Plastic scintillation dosimetry for radiation therapy: minimizing capture of Cerenkov radiation noise

被引:35
|
作者
Beddar, AS [1 ]
Suchowerska, N
Law, SH
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX 77030 USA
[2] Royal Prince Alfred Hosp, Dept Radiat Oncol, Sydney, NSW, Australia
[3] Univ Sydney, Australian Photon CRC Opt Fibre Technol Ctr, Sydney, NSW 2006, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2004年 / 49卷 / 05期
关键词
D O I
10.1088/0031-9155/49/5/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Over the last decade, there has been an increased interest in scintillation dosimetry using small water-equivalent plastic scintillators, because of their favourable characteristics when compared with other more commonly used detector systems. Although plastic scintillators have been shown to have many desirable dosimetric properties, as yet there is no successful commercial detector system of this type available for routine clinical use in radiation oncology. The main factor preventing this new technology from realizing its full potential in commercial applications is the maximization of signal coupling efficiency and the minimization of noise capture. A principal constituent of noise is Cerenkov radiation. This study reports the calculated capture of Cerenkov radiation by an optical fibre in the special case where the radiation is generated by a relativistic particle on the fibre axis and the fibre axis is parallel to the Cerenkov cone. The fraction of radiation captured is calculated as a function of the fibre core refractive index and the refractive index difference between the core and the cladding of the fibre for relativistic particles. This is then used to deduce the relative intensity captured for a range of fibre core refractive indices and fibre core-cladding refractive index differences. It is shown that the core refractive index has little effect on the amount of radiation captured compared to the refractive index difference. The implications of this result for the design of radiation therapy plastic scintillation dosimeters are considered.
引用
收藏
页码:783 / 790
页数:8
相关论文
共 50 条
  • [1] Cerenkov light capture in optical fibres used for radiation therapy dosimetry
    Suchowerska, N
    Law, S
    Lambert, J
    McKenzie, D
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S112 - S112
  • [2] Full Spectrum Cerenkov Correction for Plastic Scintillation Dosimetry
    Monajemi, T. T.
    MEDICAL PHYSICS, 2017, 44 (06) : 2988 - 2988
  • [3] Preliminary Evaluation of the Impact of Cerenkov Radiation in a Stemless Plastic Scintillation Detector
    Hupman, Michael
    Hill, Ian
    Syme, Alasdair
    Monajemi, Thalat
    MEDICAL PHYSICS, 2019, 46 (11) : 5390 - 5391
  • [4] Cerenkov free micro-dosimetry in the radiation therapy treatment
    Debnath, S. B. C.
    Fauquet, C.
    Ferre, M.
    Tallet, A.
    Goncalves, A.
    Tonneau, D.
    Darreon, J.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1349 - S1350
  • [5] Plastic scintillation dosimetry: comparison of three solutions for the Cerenkov challenge
    Liu, P. Z. Y.
    Suchowerska, N.
    Lambert, J.
    Abolfathi, P.
    McKenzie, D. R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (18): : 5805 - 5821
  • [6] RADIATION DOSIMETRY WITH SCINTILLATION DETECTORS
    BELCHER, EH
    BRITISH JOURNAL OF RADIOLOGY, 1953, 26 (309): : 455 - 464
  • [7] Fiber-optic Cerenkov radiation sensor for proton therapy dosimetry
    Jang, Kyoung Won
    Yoo, Wook Jae
    Shin, Sang Hun
    Shin, Dongho
    Lee, Bongsoo
    OPTICS EXPRESS, 2012, 20 (13): : 13907 - 13914
  • [8] Real-Time Volumetric Scintillation Dosimetry for Radiation Therapy
    Beddar, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3790 - 3790
  • [9] Water equivalent plastic scintillation detectors in radiation therapy
    Beddar, A. S.
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 1 - 6
  • [10] Comment on 'Plastic scintillation dosimetry: comparison of three solutions for the Cerenkov challenge'
    Archambault, Louis
    Beaulieu, Luc
    Beddar, Sam A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (11): : 3661 - 3665