Preliminary performance of image quality for a low-dose C-arm CT system with a flat-panel detector

被引:0
|
作者
Cha, Bo Kyung [1 ]
Seo, Chang-Woo [2 ]
Yang, Keedong [1 ]
Jeon, Seongchae [1 ]
Huh, Young [1 ]
机构
[1] Korea Electrotechnol Res Inst, Adv Med Device Res Ctr, Ansan, South Korea
[2] Yonsei Univ, Coll Hlth Sci, Dept Radiat Convergence Engn, Wonju, South Korea
关键词
Flat panel X-ray detector; CBCT system; C-arm -based tomography; 3D image reconstruction;
D O I
10.1016/j.nima.2014.12.105
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Digital flat panel imager (FPI)-based cone-beam computed tomography (CBCT) has been widely used in C-arm imaging for spine surgery and interventional procedures. The system provides real-time fluoroscopy with high spatial resolution and three-dimensional (3D) visualization of anatomical structure without the need for patient transportation in interventional suite. In this work, a prototype CBCT imaging platform with continuous single rotation about the gantry was developed by using a large-area flat-panel detector with amorphous Si-based thin film transistor matrix. The different 20 projection images were acquired during constant gantry velocity for reconstructed images at a tube voltage of 80-120 kVp, and different current (10-50 mA) conditions. Various scan protocols were applied to a chest phantom human by changing the number of projection images and scanning angles. The projections were then reconstructed into a volumetric data of sections by using a 3D reconstruction algorithm (e.g., filtered back projection). The preliminary quantitative X-ray performance of our CBCT system was investigated by using the American Association of Physicists in Medicine CT phantom in terms of spatial resolution, contrast resolution, and CT number linearity for mobile or fixed C-arm based CBCT application with limited rotational geometry. The novel results of the projection data with different scanning angles and angular increments in the orbital gantry platform were acquired and evaluated experimentally. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:565 / 569
页数:5
相关论文
共 50 条
  • [1] C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance
    Roman Guggenberger
    Erika J. Ulbrich
    Tobias J. Dietrich
    Rosemarie Scholz
    Pascal Kaelin
    Christoph Köhler
    Thilo Elsässer
    Thomas Le Corroller
    Thomas Pfammatter
    Hatem Alkadhi
    Gustav Andreisek
    [J]. European Radiology, 2017, 27 : 454 - 463
  • [2] C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance
    Guggenberger, Roman
    Ulbrich, Erika J.
    Dietrich, Tobias J.
    Scholz, Rosemarie
    Kaelin, Pascal
    Koehler, Christoph
    Elsaesser, Thilo
    Le Corroller, Thomas
    Pfammatter, Thomas
    Alkadhi, Hatem
    Andreisek, Gustav
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (02) : 454 - 463
  • [3] Percutaneous foot joint needle placement using a C-arm flat-panel detector CT
    Martin Wiewiorski
    Martin Thanh Long Takes
    Victor Valderrabano
    Augustinus Ludwig Jacob
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 177 - 180
  • [4] Optimization of X-ray image acquisition and reconstruction for a C-arm CBCT system with a flat-panel detector
    Cha, Bo Kyung
    Jeon, Seongchae
    Seo, Chang-Woo
    Back, Jongduck
    Choi, Shinkook
    Lee, Changwoo
    Ahn, Miseob
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 924 : 343 - 349
  • [5] Percutaneous foot joint needle placement using a C-arm flat-panel detector CT
    Wiewiorski, Martin
    Takes, Martin Thanh Long
    Valderrabano, Victor
    Jacob, Augustinus Ludwig
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (02) : 177 - 180
  • [6] Change your Angle of ViewSinusoidal C-Arm Movement in Cranial Flat-panel CT to Improve Image Quality
    Hannes Luecking
    Philip Hoelter
    Stefan Lang
    Manuel Schmidt
    Felix Eisenhut
    Arnd Doerfler
    [J]. Clinical Neuroradiology, 2022, 32 : 1109 - 1115
  • [7] Percutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcome
    Sung Eun Kang
    Joon Woo Lee
    Joo Hyung Kim
    Kun Woo Park
    Jin S. Yeom
    Heung Sik Kang
    [J]. Skeletal Radiology, 2011, 40 : 453 - 460
  • [8] Percutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcome
    Kang, Sung Eun
    Lee, Joon Woo
    Kim, Joo Hyung
    Park, Kun Woo
    Yeom, Jin S.
    Kang, Heung Sik
    [J]. SKELETAL RADIOLOGY, 2011, 40 (04) : 453 - 460
  • [9] Change your Angle of View Sinusoidal C-Arm Movement in Cranial Flat-panel CT to Improve Image Quality
    Luecking, Hannes
    Hoelter, Philip
    Lang, Stefan
    Schmidt, Manuel
    Eisenhut, Felix
    Doerfler, Arnd
    [J]. CLINICAL NEURORADIOLOGY, 2022, 32 (04) : 1109 - 1115
  • [10] A retrospective comparison of organ dose and effective dose in percutaneous vertebroplasty performed under CT guidance or using a fixed C-arm with a flat-panel detector
    Greffier, Joel
    Hamard, Aymeric
    Berny, Laure
    Snene, Fehmi
    Perolat, Romain
    Larbi, Ahmed
    Viala, Pierre
    Dabli, Djamel
    Beregi, Jean-Paul
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 88 : 235 - 241