A novel tool for in vivo dosimetry in diagnostic and interventional radiology using plastic scintillation detectors

被引:5
|
作者
Boivin, J. [1 ,2 ,3 ]
Beddar, S. [4 ]
Guillemette, M. [2 ,3 ,5 ]
Beaulieu, L. [1 ,2 ,3 ]
机构
[1] CHU Quebec, Dept Radiooncol & Axe Oncol, Ctr Rech, Quebec City, PQ, Canada
[2] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ, Canada
[3] Univ Laval, Ctr Rech Canc, Quebec City, PQ, Canada
[4] Univ Texas MD Anderson Canc Ctr, Houston, TX 77030 USA
[5] Inst Univ Cardiol & Pneumol Quebec, Quebec City, PQ, Canada
关键词
PSD; plastic scintillation detector; dosimetry; photodetector; interventional radiology;
D O I
10.1007/978-3-319-19387-8_167
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A plastic scintillation detector (PSD) has been developed and optimized to measure dose rate in real-time for low energy beams. The PSD is composed of a scintillating fiber coupled to a clear optical fiber transmitting the scintillator's light to a photodetector. A spectrometer was used to characterize the scintillator's spectrum under low and high energy exposures. Seven photodetectors were then evaluated to identify their operating range and potential applications. They comprise a photomultiplier tube (PMT), an avalanche photodiode, two passive diodes of which, and a set of three CCD cameras. The scintillator was exposed to low energy potential beams (120 kVp, 180 kVp, and 220 kVp) of an orthovoltage unit. The source-to-detector distance was varied to explore a broad dose rate range likely to be used in radiology and superficial treatment. Every detector could measure dose rate down to 10 mGy/s while keeping a relative standard deviation below 2 %. The CCD cameras were the less sensitive devices, but they allow multiple fibers to be read simultaneously. Among the photodetectors, the PMT was found to be the most sensitive detector with a relative standard deviation of less than 1 % at the lowest dose rate available. The PMT was then included in the PSD design for an in vivo study in interventional radiology where low dose rate sensitivity is essential. The PSD was located inside a plastic water phantom to measure skin and depth dose from 1 mm down to 24 cm. There was less than a 2 % difference between the PSD measured dose rate and the ion chamber reading located at the same depth. These results indicate that a broad range of photodetectors can be used in the PSD design, but low dose rate measurements require very sensitive devices such as a PMT.
引用
收藏
页码:680 / 684
页数:5
相关论文
共 50 条
  • [1] TOWARD A REAL-TIME IN VIVO DOSIMETRY SYSTEM USING PLASTIC SCINTILLATION DETECTORS
    Archambault, Louis
    Briere, Tina M.
    Poenisch, Falk
    Beaulieu, Luc
    Kuban, Deborah A.
    Lee, Andrew
    Beddar, Sam
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (01): : 280 - 287
  • [2] Advances in plastic scintillation detectors dosimetry
    Beaulieu, L.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S182 - S182
  • [3] Plastic Scintillation Detectors: Present Status and Their Application for Quality Assurance and in Vivo Dosimetry
    Beddar, S.
    Beaulieu, L.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [4] Characterization of MOSFET Detectors for in Vivo Dosimetry in Interventional Radiology and for Dose Reconstruction in Case of Accident
    Bassinet, C.
    Huet, C.
    Baumann, M.
    Etard, C.
    Rehel, J-L
    Boisserie, G.
    Debroas, J.
    Aubert, B.
    Clairand, I.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [5] CHARACTERIZATION OF MOSFET DETECTORS FOR IN VIVO DOSIMETRY IN INTERVENTIONAL RADIOLOGY AND FOR DOSE RECONSTRUCTION IN CASE OF OVEREXPOSURE
    Bassinet, Celine
    Huet, Christelle
    Baumann, Marion
    Etard, Cecile
    Rehel, Jean-Luc
    Boisserie, Gilbert
    Debroas, Jacques
    Aubert, Bernard
    Clairand, Isabelle
    HEALTH PHYSICS, 2013, 104 (04): : 379 - 384
  • [6] Results From a 5 Patient in Vivo Rectal Wall Dosimetry Study Using Plastic Scintillation Detectors
    Wootton, L.
    Kudchadker, R.
    Lee, A.
    Beddar, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 96 - 97
  • [7] Dosimetry in clinical static magnetic fields using plastic scintillation detectors
    Stefanowicz, S.
    Latzel, H.
    Lindvold, L. R.
    Andersen, C. E.
    Jaekel, O.
    Greilich, S.
    RADIATION MEASUREMENTS, 2013, 56 : 357 - 360
  • [8] Real-time in vivo rectal wall dosimetry using plastic scintillation detectors for patients with prostate cancer
    Wootton, Landon
    Kudchadker, Rajat
    Lee, Andrew
    Beddar, Sam
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : 647 - 660
  • [9] Patient dosimetry in diagnostic and interventional radiology: A practical approach using trigger levels
    Faulkner, K
    Ortiz-Lopez, P
    Vano, E
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 166 - 168
  • [10] TrueBeam Small Field Dosimetry Using Commercial Plastic Scintillation and Other Stereotactic Detectors
    Pino, R.
    Therriault-Proulx, F.
    Wang, X.
    Yang, J.
    Beddar, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 323 - 323