Volume-of-interest, (VOI) imaging in C-arm flat-detector CT for high image quality at reduced dose

被引:57
|
作者
Kolditz, Daniel [1 ]
Kyriakou, Yiannis [1 ]
Kalender, Willi A. [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
关键词
volume-of-interest (VOI) imaging; flat-detector CT (FDCT); C-arm CT; dose; image quality; BEAM BREAST CT; GUIDED RADIATION-THERAPY; COMPUTED-TOMOGRAPHY; PANEL DETECTOR; RECONSTRUCTION; REGION; FEASIBILITY; RESOLUTION; ALGORITHM; GUIDANCE;
D O I
10.1118/1.3427641
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A novel method for flat-detector computed tomography was developed to enable volume-of-interest (VOI) imaging at high resolution, low noise, and reduced dose. For this, a full low-dose overview (OV) scan and a local high-dose scan of a VOI are combined. Methods: The first scan yields an overview of the whole object and enables the selection of an arbitrary VOI. The second scan of that VOI assures high image quality within the interesting volume. The combination of the two consecutive scans is based on a forward projection of the reconstructed OV volume that was registered to the VOI. The artificial projection data of the OV scan are combined with the measured VOI data in the raw data domain. Different projection values are matched by an appropriate transformation and weighting. The reconstruction is performed with a standard Feldkamp-type algorithm. In simulations, the combination of OV scan and VOI scan was investigated on a mathematically described phantom. In measurements, spatial resolution and noise were evaluated with image quality phantoms. Modulation transfer functions and noise values were calculated. Measurements of an anthropomorphic head phantom were used to validate the proposed method for realistic applications, e. g., imaging stents. In Monte Carlo simulations, 3D dose distributions were calculated and dose values were assessed quantitatively. Results: By the proposed combination method, an image is generated which covers the whole object and provides the VOI at high image quality. In the OV image, a resolution of 0.7 lp/mm (line pairs per millimeter) and noise of 63.5 HU were determined. Inside the VOI, resolution was increased to 2.4 lp/mm and noise was decreased to 18.7 HU. For the performed measurements, the cumulative dose was significantly reduced in comparison to conventional scans by up to 93%. The dose of a high-quality scan, for example, was reduced from 97 to less than 7 mGy, while keeping image quality constant within the VOI. Conclusions: The proposed VOI application with two scans is an effective way to ensure high image quality within the VOI while simultaneously reducing the cumulative patient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3427641]
引用
收藏
页码:2719 / 2730
页数:12
相关论文
共 50 条
  • [1] Low Dose, Low Noise and High Resolution Volume of Interest (VOI) Imaging in C-Arm Flat-Detector CT
    Kolditz, Daniel
    Kyriakou, Yiannis
    Kalender, Willi A.
    [J]. MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [2] Low-Dose Volume-of-Interest C-Arm CT Imaging of Intracranial Stents and Flow Diverters
    Yang, P.
    Ahmed, A.
    Schafer, S.
    Niemann, D.
    Aagaard-Kienitz, B.
    Royalty, K.
    Strother, C.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (04) : 648 - 654
  • [3] Patient-bounded extrapolation using low-dose priors for volume-of-interest imaging in C-arm CT
    Xia, Y.
    Bauer, S.
    Maier, A.
    Berger, M.
    Hornegger, J.
    [J]. MEDICAL PHYSICS, 2015, 42 (04) : 1787 - 1796
  • [4] The Added Value of Volume-of-Interest C-Arm CT Imaging during Endovascular Treatment of Intracranial Aneurysms
    Chintalapani, G.
    Chinnadurai, P.
    Maier, A.
    Xia, Y.
    Bauer, S.
    Shaltoni, H.
    Morsi, H.
    Mawad, M. E.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (04) : 660 - 666
  • [5] Volume-of-interest (VOI) cone beam CT with dual resolution image acquisition
    Chen, L.
    Shaw, C.
    Meng, Y.
    Altunbas, M.
    Wang, T.
    Tu, S.
    Liu, X.
    Lai, C.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2000 - 2000
  • [6] The comparison of radiation dose between C-arm flat-detector CT (DynaCT) and multi-slice CT (MSCT): A phantom study
    Bai, Mei
    Liu, Bin
    Mu, Hongqiu
    Liu, Xianghua
    Jiang, Yuan
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3577 - 3580
  • [7] Preliminary performance of image quality for a low-dose C-arm CT system with a flat-panel detector
    Cha, Bo Kyung
    Seo, Chang-Woo
    Yang, Keedong
    Jeon, Seongchae
    Huh, Young
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 784 : 565 - 569
  • [8] Brain imaging with a flat detector C-arm
    Soederman, M.
    Babic, D.
    Holmin, S.
    Andersson, T.
    [J]. NEURORADIOLOGY, 2008, 50 (10) : 863 - 868
  • [9] Magnitude of Scattered Radiation and Dose Efficiency in Volume-Of-Interest (VOI) Cone Beam CT
    Lai, C.
    Chen, L.
    Han, T.
    Liu, X.
    Shen, Y.
    Wang, T.
    Shaw, C.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [10] Dose and Image Quality in C-Arm CT Rotational Angiography
    Fahrig, R.
    Girard-Hughes, E.
    Ganguly, A.
    Tognolini, A.
    Kothary, N.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3413 - 3414