Comparison of three different chemiluminescence assays and a rapid liquid chromatography tandem mass spectrometry method for measuring serum aldosterone

被引:16
|
作者
Yin, Yicong [1 ,2 ]
Ma, Chaochao [1 ,2 ]
Yu, Songlin [1 ,2 ]
Liu, Wenjing [3 ]
Wang, Danchen [1 ,2 ]
You, Tingting [1 ,2 ]
Cheng, Qian [1 ,2 ]
Qiu, Ling [1 ,2 ]
机构
[1] Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Clin Lab, Beijing 100730, Peoples R China
[2] Chinese Acad Med Sci, Beijing 100730, Peoples R China
[3] Waters Corp Shanghai Sci & Technol Co Ltd, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
aldosterone; chemiluminescence immunoassay; liquid chromatography tandem mass spectrometry; inconsistency; primary aldosteronism; recalibration; PRIMARY HYPERALDOSTERONISM; IMMUNOASSAY; PLASMA; PREVALENCE; OUTCOMES;
D O I
10.1515/cclm-2019-0706
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: This study aimed to quantify and compare serum aldosterone (sALD) levels through three different chemiluminescence immunoassays (CLIAs) and liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis. Methods: Serum samples from 221 patients with suspected primary aldosteronism (PA) were retrospectively included in this study conducted at the Peking Union Medical College Hospital from June to August in 2017. sALD levels were determined using the LC-MS/MS method and three different CLIA systems, viz., DiaSorin (R) XL, iSYS and Auto Lumo A2000. Pooled fresh serum samples were used for recalibration. Passing-Bablok regression analysis, correlation matrix, and Bland-Altman plots were used to evaluate the concurrence among ALD levels determined using the three CLIAs. Results: Within-laboratory precision of the four assays ranged from 2.1% to 9.4%, except the coefficient variation (CV) of one of the CLIAs, which exceeded 20.0% for samples with low sALD levels. sALD levels determined using LC-MS/MS were significantly lower than those determined using the other three CLIAs (p <0.0001). Spearman's correlation coefficient of the four assays ranged from 0.745 to 0.950 (p < 0.0001). The Bland-Altman plot showed that the average bias WO for the three CLIAs and LC-MS/MS ranged from -69.3 to -49.2. After recalibration, this correlation did not improve among the assays. However, the bias and bias percentage at the medical decision level improved between LC-MS/MS and DiaSorin (R) XL/iSYS. Conclusions: Significant inconsistencies between the results of CLIAs and LC-MS/MS indicate that different sALD measures cannot be used interchangeably.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 50 条
  • [21] Development of a rapid liquid chromatography tandem mass spectrometry method for the quantitation of serum dexamethasone and its clinical verification
    Hawley, James M.
    Owen, Laura J.
    Debono, Miguel
    Newell-Price, John
    Keevil, Brian G.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2018, 55 (06) : 665 - 672
  • [22] Development and validation of a rapid liquid chromatography/tandem mass spectrometry method to quantitate gabapentin and buprenorphine in human serum
    Phillips, Sarah J.
    Oliveto, Alison
    Mancino, Michael J.
    Hendrickson, Howard P.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (14)
  • [23] Rapid determination of serum testosterone by liquid chromatography-isotope dilution tandem mass spectrometry and a split sample comparison with three automated immunoassays
    Chen, Yu
    Yazdanpanah, Mehrdad
    Hoffman, Barry R.
    Diamandis, Eleftherios P.
    Wong, Pui-Yuen
    CLINICAL BIOCHEMISTRY, 2009, 42 (06) : 484 - 490
  • [24] Sensitive, Rapid and Easy Analysis of Three Catecholamine Metabolites in Human Urine and Serum by Liquid Chromatography Tandem Mass Spectrometry
    Fang, Lanyun
    Lv, Yan
    Sheng, Xuefei
    Yao, Shanshan
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2012, 50 (05) : 450 - 456
  • [25] Harmonization of Liquid Chromatography-Tandem Mass Spectrometry Protein Assays
    Rockwood, Alan L.
    Lowenthal, Mark S.
    Bystrom, Cory
    CLINICS IN LABORATORY MEDICINE, 2018, 38 (03) : 499 - +
  • [26] Optimization of a rapid method for screening drugs in blood by liquid chromatography tandem mass spectrometry
    Valero, Alba M. Rodrigo
    Jorge, Oscar Quintela
    Serrano, Begona Bravo
    Tejedor, Sara Ayuso
    ADVANCES IN LABORATORY MEDICINE-AVANCES EN MEDICINA DE LABORATORIO, 2023, 4 (04): : 365 - 371
  • [27] Method Optimization for Rapid Measurement of Carbohydrates in Plasma by Liquid Chromatography Tandem Mass Spectrometry
    Duc-Toan Nguyen
    Yu, Jundong
    Mho, Sun-Il
    Lee, Hae-Lee
    Lee, Wonjae
    Yee, Sung-Tae
    Lee, Gwang
    Paik, Man-Jeong
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2013, 34 (05) : 1571 - 1574
  • [28] A rapid quantitative method of carisoprodol and meprobamate by liquid chromatography-tandem mass spectrometry
    Essler, Shannon
    Bruns, Kerry
    Frontz, Michael
    McCutcheon, J. Rod
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 908 : 155 - 160
  • [29] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for determination of monoethylglycinexylidide
    Streit, F
    Niedmann, PD
    Shipkova, M
    Armstrong, VW
    Oellerich, M
    CLINICAL CHEMISTRY, 2001, 47 (10) : 1853 - 1856
  • [30] Simple rapid method for quantification of antiretrovirals by liquid chromatography - tandem mass-spectrometry
    Volosov, A
    Alexander, C
    Ting, L
    Soldin, SJ
    CLINICAL BIOCHEMISTRY, 2002, 35 (02) : 99 - 103