The efficacy of the arrow staple device for securing central venous catheters to human skin

被引:7
|
作者
Motonaga, GK [1 ]
Lee, KK [1 ]
Kirsch, JR [1 ]
机构
[1] Johns Hopkins Med Inst, Dept Anesthesiol & Crit Care Med, Baltimore, MD 21287 USA
来源
ANESTHESIA AND ANALGESIA | 2004年 / 99卷 / 05期
关键词
D O I
10.1213/01.ANE.0000132544.15467.10
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We tested the hypothesis that the force necessary to dislodge a central venous catheter from human skin is related to its method of attachment. Specifically, we compared the peak axial force and torque required to remove a catheter hub attached to human skin with 2 3-0 silk sutures, 4 0.022-in. staples, or 4 0.025-in. staples. We used the tissue from the proximal end of discarded extremities after below-knee amputations to serve as a surrogate for the skin of living humans that would normally be the site for catheter stabilization. Central venous catheter hubs were secured to the area of grossly normal appearing tissue with 2 3-0 silk sutures or 4 staples. For each attachment method, 16 dislodgement trials were conducted. The mean peak force required for axial dislodgement with 3-0 silk sutures (40.9 +/- 10.7 N; n = 16) was more than that for 40.022-in. staples (34.0 +/- 7.2 N; n = 16; P = 0.04) but was not different from that for 4 0.025-in. staples (40.4 +/- 5.8 N; n = 16). The major finding of this study is that securing a central venous hub with 4 0.025-in. staples is as effective as 2 3-0 silk sutures in preventing axial dislodgement.
引用
收藏
页码:1436 / 1439
页数:4
相关论文
共 50 条
  • [21] CONTAMINATION OF CENTRAL VENOUS CATHETERS - THE SKIN INSERTION WOUND IS A MAJOR SOURCE OF CONTAMINATION
    EGEBO, K
    TOFT, P
    JAKOBSEN, CJ
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 115 - 115
  • [22] PREDICTIVE VALUE OF SURVEILLANCE SKIN AND HUB CULTURES IN CENTRAL VENOUS CATHETERS SEPSIS
    FAN, ST
    TEOHCHAN, CH
    LAU, KF
    CHU, KW
    KWAN, AKB
    WONG, KK
    JOURNAL OF HOSPITAL INFECTION, 1988, 12 (03) : 191 - 198
  • [23] Efficacy of silver-coating central venous catheters in reducing bacterial colonization
    Bach, A
    Eberhardt, H
    Frick, A
    Schmidt, H
    Böttiger, BW
    Martin, E
    CRITICAL CARE MEDICINE, 1999, 27 (03) : 515 - 521
  • [24] EFFICACY AND SAFETY OF A NEW TECHNIQUE OF CONVERSION OF TEMPORARY TO TUNNELED CENTRAL VENOUS CATHETERS
    Lomonte, Carlo
    Casucci, Francesco
    Libutti, Pasquale
    Lisi, Piero
    Basile, Carlo
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2014, 29 : 256 - 256
  • [25] Re: Sutureless securement device reduces complications of peripherally inserted central venous catheters
    Mermel, LA
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (08) : 855 - 855
  • [26] Evaluation of the Efficacy of a Novel Dermatotomy Device for Central Venous Cannulation
    Keeyapaj, Worasak
    Cheung, Albert T.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2024, 38 (09) : 1951 - 1956
  • [27] Skin and soft tissue complications in pediatric leukemia patients with and without central venous catheters
    Demircioglu, Fatih
    Yilmaz, Sebem
    Oren, Hale
    Ozguven, Ali Aykan
    Irken, Guelersu
    JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2008, 30 (01) : 32 - 35
  • [28] Contamination of central venous catheters. The skin insertion wound is a major source of contamination
    Egebo, K
    Toft, P
    Jakobsen, CJ
    JOURNAL OF HOSPITAL INFECTION, 1996, 32 (02) : 99 - 104
  • [29] Securing CSF catheters to the skin: from sutures and bolt system to subcutaneous anchoring device towards zero complications
    Frassanito, Paolo
    Auricchio, Anna Maria
    Antonucci, Jacopo
    Massimi, Luca
    Bianchi, Federico
    Tamburrini, Gianpiero
    CHILDS NERVOUS SYSTEM, 2020, 36 (11) : 2749 - 2755
  • [30] Securing CSF catheters to the skin: from sutures and bolt system to subcutaneous anchoring device towards zero complications
    Paolo Frassanito
    Anna Maria Auricchio
    Jacopo Antonucci
    Luca Massimi
    Federico Bianchi
    Gianpiero Tamburrini
    Child's Nervous System, 2020, 36 : 2749 - 2755