hubs were secured to the area of grossly normal appearing tissue with 2 3-0 silk sutures or 4 staples. For each attachment method, 16 dislodgement trials were conducted. The mean peak force required for axial dislodgement with 3-0 silk sutures (40.9 +/- 10.7 N; n = 16) was more than that for 40.022-in. staples (34.0 +/- 7.2 N; n = 16; P = 0.04) but was not different from that for 4 0.025-in. staples (40.4 +/- 5.8 N; n = 16). The major finding of this study is that securing a central venous hub with 4 0.025-in. staples is as effective as 2 3-0 silk sutures in preventing axial dislodgement.
引用
收藏
页码:1436 / 1439
页数:4
相关论文
共 50 条
  • [41] A device to stimulate central venous cannulation in the human patient simulator
    Eason, MP
    Goodrow, MS
    Gillespie, JE
    ANESTHESIOLOGY, 2003, 99 (05) : 1245 - 1246
  • [42] Effectiveness of securing central venous catheters with topical tissue adhesive in patients undergoing cardiac surgery: a randomized controlled pilot study
    Prachanpanich, Naruemol
    Morakul, Sunthiti
    Kiatmongkolkul, Napanont
    BMC ANESTHESIOLOGY, 2021, 21 (01)
  • [43] Effectiveness of securing central venous catheters with topical tissue adhesive in patients undergoing cardiac surgery: a randomized controlled pilot study
    Naruemol Prachanpanich
    Sunthiti Morakul
    Napanont Kiatmongkolkul
    BMC Anesthesiology, 21
  • [44] Erroneous placement of central venous catheters in subclavian artery: Retrieval and successful hemostasis with a femoral closure device
    Verloh, Niklas
    Scharf, Gregor
    Baeumler, Wolf
    Pfister, Karin
    Oikonomou, Kyriakos
    Stroszczynski, Christian
    Uller, Wibke
    Dollinger, Marco
    JOURNAL OF VASCULAR ACCESS, 2022, 23 (05): : 692 - 697
  • [45] Antimicrobial Efficacy of a New Chlorhexidine-based Device Against Staphylococcus aureus Colonization of Venous Catheters
    Kowalewska, Paulina M.
    Petrik, Shawn M.
    Di Fiore, Attilio E.
    Fox-Robichaud, Alison E.
    JOURNAL OF INFUSION NURSING, 2018, 41 (02) : 103 - 112
  • [46] Chlorhexidine dressing for reduction in microbial colonization of the skin with central venous catheters: a prospective randomized controlled trial
    Hanazaki, K
    Shingu, K
    Adachi, W
    Miyazaki, T
    Amano, J
    JOURNAL OF HOSPITAL INFECTION, 1999, 42 (02) : 165 - 168
  • [47] Failure to attain electrocardiogram-facilitated positioning of right atrial catheters when using the Arrow® Antecubital Central Venous Catheterization Kit
    Lanier, WL
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1998, 10 (04) : 241 - 243
  • [48] Efficacy of subcutaneous tunneling for prevention of bacterial colonization of femoral central venous catheters in critically ill children
    Nahum, E
    Levy, I
    Katz, J
    Samra, Z
    Ashkenazi, S
    Ben-Ari, J
    Schonfeld, T
    Dagan, O
    PEDIATRIC INFECTIOUS DISEASE JOURNAL, 2002, 21 (11) : 1000 - 1004
  • [49] Efficacy of Local Instillation of Recombinant Tissue Plasminogen Activator for Restoring Occluded Central Venous Catheters in Neonates
    Soylu, Hanifi
    Brandao, Leonardo R.
    Lee, Kyong-Soon
    JOURNAL OF PEDIATRICS, 2010, 156 (02): : 197 - U52
  • [50] Development of central venous access device-associated skin impairment assessment instrument
    Liu, Min
    Zheng, Chonghao
    Guan, Xiangyun
    Ke, Ziwei
    Zou, Ping
    Yang, Yeqin
    NURSING OPEN, 2022, 9 (04): : 2095 - 2107