Plastic scintillation dosimetry and its application to radiotherapy

被引:151
|
作者
Beddar, A. S. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX 77030 USA
关键词
dosimetry; scintillators; scintillation detectors; fiberoptic detectors; radiotherapy detectors;
D O I
10.1016/j.radmeas.2007.01.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We present a review of the dosimetric characteristics and properties of plastic scintillation detectors when exposed to high-energy photon and electron beams. The detectors show many desirable qualities, including water equivalence, energy independence, reproducibility, dose linearity, resistance to radiation damage, and near temperature independence. Therefore, these detectors do not require the usual conversion and/or correction factors used for other commonly used detectors to convert the dosimeter reading to absorbed dose. Furthermore, due to their small detecting volume, plastic scintillation detectors exhibit excellent spatial resolution. One issue concerning detector performance is the radiation-induced light arising in the optical fibers that carry the scintillator output to a photomultiplier tube or photodiode. The radiation induced light produced in optical fibers could be a combination of Cerenkov emission, fluorescence or luminescence depending on the type of material of the fibers utilized. For pure fused silica optical fibers, this spurious light emission is predominantly due to Cerenkov. This is most easily resolved by subtracting the signals from two sets of optical fibers, one carrying the entire signal and the other carrying just the Cerenkov background. Finally, we present two applications for plastic scintillation detectors in clinical radiotherapy: stereotactic radiosurgery dosimetry and the quality assurance of Co-60 and high-energy therapy beams. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S124 / S133
页数:10
相关论文
共 50 条
  • [31] Reply to the comment on: 'Plastic scintillation dosimetry: comparison of three solutions for the Cerenkov challenge'
    Liu, P. Z. Y.
    Suchowerska, N.
    Lambert, J.
    Abolfathi, P.
    McKenzie, D. R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (11): : 3667 - 3673
  • [32] An improved calibration procedure for accurate plastic scintillation dosimetry on an MR-linac
    van den Dobbelsteen, Madelon
    Lessard, Boby
    Cote, Benjamin
    Hackett, Sara L.
    Mugnes, Jean-Michel
    Therriault-Proulx, Francois
    Lambert-Girard, Simon
    Uijtewaal, Prescilla
    de Vries, Laurie J. M.
    Archambault, Louis
    Bosma, Tom
    van Asselen, Bram
    Raaymakers, Bas W.
    Fast, Martin F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (24):
  • [33] Plastic scintillation dosimetry for radiation therapy: minimizing capture of Cerenkov radiation noise
    Beddar, AS
    Suchowerska, N
    Law, SH
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (05): : 783 - 790
  • [34] Real-time scintillation array dosimetry for radiotherapy: The advantages of photomultiplier detectors
    Liu, Paul Z. Y.
    Suchowerska, Natalka
    Abolfathi, Peter
    McKenzie, David R.
    MEDICAL PHYSICS, 2012, 39 (04) : 1688 - 1695
  • [35] A feasibility study of novel plastic scintillation dosimetry with pulse-counting mode
    Ishikawa, M.
    Bengua, G.
    Sutherland, K. L.
    Hiratsuka, J.
    Katoh, N.
    Shimizu, S.
    Aoyama, H.
    Fujita, K.
    Yamazaki, R.
    Horita, K.
    Shirato, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07): : 2079 - 2092
  • [36] PHOSPHORUS ACTIVATION NEUTRON DOSIMETRY AND ITS APPLICATION TO AN 18-MV RADIOTHERAPY ACCELERATOR
    BADING, JR
    ZEITZ, L
    LAUGHLIN, JS
    MEDICAL PHYSICS, 1982, 9 (06) : 835 - 843
  • [37] THERMOLUMINESCENCE DOSIMETRY IN RADIOTHERAPY - APPLICATION IN A PION BEAM
    VALLEY, JF
    ATOMKERNENERGIE, 1976, 27 (03): : 197 - 200
  • [38] PET/CT image registration:: Preliminary tests for its application to clinical dosimetry in radiotherapy
    Banos-Capilla, M. C.
    Garcia, M. A.
    Bea, J.
    Pla, C.
    Larrea, L.
    Lopez, E.
    MEDICAL PHYSICS, 2007, 34 (06) : 1911 - 1917
  • [39] Monte Carlo application in radiation dosimetry and radiotherapy
    Ma, CM
    Jiang, SB
    Pawlicki, T
    Li, JS
    Deng, J
    Kapur, A
    Mora, G
    Lee, MC
    Mok, E
    Findley, D
    Boyer, AL
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2000, : 681 - 692
  • [40] THE APPLICATION OF EPR DOSIMETRY FOR RADIOTHERAPY AND RADIATION PROTECTION
    KUDYNSKI, R
    KUDYNSKA, J
    BUCKMASTER, HA
    APPLIED RADIATION AND ISOTOPES, 1993, 44 (06) : 903 - 906