A rapid and reliable method for the quantitation of hydroxychloroquine in serum using turbulent flow liquid chromatography-tandem mass spectrometry

被引:37
|
作者
Fuezery, Anna K. [1 ]
Breaud, Autumn R. [1 ]
Emezienna, Nkechinyere [1 ]
Schools, Sabitha [1 ]
Clarke, William A. [1 ]
机构
[1] Johns Hopkins Univ, Dept Pathol, Baltimore, MD 21287 USA
关键词
Hydroxychloroquine; Serum; Turbulent flow liquid chromatography; Mass spectrometry; SYSTEMIC-LUPUS-ERYTHEMATOSUS; LOW BLOOD-CONCENTRATION; RHEUMATOID-ARTHRITIS; MAJOR METABOLITES; HEALTHY-VOLUNTEERS; BIOLOGICAL-FLUIDS; STATIONARY PHASE; HUMAN-PLASMA; DESETHYLCHLOROQUINE; CHLOROQUINE;
D O I
10.1016/j.cca.2013.02.018
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Hydroxychloroquine is routinely used in managing systemic lupus erythematosus and rheumatoid arthritis. Whole blood levels are currently measured in the laboratory but at least one study suggests that serum levels may be equally useful. Moreover; serum samples are the preferred matrix type in the clinical laboratory as a result of their reduced complexity compared to whole blood. These observations suggest that the clinical utility of serum hydroxychloroquine levels needs to be reevaluated using larger studies and more robust assays. We report a turbulent flow LC-MS/MS method we developed for this purpose. Methods: After protein precipitation from serum with 033 mol/l perchloric acid, hydroxychloroquine and its deuterated analog were injected onto a Cyclone turbulent flow column for sample cleanup. Analytical separation was accomplished on a HypersilGold C8 column with a gradient of water and methanol, each containing 0.1% formic acid and 10 mmol/l ammonium formate. Analytes were ionized and detected by electrospray ionization mass spectrometry with multiple reaction monitoring. Results: Our method was linear from 15.7 to 2000 ng/ml. Total imprecision at multiple levels was <5% and accuracy was within +/- 15%. The method showed minimal carryover. Our extraction efficiency was 103% and the matrix factor was 101%. Comparison with a reference laboratory method identified constant bias but good correlation between the 2 methods. Conclusions: We present a novel turbulent flow liquid chromatography-tandem mass spectrometry method for quantification of hydroxychloroquine in serum. Our method has comparable sensitivity, selectivity, precision, accuracy, and linearity to previously reported methods. However, it offers simpler sample processing, shorter overall analysis time, and minimal carryover. These characteristics make our method well-suited for efficient analysis of the large number of samples necessary for studies on the clinical utility of serum HQ levels. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 50 条
  • [1] A rapid and fully-automated method for the quantitation of tricyclic antidepressants in serum using turbulent-flow liquid chromatography-tandem mass spectrometry
    Breaud, Autumn R.
    Harlan, Robert
    Di Bussolo, Joseph M.
    McMillin, Gwendolyn A.
    Clarke, William
    [J]. CLINICA CHIMICA ACTA, 2010, 411 (11-12) : 825 - 832
  • [2] Mucopolysaccharides quantitation in serum by liquid chromatography-tandem mass spectrometry
    Raymond, Kimiyo
    Lacey, Jean M.
    Dimitar, Gavrilov
    Matern, Dietrich
    Oglesbee, Devin
    Rinaldo, Piero
    Tortorelli, Silvia
    [J]. MOLECULAR GENETICS AND METABOLISM, 2018, 123 (02) : S123 - S123
  • [3] The development and clinical validation of a turbulent-flow liquid chromatography-tandem mass spectrometric method for the rapid quantitation of docetaxel in serum
    Marzinke, Mark A.
    Breaud, Autumn R.
    Clarke, William
    [J]. CLINICA CHIMICA ACTA, 2013, 417 : 12 - 18
  • [4] Method development and validation for rapid quantification of hydroxychloroquine in human blood using liquid chromatography-tandem mass Spectrometry
    Wang, Ling-Zhi
    Ong, Rina Yue-Ling
    Chin, Tan-Min
    Thuya, Win-Lwin
    Wan, Seow-Ching
    Wong, Andrea Li-Ann
    Chan, Sui-Yung
    Ho, Paul C.
    Goh, Boon-Cher
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 61 : 86 - 92
  • [5] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the quantitation of domperidone in human plasma
    Smit, MJ
    Sutherland, FCW
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    Els, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 949 (1-2) : 65 - 70
  • [6] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the quantitation of colchicine in human plasma
    Jiang, Yao
    Wang, Jiang
    Wang, Yingwu
    Li, Hao
    Fawcett, J. Paul
    Gu, Jingkai
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2): : 564 - 568
  • [7] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the quantitation of levodropropizine in human plasma
    Tang, YB
    Zhao, LM
    Wang, YW
    Fawcett, JP
    Gu, JK
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 819 (01): : 185 - 189
  • [8] Ocrelizumab quantitation by liquid chromatography-tandem mass spectrometry
    Hallin, Erik I.
    Serkland, Trond Traetteberg
    Myhr, Kjell-Morten
    Torkildsen, Oivind Grytten
    Skrede, Silje
    [J]. JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB, 2022, 25 : 53 - 60
  • [9] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the determination of leuprolide in human serum
    Zhan, Yan
    Chen, Xiaoyan
    Zhao, Xiaohua
    Zhong, Dafang
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (27): : 3194 - 3200
  • [10] A Rapid Method to Determine Tetrabromobisphenol A in Rat Serum and Urine by Liquid Chromatography-Tandem Mass Spectrometry
    Kang, Mi Jeong
    Kim, Ju Hyun
    Lee, Sang Kyu
    Kang, Wonku
    Kim, Hyung Sik
    Lyoo, Won Seok
    Jeong, Tae Cheon
    [J]. ARCHIVES OF PHARMACAL RESEARCH, 2010, 33 (11) : 1797 - 1803