Brain imaging with a flat detector C-arm

被引:66
|
作者
Soederman, M. [1 ]
Babic, D. [2 ]
Holmin, S. [1 ]
Andersson, T. [1 ]
机构
[1] Karolinska Hosp, Dept Neuroradiol, S-17176 Stockholm, Sweden
[2] Philips Med Syst, Best, Netherlands
关键词
computed tomography; interventional neuroradiology; angiography; cone-beam CT;
D O I
10.1007/s00234-008-0419-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction We present the first clinical results from brain tissue imaging with a novel functionality in the angiography room, the XperCT. Method XperCT is a flat detector C-arm volume acquisition functionality integrated with the angiography equipment. We assessed brain images from 42 patients examined with computed tomography (CT) and XperCT. Results In all patients, XperCT had significantly more beam hardening and reconstruction artifacts than CT, in particular in the posterior fossa. Contrast resolution was better on CT images. Hemorrhage, edema, and ventricular size could be assessed with XperCT in all patients, but CT was superior also in this aspect. In four of the last 12 cases, after the latest software upgrade, it was possible to differentiate between supra-tentorial grey and white substance on XperCT images. Conclusion CT was superior to XperCT regarding brain soft tissue imaging. However, XperCT could in some cases discriminate between grey and white substance. XperCT is a useful new functionality in interventional neuroradiology. In the clinical setting, it improves patient safety by allowing almost instant access to CT-like brain imaging in the angiography room. It can be life saving in situations where complications during an interventional procedure prompt for immediate action.
引用
收藏
页码:863 / 868
页数:6
相关论文
共 50 条
  • [1] Development of an Integrated C-Arm Interventional Imaging System With a Strip Photon Counting Detector and a Flat Panel Detector
    Ji, Xu
    Feng, Mang
    Treb, Kevin
    Zhang, Ran
    Schafer, Sebastian
    Li, Ke
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (12) : 3674 - 3685
  • [2] Artifact Reduction of Different Metallic Implants in Flat Detector C-Arm CT
    Hung, S. -C.
    Wu, C. -C.
    Lin, C. -J.
    Guo, W. -Y.
    Luo, C. -B.
    Chang, F. -C.
    Chang, C. -Y.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (07) : 1288 - 1292
  • [3] Reliability and Usefulness of Intraoperative 3-Dimensional Imaging by Mobile C-Arm With Flat-Panel Detector
    Fujimori, Takahito
    Iwasaki, Motoki
    Nagamoto, Yukitaka
    Kashii, Masafumi
    Takao, Masaki
    Sugiura, Tsuyoshi
    Yoshikawa, Hideki
    [J]. CLINICAL SPINE SURGERY, 2017, 30 (01): : E64 - E75
  • [4] Clinical Applications of Quantitative Perfusion Imaging with a C-Arm Flat-Panel Detector-A Systematic Review
    Al-Kaylani, Abdallah H. A. Zaid
    Schuurmann, Richte C. L.
    Maathuis, Wouter D.
    Slart, Riemer H. J. A.
    De Vries, Jean-Paul P. M.
    Bokkers, Reinoud P. H.
    [J]. DIAGNOSTICS, 2023, 13 (01)
  • [5] Experimental study of intracranial hematoma detection with flat panel detector C-arm CT
    Arakawa, H.
    Marks, M. P.
    Do, H. M.
    Bouley, D. M.
    Strobel, N.
    Moore, T.
    Fahrig, R.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (04) : 766 - 772
  • [6] Volume-of-interest, (VOI) imaging in C-arm flat-detector CT for high image quality at reduced dose
    Kolditz, Daniel
    Kyriakou, Yiannis
    Kalender, Willi A.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 2719 - 2730
  • [7] Low Dose, Low Noise and High Resolution Volume of Interest (VOI) Imaging in C-Arm Flat-Detector CT
    Kolditz, Daniel
    Kyriakou, Yiannis
    Kalender, Willi A.
    [J]. MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [8] C-Arm Cone-Beam Computed Tomography with a flat panel detector for intraoperative renal imaging assessment of image quality
    Burks, Frank N.
    Sebastion, Evelyn L.
    Kim, Leonard H.
    Gonzalez, Jose A.
    Martinez, Alvaro A.
    Kernen, Kenneth M.
    Hafron, Jason M.
    [J]. JOURNAL OF UROLOGY, 2008, 179 (04): : 679 - 680
  • [9] C-arm CT soft tissue 3-D imaging with a mobile C-arm
    Ritter, D
    Mitschke, M
    Graumann, R
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 3 - 6
  • [10] C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology
    Kamran, Mudassar
    Nagaraja, Sanjoy
    Byrne, James V.
    [J]. NEURORADIOLOGY, 2010, 52 (04) : 319 - 327