Plastic scintillation dosimetry and its application to radiotherapy

被引:151
|
作者
Beddar, A. S. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX 77030 USA
关键词
dosimetry; scintillators; scintillation detectors; fiberoptic detectors; radiotherapy detectors;
D O I
10.1016/j.radmeas.2007.01.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We present a review of the dosimetric characteristics and properties of plastic scintillation detectors when exposed to high-energy photon and electron beams. The detectors show many desirable qualities, including water equivalence, energy independence, reproducibility, dose linearity, resistance to radiation damage, and near temperature independence. Therefore, these detectors do not require the usual conversion and/or correction factors used for other commonly used detectors to convert the dosimeter reading to absorbed dose. Furthermore, due to their small detecting volume, plastic scintillation detectors exhibit excellent spatial resolution. One issue concerning detector performance is the radiation-induced light arising in the optical fibers that carry the scintillator output to a photomultiplier tube or photodiode. The radiation induced light produced in optical fibers could be a combination of Cerenkov emission, fluorescence or luminescence depending on the type of material of the fibers utilized. For pure fused silica optical fibers, this spurious light emission is predominantly due to Cerenkov. This is most easily resolved by subtracting the signals from two sets of optical fibers, one carrying the entire signal and the other carrying just the Cerenkov background. Finally, we present two applications for plastic scintillation detectors in clinical radiotherapy: stereotactic radiosurgery dosimetry and the quality assurance of Co-60 and high-energy therapy beams. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S124 / S133
页数:10
相关论文
共 50 条
  • [41] Radiochromic Film Dosimetry and its Applications in Radiotherapy
    Williams, Matthew
    Metcalfe, Peter
    CONCEPTS AND TRENDS IN MEDICAL RADIATION DOSIMETRY, 2011, 1345 : 75 - +
  • [42] Application of a free parameter model to plastic scintillation samples
    Tarancon Sanz, Alex
    Kossert, Karsten
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 (01): : 124 - 131
  • [43] TrueBeam Small Field Dosimetry Using Commercial Plastic Scintillation and Other Stereotactic Detectors
    Pino, R.
    Therriault-Proulx, F.
    Wang, X.
    Yang, J.
    Beddar, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 323 - 323
  • [44] A novel tool for in vivo dosimetry in diagnostic and interventional radiology using plastic scintillation detectors
    Boivin, J.
    Beddar, S.
    Guillemette, M.
    Beaulieu, L.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 680 - 684
  • [45] Proton Beam Entrance Dosimetry with the Exradin W1 Plastic Scintillation Detector
    Wootton, L.
    Holmes, C.
    Sahoo, N.
    Beddar, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3727 - 3727
  • [46] Characterization of the plastic scintillation detector Exradin W2 for small field dosimetry
    Galavis, Paulina E.
    Hu, Lei
    Holmes, Shannon
    Das, Indra J.
    MEDICAL PHYSICS, 2019, 46 (05) : 2468 - 2476
  • [47] OPTICAL FILTERING AND SPECTRAL MEASUREMENTS OF RADIATION-INDUCED LIGHT IN PLASTIC SCINTILLATION DOSIMETRY
    DEBOER, SF
    BEDDAR, AS
    RAWLINSON, JA
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (07): : 945 - 958
  • [48] TOWARD A REAL-TIME IN VIVO DOSIMETRY SYSTEM USING PLASTIC SCINTILLATION DETECTORS
    Archambault, Louis
    Briere, Tina M.
    Poenisch, Falk
    Beaulieu, Luc
    Kuban, Deborah A.
    Lee, Andrew
    Beddar, Sam
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (01): : 280 - 287
  • [49] PSD (plastic scintillation detector) in vivo dosimetry in post-operative endometrial brachytherapy
    Herreros, A.
    Melo, J.
    Moutinho, L.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1606 - S1607
  • [50] APPLICATION OF THERMOLUMINESCENT PHOSPHORS IN DOSIMETRY PROBLEMS IN RADIOTHERAPY AND RADIOBIOLOGY
    NAYLOR, GP
    BRITISH JOURNAL OF RADIOLOGY, 1967, 40 (471): : 170 - &