A rapid and simple liquid chromatography-tandem mass spectrometry method for the measurement of testosterone, androstenedione, and dehydroepiandrosterone in human serum

被引:9
|
作者
Xu, Wenjuan [1 ]
Li, Huijun [1 ]
Guan, Qing [1 ]
Shen, Ying [1 ]
Cheng, Liming [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Lab Med, Wuhan, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
clinical application; LC-MS; MS; quantification; serum; steroid; SOLID-PHASE EXTRACTION; LC-MS/MS; REFERENCE INTERVALS; GAS-CHROMATOGRAPHY; STEROIDS; HORMONES; PLASMA; DHEA; 17-ALPHA-HYDROXYPROGESTERONE; DELTA-4-ANDROSTENEDIONE;
D O I
10.1002/jcla.22102
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BackgroundThe assay of androgens plays an important role for the differential diagnosis of androgen-related endocrine diseases. We developed a rapid and simple liquid chromatography tandem mass spectrometry (LC-MS/MS) method with small sample volume and simple sample preparation for simultaneous determination of serum testosterone, androstenedione and dehydroepiandrosterone (DHEA) in adults. MethodsWe spiked 100L of serum with 200L of internal standard solution, which was prepared in methanol, for matrix effect relief and protein precipitation. The obtained supernatant was used directly for LC-MS/MS analysis. ResultsThe validated method exhibits excellent linearity for each analyte withlinear correlation coefficient above 0.992. The total precisions at three concentrations were 15.66%, 8.81% and 4.34% for testosterone, 13.60%, 6.62% and 5.96% for androstenedione, 14.35%, 15.34% and 13.92% for DHEA, respectively. Recovery, carryover, matrix effect and analytical specificity were also performed for well validation of this LC-MS/MS method with satisfied results. Reference intervals (5th-95th centile) were also established for adult men and women. DiscussionThis method offers simpler implement for quantification of steroids in clinical laboratories with minimal manual sample manipulation and minimized sample volume requirements. ConclusionIt is demonstrated that a reliable, simple, sensitive and potential method for steroids assay in clinical laboratories had been successfully developed by LC-MS/MS.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Simultaneous determination of androstenedione and testosterone in human serum by liquid chromatography-tandem mass spectrometry
    Gallagher, L. M.
    Owen, L. J.
    Keevil, B. G.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2007, 44 : 48 - 56
  • [2] Liquid Chromatography-Tandem Mass Spectrometry Assay for Androstenedione, Dehydroepiandrosterone, and Testosterone with Pediatric and Adult Reference Intervals
    Kushnir, Mark M.
    Blamires, Takara
    Rockwood, Alan L.
    Roberts, William L.
    Yue, Bingfang
    Erdogan, Evrim
    Bunker, Ashley M.
    Meikle, A. Wayne
    CLINICAL CHEMISTRY, 2010, 56 (07) : 1138 - 1147
  • [3] A direct assay for the routine measurement of testosterone, androstenedione, dihydrotestosterone and dehydroepiandrosterone by liquid chromatography tandem mass spectrometry
    Owen, Laura J.
    Wu, Frederick C.
    Buttler, Rahel M.
    Keevil, Brian G.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2016, 53 (05) : 580 - 587
  • [4] Development of a method for the measurement of dehydroepiandrosterone sulphate by liquid chromatography-tandem mass spectrometry
    Chadwick, CA
    Owen, LJ
    Keevil, BG
    ANNALS OF CLINICAL BIOCHEMISTRY, 2005, 42 : 468 - 474
  • [5] Simultaneous Measurement of Serum Testosterone and Dihydrotestosterone by Liquid Chromatography-Tandem Mass Spectrometry
    Shiraishi, Steve
    Lee, Paul W. N.
    Leung, Andrew
    Goh, Victor H. H.
    Swerdloff, Ronald S.
    Wang, Christina
    CLINICAL CHEMISTRY, 2008, 54 (11) : 1855 - 1863
  • [6] Liquid chromatography-tandem mass spectrometry assay for human serum testosterone and trideuterated testosterone
    Starcevic, B
    Distefano, E
    Wang, C
    Catlin, DH
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (02): : 197 - 204
  • [7] Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry
    Turpeinen, U.
    Linko, S.
    Itkonen, O.
    Hamalainen, E.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2008, 68 (01): : 50 - 57
  • [8] Comparison of Immunoassay and Liquid Chromatography-Tandem Mass Spectrometry Methods in the Measurement of Serum Androstenedione Levels
    Yucel, Kamile
    Abusoglu, Sedat
    Unlu, Ali
    CLINICAL LABORATORY, 2018, 64 (1-2) : 69 - 75
  • [9] Measurement of tamsulosin in human serum by liquid chromatography-tandem mass spectrometry
    Upreti, Rita
    Homer, Natalie Z. M.
    Naredo, Gregorio
    Cobice, Diego F.
    Hughes, Katherine A.
    Stewart, Laurence H.
    Walker, Brian R.
    Andrew, Ruth
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 930 : 121 - 128
  • [10] Clinical Usefulness of Ultraperformance Liquid Chromatography-Tandem Mass Spectrometry Method for Low Serum Testosterone Measurement
    Cho, Sung-Eun
    Han, Jungsun
    Park, Ju-Hee
    Park, Euna
    Kim, Geun Young
    Lee, Jun Hyung
    Yi, Ahram
    Lee, Sang Gon
    Lee, Eun Hee
    Yun, Yeo-Min
    ANNALS OF LABORATORY MEDICINE, 2023, 43 (01) : 19 - +