Plastic scintillation dosimetry and its application to radiotherapy

被引:151
|
作者
Beddar, A. S. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX 77030 USA
关键词
dosimetry; scintillators; scintillation detectors; fiberoptic detectors; radiotherapy detectors;
D O I
10.1016/j.radmeas.2007.01.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We present a review of the dosimetric characteristics and properties of plastic scintillation detectors when exposed to high-energy photon and electron beams. The detectors show many desirable qualities, including water equivalence, energy independence, reproducibility, dose linearity, resistance to radiation damage, and near temperature independence. Therefore, these detectors do not require the usual conversion and/or correction factors used for other commonly used detectors to convert the dosimeter reading to absorbed dose. Furthermore, due to their small detecting volume, plastic scintillation detectors exhibit excellent spatial resolution. One issue concerning detector performance is the radiation-induced light arising in the optical fibers that carry the scintillator output to a photomultiplier tube or photodiode. The radiation induced light produced in optical fibers could be a combination of Cerenkov emission, fluorescence or luminescence depending on the type of material of the fibers utilized. For pure fused silica optical fibers, this spurious light emission is predominantly due to Cerenkov. This is most easily resolved by subtracting the signals from two sets of optical fibers, one carrying the entire signal and the other carrying just the Cerenkov background. Finally, we present two applications for plastic scintillation detectors in clinical radiotherapy: stereotactic radiosurgery dosimetry and the quality assurance of Co-60 and high-energy therapy beams. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S124 / S133
页数:10
相关论文
共 50 条
  • [21] A high sensitivity plastic scintillation detector for in vivo dosimetry of LDR brachytherapy
    Therriault-Proulx, F.
    Beaulieu, L.
    Beddar, S.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S116 - S116
  • [22] Monte Carlo modeling of the influence of strong magnetic fields on the stem-effect in plastic scintillation detectors used in radiotherapy dosimetry
    Simiele, E.
    Viscariello, N.
    DeWerd, L.
    MEDICAL PHYSICS, 2021, 48 (03) : 1381 - 1394
  • [23] Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range
    Lessard, Francois
    Archambault, Louis
    Plamondon, Mathieu
    Despres, Philippe
    Therriault-Proulx, Francois
    Beddar, Sam
    Beaulieu, Luc
    MEDICAL PHYSICS, 2012, 39 (09) : 5308 - 5316
  • [24] Comment on 'Plastic scintillation dosimetry: comparison of three solutions for the Cerenkov challenge'
    Archambault, Louis
    Beaulieu, Luc
    Beddar, Sam A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (11): : 3661 - 3665
  • [25] Passively scattered proton beam entrance dosimetry with a plastic scintillation detector
    Wootton, Landon
    Holmes, Charles
    Sahoo, Narayan
    Beddar, Sam
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03): : 1185 - 1198
  • [26] Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapy
    Beaulieu, Luc
    Beddar, Sam
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (20): : R305 - R343
  • [27] Dosimetry in clinical static magnetic fields using plastic scintillation detectors
    Stefanowicz, S.
    Latzel, H.
    Lindvold, L. R.
    Andersen, C. E.
    Jaekel, O.
    Greilich, S.
    RADIATION MEASUREMENTS, 2013, 56 : 357 - 360
  • [28] The application of transit dosimetry to precision radiotherapy
    Hansen, VN
    Evans, PM
    Swindell, W
    MEDICAL PHYSICS, 1996, 23 (05) : 713 - 721
  • [29] Characterisation of a plastic scintillation detector to be used in a multicentre stereotactic radiosurgery dosimetry audit
    Dimitriadis, A.
    Patallo, I. Silvestre
    Billas, I.
    Duane, S.
    Nisbet, A.
    Clark, C. H.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 373 - 378
  • [30] Proton Therapy Dosimetry by Using the Scintillation of Glass and Plastic Bare Optical Fibers
    Darafsheh, A.
    Taleei, R.
    Kassaee, A.
    Finlay, J.
    MEDICAL PHYSICS, 2017, 44 (06)