Comparison of three different chemiluminescence assays and a rapid liquid chromatography tandem mass spectrometry method for measuring serum aldosterone

被引:16
|
作者
Yin, Yicong [1 ,2 ]
Ma, Chaochao [1 ,2 ]
Yu, Songlin [1 ,2 ]
Liu, Wenjing [3 ]
Wang, Danchen [1 ,2 ]
You, Tingting [1 ,2 ]
Cheng, Qian [1 ,2 ]
Qiu, Ling [1 ,2 ]
机构
[1] Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Clin Lab, Beijing 100730, Peoples R China
[2] Chinese Acad Med Sci, Beijing 100730, Peoples R China
[3] Waters Corp Shanghai Sci & Technol Co Ltd, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
aldosterone; chemiluminescence immunoassay; liquid chromatography tandem mass spectrometry; inconsistency; primary aldosteronism; recalibration; PRIMARY HYPERALDOSTERONISM; IMMUNOASSAY; PLASMA; PREVALENCE; OUTCOMES;
D O I
10.1515/cclm-2019-0706
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: This study aimed to quantify and compare serum aldosterone (sALD) levels through three different chemiluminescence immunoassays (CLIAs) and liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis. Methods: Serum samples from 221 patients with suspected primary aldosteronism (PA) were retrospectively included in this study conducted at the Peking Union Medical College Hospital from June to August in 2017. sALD levels were determined using the LC-MS/MS method and three different CLIA systems, viz., DiaSorin (R) XL, iSYS and Auto Lumo A2000. Pooled fresh serum samples were used for recalibration. Passing-Bablok regression analysis, correlation matrix, and Bland-Altman plots were used to evaluate the concurrence among ALD levels determined using the three CLIAs. Results: Within-laboratory precision of the four assays ranged from 2.1% to 9.4%, except the coefficient variation (CV) of one of the CLIAs, which exceeded 20.0% for samples with low sALD levels. sALD levels determined using LC-MS/MS were significantly lower than those determined using the other three CLIAs (p <0.0001). Spearman's correlation coefficient of the four assays ranged from 0.745 to 0.950 (p < 0.0001). The Bland-Altman plot showed that the average bias WO for the three CLIAs and LC-MS/MS ranged from -69.3 to -49.2. After recalibration, this correlation did not improve among the assays. However, the bias and bias percentage at the medical decision level improved between LC-MS/MS and DiaSorin (R) XL/iSYS. Conclusions: Significant inconsistencies between the results of CLIAs and LC-MS/MS indicate that different sALD measures cannot be used interchangeably.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 50 条
  • [41] Rapid and sensitive liquid chromatography tandem mass spectrometry method for the quantification of ambroxol in human plasma
    Hu, Wanqun
    Xu, Yu
    Liu, Fei
    Liu, Aixiang
    Guo, Qingxiang
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (10) : 1108 - 1114
  • [42] Sensitive and rapid method to determine trimetazidine in human plasma by liquid chromatography/tandem mass spectrometry
    Gujarat University, Department of Chemistry, School of Sciences, Navrangpura, Ahmedabad 380 009, India
    不详
    Journal of AOAC International, 1600, 91 (03): : 562 - 571
  • [43] A Novel and Rapid Method to Determine Doxycycline in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry
    Krishna, A. Chaitanya
    Sathiyaraj, M.
    Saravanan, R. S.
    Chelladurai, R.
    Vignesh, R.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2012, 74 (06) : 541 - 548
  • [44] Rapid Underivatized Method for Quantitative Methylmalonic Acid by Liquid Chromatography-Tandem Mass Spectrometry
    Mak, Justin
    Wong, Beverly T.
    Kwan, Tony
    Le, Anthony
    Cowan, Tina M.
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2018, 3 (03): : 408 - 417
  • [45] Rapid and simple liquid chromatography tandem mass spectrometry method for the quantification of zidovudine in rat plasma
    Mudigonda, Koteshwara
    Jukanti, Raju
    Apte, Shashank S.
    Kishan, Veerabrahma
    Maurya, Santosh
    Kandikere, Vishwottam
    Nirogi, Ramakrishna
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (01) : 20 - 27
  • [46] Rapid determination of metformin in human plasma by liquid chromatography-tandem mass spectrometry method
    Chen, XY
    Gu, Q
    Qiu, F
    Zhong, DF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (02): : 377 - 381
  • [47] Sensitive and rapid method to determine trimetazidine in human plasma by liquid chromatography/tandem mass spectrometry
    Mistri, Hiren N.
    Jangid, Arvind G.
    Shrivastav, Pranav
    JOURNAL OF AOAC INTERNATIONAL, 2008, 91 (03) : 562 - 571
  • [48] Rapid liquid chromatography-tandem mass spectrometry method for quantification of ziprasidone in human plasma
    Al-Dirbashi, OY
    Aboul-Enein, HY
    Al-Odaib, A
    Jacob, M
    Rashed, MS
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (04) : 365 - 368
  • [49] A rapid and sensitive liquid chromatography/tandem mass spectrometry method for determination of docetaxel in human plasma
    Wang, LZ
    Goh, BC
    Grigg, ME
    Lee, SC
    Khoo, YM
    Lee, HS
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (14) : 1548 - 1552
  • [50] A liquid chromatography tandem mass spectrometry method for plasma glucagon
    Nguyen, Van Long
    Tuckwell, Phillip
    Ireland, Andrea
    Fitzpatrick, Michael
    ANALYTICAL BIOCHEMISTRY, 2023, 675