Comparison of three different chemiluminescence assays and a rapid liquid chromatography tandem mass spectrometry method for measuring serum aldosterone

被引:16
|
作者
Yin, Yicong [1 ,2 ]
Ma, Chaochao [1 ,2 ]
Yu, Songlin [1 ,2 ]
Liu, Wenjing [3 ]
Wang, Danchen [1 ,2 ]
You, Tingting [1 ,2 ]
Cheng, Qian [1 ,2 ]
Qiu, Ling [1 ,2 ]
机构
[1] Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Clin Lab, Beijing 100730, Peoples R China
[2] Chinese Acad Med Sci, Beijing 100730, Peoples R China
[3] Waters Corp Shanghai Sci & Technol Co Ltd, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
aldosterone; chemiluminescence immunoassay; liquid chromatography tandem mass spectrometry; inconsistency; primary aldosteronism; recalibration; PRIMARY HYPERALDOSTERONISM; IMMUNOASSAY; PLASMA; PREVALENCE; OUTCOMES;
D O I
10.1515/cclm-2019-0706
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: This study aimed to quantify and compare serum aldosterone (sALD) levels through three different chemiluminescence immunoassays (CLIAs) and liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis. Methods: Serum samples from 221 patients with suspected primary aldosteronism (PA) were retrospectively included in this study conducted at the Peking Union Medical College Hospital from June to August in 2017. sALD levels were determined using the LC-MS/MS method and three different CLIA systems, viz., DiaSorin (R) XL, iSYS and Auto Lumo A2000. Pooled fresh serum samples were used for recalibration. Passing-Bablok regression analysis, correlation matrix, and Bland-Altman plots were used to evaluate the concurrence among ALD levels determined using the three CLIAs. Results: Within-laboratory precision of the four assays ranged from 2.1% to 9.4%, except the coefficient variation (CV) of one of the CLIAs, which exceeded 20.0% for samples with low sALD levels. sALD levels determined using LC-MS/MS were significantly lower than those determined using the other three CLIAs (p <0.0001). Spearman's correlation coefficient of the four assays ranged from 0.745 to 0.950 (p < 0.0001). The Bland-Altman plot showed that the average bias WO for the three CLIAs and LC-MS/MS ranged from -69.3 to -49.2. After recalibration, this correlation did not improve among the assays. However, the bias and bias percentage at the medical decision level improved between LC-MS/MS and DiaSorin (R) XL/iSYS. Conclusions: Significant inconsistencies between the results of CLIAs and LC-MS/MS indicate that different sALD measures cannot be used interchangeably.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 50 条
  • [31] Serum testosterone in females by liquid chromatography tandem mass spectrometry
    Boyder, C.
    Joseph, J.
    Lim, E. M.
    Tanner, M.
    CLINICA CHIMICA ACTA, 2010, 411 (11-12) : 902 - 902
  • [32] Quantification of serum caspofungin by liquid chromatography tandem mass spectrometry
    Streit, F
    Cremer, S
    Schüttrumpf, S
    Ohmstede, B
    Binder, C
    Oellerich, M
    Binder, L
    THERAPEUTIC DRUG MONITORING, 2005, 27 (02) : 255 - 255
  • [33] Comparison of three different plasma homocysteine assays with gas chromatography-mass spectrometry
    Ubbink, JB
    Delport, R
    Riezler, R
    Vermaak, WJH
    CLINICAL CHEMISTRY, 1999, 45 (05) : 670 - 675
  • [34] Rapid quantification of bile acids and their conjugates in serum by liquid chromatography-tandem mass spectrometry
    Scherer, Max
    Gnewuch, Carsten
    Schmitz, Gerd
    Liebisch, Gerhard
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (30): : 3920 - 3925
  • [35] The establishment of a method for serum glycated albumin based on liquid chromatography/tandem mass spectrometry
    任文华
    ChinaMedicalAbstracts(InternalMedicine), 2017, 34 (04) : 194 - 194
  • [36] A rapid and reliable method for the quantitation of hydroxychloroquine in serum using turbulent flow liquid chromatography-tandem mass spectrometry
    Fuezery, Anna K.
    Breaud, Autumn R.
    Emezienna, Nkechinyere
    Schools, Sabitha
    Clarke, William A.
    CLINICA CHIMICA ACTA, 2013, 421 : 79 - 84
  • [37] A rapid and simple liquid chromatography-tandem mass spectrometry method for the measurement of testosterone, androstenedione, and dehydroepiandrosterone in human serum
    Xu, Wenjuan
    Li, Huijun
    Guan, Qing
    Shen, Ying
    Cheng, Liming
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2017, 31 (05)
  • [38] A rapid and precise method for quantification of fatty acids in human serum cholesteryl esters by liquid chromatography and tandem mass spectrometry
    Yu, Songlin
    Dong, Jun
    Zhou, Weiyan
    Yang, Ruiyue
    Li, Hongxia
    Zhao, Haijian
    Zhang, Tianjiao
    Guo, Hanbang
    Wang, Shu
    Zhang, Chuanbao
    Chen, Wenxiang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 960 : 222 - 229
  • [39] An improved method for measuring metaldehyde in surface water using liquid chromatography tandem mass spectrometry
    Schumacher, Melanie
    Castle, Glenn
    Gravell, Anthony
    Mills, Graham A.
    Fones, Gary R.
    METHODSX, 2016, 3 : 188 - 194
  • [40] A simple liquid chromatography-tandem mass spectrometry method for measuring metanephrine and normetanephrine in urine
    Gabler, Jessica
    Miller, Abby
    Wang, Sihe
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (07) : 1213 - 1216