Development of a rapid liquid chromatography tandem mass spectrometry method for the quantitation of serum dexamethasone and its clinical verification

被引:15
|
作者
Hawley, James M. [1 ]
Owen, Laura J. [1 ,2 ]
Debono, Miguel [3 ]
Newell-Price, John [3 ]
Keevil, Brian G. [1 ,2 ]
机构
[1] Manchester NHS Fdn Trust, Wythenshawe Hosp, Dept Clin Biochem, Manchester M23 9LT, Lancs, England
[2] Univ Manchester, Manchester Acad Heath Sci Ctr, Manchester, Lancs, England
[3] Univ Sheffield, Acad Unit Endocrinol, Sheffield, S Yorkshire, England
关键词
Dexamethasone; mass spectrometry; overnight dexamethasone suppression test; Cushing's syndrome; SUPPRESSION TEST; PRACTICE GUIDELINE; CUSHINGS-SYNDROME; HUMAN PLASMA; CORTISOL; PREDNISOLONE; SOCIETY; MS/MS; ASSAY;
D O I
10.1177/0004563218766566
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Measurement of serum dexamethasone during the overnight dexamethasone-suppression test has been recommended to reduce false-positive results when investigating Cushing's syndrome or increasingly commonly found adrenal incidentalomas. Despite this, there remains a paucity of well-validated dexamethasone methods currently available. Here, we describe the development of a rapid and sensitive liquid chromatography tandem mass spectrometry serum dexamethasone assay and verify its utility in a cohort of postmenopausal females. Method Isotopically labelled internal standard was added to samples prior to supported liquid extraction. Extracts were analysed using liquid chromatography tandem mass spectrometry in the positive electrospray ionization mode. Multiple reaction monitoring was used to detect dexamethasone and its corresponding internal standard transitions. Normal healthy postmenopausal women (n=95) were recruited and underwent an overnight dexamethasone suppression test, with serum dexamethasone and cortisol measurements at 09:00 after administration of oral dexamethasone 1 mg at 23:00 the night before. Results Mean intra- and inter-assay imprecision were 4.1% and 2.9%, respectively, for dexamethasone concentrations of 1.5, 6.0 and 12.0 nmol/L. Matrix effects were found to be negligible at 106-109% with recovery ranging from 96 to 100%. The limit of quantitation was 0.25 nmol/L, and structural analogue analysis proved the method to be robust against interferences. Applying a serum dexamethasone cut-off of >3.3 nmol/L was associated with a serum cortisol 50 nmol/L in 84/95 individuals. Conclusion We have developed a sensitive and robust liquid chromatography tandem mass spectrometry method for the quantitation of serum dexamethasone. The method can be used to identify false-positive results during the overnight dexamethasone suppression test or for pharmacokinetic studies.
引用
收藏
页码:665 / 672
页数:8
相关论文
共 50 条
  • [1] Method verification of serum methylmalonic acid by liquid chromatography tandem mass spectrometry
    Almutairi, F.
    Almutairi, M.
    Nasibah, F.
    [J]. CLINICA CHIMICA ACTA, 2024, 558
  • [2] Mucopolysaccharides quantitation in serum by liquid chromatography-tandem mass spectrometry
    Raymond, Kimiyo
    Lacey, Jean M.
    Dimitar, Gavrilov
    Matern, Dietrich
    Oglesbee, Devin
    Rinaldo, Piero
    Tortorelli, Silvia
    [J]. MOLECULAR GENETICS AND METABOLISM, 2018, 123 (02) : S123 - S123
  • [3] Simultaneous quantitation of dexamethasone palmitate and dexamethasone in human plasma by liquid chromatography/tandem mass spectrometry
    Yang, Yan
    Li, Hao
    Gao, Kan
    Liu, Mingyuan
    Sun, Yantong
    Yan, Tingting
    Fawcett, J. Paul
    Cui, Yimin
    Gu, Jingkai
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 119 - 124
  • [4] Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications
    Bhaskar, V. Vijaya
    Middha, Anil
    [J]. INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 2013
  • [5] A rapid and reliable method for the quantitation of hydroxychloroquine in serum using turbulent flow liquid chromatography-tandem mass spectrometry
    Fuezery, Anna K.
    Breaud, Autumn R.
    Emezienna, Nkechinyere
    Schools, Sabitha
    Clarke, William A.
    [J]. CLINICA CHIMICA ACTA, 2013, 421 : 79 - 84
  • [6] The development and clinical validation of a turbulent-flow liquid chromatography-tandem mass spectrometric method for the rapid quantitation of docetaxel in serum
    Marzinke, Mark A.
    Breaud, Autumn R.
    Clarke, William
    [J]. CLINICA CHIMICA ACTA, 2013, 417 : 12 - 18
  • [7] Development and Validation of a High-Performance Liquid Chromatography–Tandem Mass Spectrometry Method for Methotrexate Quantitation in Human Serum
    Mohd Salleh Rizal Husaini Razali
    Lay Kek Rofiee
    Kok Hoi Teh
    Hishamshah Mohd Teh
    Mohd Zaki Ibrahim
    [J]. Journal of Analytical Chemistry, 2020, 75 : 1335 - 1339
  • [8] Development and validation of a rapid liquid chromatography/tandem mass spectrometry method to quantitate gabapentin and buprenorphine in human serum
    Phillips, Sarah J.
    Oliveto, Alison
    Mancino, Michael J.
    Hendrickson, Howard P.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (14)
  • [9] Rapid liquid chromatography tandem mass spectrometry method for targeted quantitation of human performance metabolites in saliva
    McBride, Ethan M.
    Lawrence, Richard J.
    McGee, Kirstin
    Mach, Phillip M.
    Demond, Paul S.
    Busch, Michael W.
    Ramsay, John W.
    Hussey, Erika K.
    Glaros, Trevor
    Dhummakupt, Elizabeth S.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2019, 1601 : 205 - 213
  • [10] A RAPID AND SENSITIVE METHOD FOR THE QUANTITATION OF MONTELUKAST IN HUMAN PLASMA USING LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY
    Gunasakaran, S.
    Rao, Nageshwara
    Arunkumar, S.
    Olaganathan, A.
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2010, 1 (10): : 65 - 72